- 17 -
10. Optional Functions
10-1 Trigger timing chart
t0
Input Pulse Width
Above 1ms
t1
Photo Coupler Delay
1~99μs (Subject to Input Pulse Voltage)
t2
Reset Time
320µs (Actual measurement value)
t3
Exposure Time
Subject to Shutter Speed Settings
t4
Frame Transfer
37ms
t5
Effective Trigger for next frame
Within 1μs
Trigger Input
TRIG Signal
Reset Time
1
st
Line
2
nd
Line
Last Line
Vertical Synchronization Signal
Image Transfer (USB)
Exposure Time
t0
t1
t5
t3
t4
t2