![ARTRAY ARTCAM-0134AR-BW-WOM-OP Instruction Booklet Download Page 9](http://html.mh-extra.com/html/artray/artcam-0134ar-bw-wom-op/artcam-0134ar-bw-wom-op_instruction-booklet_2978765009.webp)
- 9 -
5. Connect the Camera
5-1 How to connect a camera
5-2 Shutter Speed
Shutter speed can be changed on the standard viewer software ART-Viewer.
The shutter speed is set directly on the sensor register, so please refer to the following formulas for the real exposure
time.
Model
Method
0134AR-WOM Series
Range
:
1~16383(Exposure Time
:
1/26747~0.61 sec)
Exposure Time
=
(1280+108) × Shutter Value × 1/37.125 [μsec]
at 37.125MHz