Protection and Reporting

The DMX512 output surge protection contains a sacrificial element that will fail after a certain 

number of protection events (see Specification on page 8). When this failure occurs, the output 

will short together all 3 terminals. 
Output short-circuit is monitored and reported by the product as follows: 

Indicator

Tally output

The bottom LED indicator shows the monitoring status as follows:  

 

y

OFF = The product is analysing the output or there is no DMX512 input

 

y

Green = DMX512 output is operating normally

 

y

Red = DMX512 output is short-circuit. This indicates that either there is a short-circuit on 

the DMX512 output or that the sacrifical protection has failed.

A tally output is provided to allow protection status to be monitored remotely. The tally output is 

open-collector allowing multiple products to connect to a single reporting signal.

The output is designed to drive 12 VDC at 5 mA without an additional external resistor. 

 

y

To drive 24 VDC add a 2k2 external resistor.

 

y

To drive 48 VDC add a 5k6 external resistor. 

The output is as follows:

 

y

Float = The product is analysing the output or there is no DMX512 input or DMX512 output 

is operating normally

 

y

Sink = DMX512 output is short-circuit. This indicates that either there is a short-circuit on 

the DMX512 output or that the sacrifical protection has failed.

Summary of Contents for railSplit uno

Page 1: ...Artistic Licence railSplit uno User Guide railSplit uno Version 1 0 User Guide ...

Page 2: ... inside the outer case of this product Always disconnect from the power supply when not in use Any specific IP rating where appropriate is given in the instructions Unless otherwise stated this product is designed for indoor use only If used outdoors it MUST be installed in an appropriate IP rated cabinet Do not allow this product to be exposed to rain or moisture Do not allow liquid to penetrate ...

Page 3: ... Connection Input terminate 9 Connection DMX512 input Connections Mounting Diagram The DMX512 input can also be used as a passive loop through connection allowing onward connection to other DMX512 devices If this feature is not required then the signal must be terminated The product contains an internal termination resistor This is enabled by fitting the internal jumper under the terminal guard It...

Page 4: ...d cable is reported with a front panel indicator and via the fault tally output see Connections diagram on page 3 Page 4 Key features y y Input optical isolation y y Bi directional outputs y y Optimized for electrically noisy environments y y Mains electrocution protection self healing on DMX512 input and output y y Surge protection sacrificial on all terminals y y Front panel fault indication y y...

Page 5: ...ope Earth Ground is called Earth in the USA Earth Ground is called Ground Circuit Description DMX512 Input Type Isolated Pin 1 Connects to internal isolated circuit No connection to Internal Logic Ground DMX512 Output Type PSU referenced Pin 1 Connected to Internal Logic Ground Internal Logic Ground Connected to power supply 0V If the selected PSU has a connection between Earth Ground and 0V the D...

Page 6: ...accept the wide range of legal DMX timings and data Fix mode cleans out any unusual or non standard timing and data before sending to the output This includes stripping out all non zero start codes including RDM forcing a 512 channel footprint and calming any timing jitter Indicators have the following meaning Top Data y y As above Middle Power y y Green Power y y Red I am fixing something Detaile...

Page 7: ...ort circuit This indicates that either there is a short circuit on the DMX512 output or that the sacrifical protection has failed A tally output is provided to allow protection status to be monitored remotely The tally output is open collector allowing multiple products to connect to a single reporting signal The output is designed to drive 12 VDC at 5 mA without an additional external resistor y ...

Page 8: ... n a y y Electrocution protection output is protected against continuous connection to 425 VAC self healing y y Surge protection sacrificial IDC 30 000A 8 20uS 1 operation IDC 20 000A 8 20uS 10 operations IDC 20A 10 1000uS 1500 operations DMX512 Input y y Mode Optically isolated y y Isolation 1 kV y y Electrocution protection Input Loop protected against continuous connection to 425 VAC self heali...

Page 9: ...EEE compliance scheme and will happily recycle any of our products that you at your expense return to us Due to our policy of continuing product improvement specifications are subject to change without notice Artistic Licence The Mould Making Workshop Soby Mews Bovey Tracey TQ13 9JG United Kingdom Telephone 44 0 20 8863 4515 Email Sales ArtisticLicence com Web www ArtisticLicence com Support Artis...

Reviews: