500-003111-000
4-8
CONTROL REGISTER
HEX
D04
D03
D02
D01
D00
SELECTED INPUT CHANNEL NUMBER
P2 (CSR D7 = 0)
P3
SINGLE-ENDED
(MODE = 2)*
DIFFERENTIAL
(MODE = 1)*
(CSR D7 = 1)
(MODE = 1)*
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
(00)**
(01)
(02)
(03)
(04)
(05)
(06)
(07)
(08)
(09)
(10)
(11)
(12)
(13)
(14)
(15)
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
Table 4.5.2-1. Analog Input Channel Selection
* MODE
D10
D9
D8
1
2
0
0
0
1
1
0
**If P2 is configured with a combination of single-ended and differential channels, the single-ended channels that
are indicated with a differential channel (in parentheses) are no longer available as inputs.
M3111/T4.5.2-1
4.5.3
Gain and Channel Selection Precedence
To prevent driving the amplifiers into saturation and thus reduce the
accuracy of the conversion, comply with one of the following methods when
changing the gain setting.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com