- 29 -
11. Optional Functions
11-1-1
Trigger Input
ARTCAM-MI-WOM series are designed with external trigger.
*External trigger function is not available on ARTCAM-1000MI-WOM and ARTCAM-1400MI-WOM series.
Trigger Input Circuit
R1 = 2.
4kΩ
R2 = 10kΩ
R2
TRIG
3.3V
Sensor
Camer
a
R1
BNC
PC814
FPGA