background image

 

Page 7 

 Rail-Switch II User Guide

Rail-Switch II Specification

Mechanical

 

y

Housing: DIN Rail Case

 

y

Material: Polycarbonate plastic, UL94-V0 

rated

 

y

Overall dimensions: 90 mm (H) x 88 mm 

(W) x 62 mm (D) 

 

y

Weight: 0.2 kg

 

y

Mounting:  35  mm  DIN  Rail  or  Surface 

Mount

 

y

Country of manufacture: UK 

Environmental

 

y

Operating temperature: 0°C to 40°C

 

y

Storage temperature: -10°C to +50°C

 

y

Operating  relative  humidity  (max):  80% 

non-condensing

 

y

IP rating: IP20 indoor use only

 

y

Certification: CE, WEEE, RoHS

 

y

Warranty: 2-year (return to base)

Power & Electrical

 

y

Input voltage: 9-24 VDC

 

y

Input  connector:  2-pin  pluggable  screw 

terminal (1 no.)

 

y

Input power (max): 10 W

 

y

Duty cycle: 100% @ 25°C

 

 

y

DC  fuse:  i

nternal resettable fuse for 

control electronics

DMX512 input

 

y

Input mode: Non-isolated  

 

y

Input ESD protection: 12 kV

 

y

Input voltage protection: +/- 80 V

Data Connection

 

y

3-pin Screw Terminal DMX Input (1 no.)

 

y

4-pin Screw Terminal DMX Loop / Term 

(1 no.)

LED Indication

 

y

Power / DMX / RDM / Preset / Test / RDM 

locate / Relay 

Configuration

 

y

Commissioner

, DMX Workshop

 

y

Configurable settings include:

 -

Start address (individual for each relay)

 -

Preset, data loss and test modes

Package Contents

 

y

Rail-Switch II

 

y

User guide

Ordering Info

 

y

Product code: Rail-Switch II 

Accessories (not included)

 

y

PSU-24-2-DR

Outputs

 

y

Type:  6  x  changeover  relay,  volt-free 

contacts  

 

y

Connectors: 3-pin screw terminals (6 no.)

 

y

Maximum switching voltage: 250 VAC

 

y

Maximum peak current: 8A

 

y

Rated load (AC1 non-inductive): 2,000 VA 

 

y

Rated load (AC15 inductive): 500 VA 

 

y

Rated load (Single phase motor): 0.37 kW 

 

y

Minimum load: 500mW 

 

y

Protection:  User  supplied  external 

protection

 

y

Isolation: 1 kV between relay contacts

Control

 

y

Input Protocols: DMX512, DMX512(1990), 

DMX512-A

 

y

RDM V1.0 (E1.20 - 2006 ESTA Standard)

Summary of Contents for Rail-Switch II

Page 1: ...Artistic Licence Rail Switch II User Guide Rail Switch II Version 5 6 User Guide...

Page 2: ...inside the outer case of this product Always disconnect from the power supply when not in use Any specific IP rating where appropriate is given in the instructions Unless otherwise stated this produc...

Page 3: ...ck 2 Data Blue 3 Data Red Circuit Description DMX512 Input including Loop Through Type Non isolated Pin 1 Connects to Internal Logic Ground Relay Outputs Isolated volt free Internal Logic Ground Conne...

Page 4: ...DMX controller y y Data loss and test modes y y DIN Rail or surface mount Power Rail Switch II is be powered from an external DC power supply 9 24 VDC It is recommended that a ferrite core be fitted...

Page 5: ...Relays 1 6 right hand side Blue Relay is energised This windows based application provides a convenient means of accessing the Rail Switch II configuration menus DMX Workshop can also be used for prod...

Page 6: ...for more than 2 5 seconds It can be selected to play one of the 8 presets or hold the last state If DMX returns the control is immediately returned Rail Switch II will also power up in this mode unti...

Page 7: ...SD protection 12 kV y y Input voltage protection 80 V Data Connection y y 3 pin Screw Terminal DMX Input 1 no y y 4 pin Screw Terminal DMX Loop Term 1 no LED Indication y y Power DMX RDM Preset Test R...

Page 8: ...ipment WEEE Artistic Licence is a member of a WEEE compliance scheme and will happily recycle any of our products that you at your expense return to us Safety Warning When Rail Switch II is used for h...