Ready LED 

After Power ON, Matrix 504 starts booting. Once system is boot up, 
the Ready LED will show solid green.    The Ready LED will be 
turned off after Matrix 504 received 

halt

 command. 

 

Link/Act  LED 

When Ethernet port are connected to the network, Link/Act will show 
solid green and if there is traffic in the Ethernet, this LED will flash 
 
 

Serial Port LED 

These four dual color LEDs indicate the data traffic at the serial ports.  
When RXD line is high then Green light is ON and when TXD line is 
high, Yellow light is ON.   

Serial Port

 

The four serial ports can be configured as RS-232, RS-422 or RS-
485 by software.  They use RJ45 connector and the pin 
assignment are shown as following table.  

  

 
 

 
 
 
 
 
 
 

 
Port 1: RS-232/422/485  
 

RS-232: RXD,TXD,RTS,CTS,DSR,DTR,DCD,GND 

 

RS-422: TXD+, TXD-,RXD+,RXD-,GND 

 

RS-485: DATA+,DATA-,GND 

Port 2/3/4:  
 

RS-232: RXD,TXD,RTS,CTS,DSR,DTR,DCD,GND 

 

RS-485: DATA+, DATA-, GND 

 

Serial Console Port: 

Serial console port is used for locally accessing Matrix 504 
system using RS-232 port.  The console port uses RJ45 connector 
and is next to Ethernet port.  Therefore please be careful to plug 
in the right connector 
 
Port 0: RS-232:RXD,TXD,GND  
 
 
 
 
 
 
 
 
 
 
Therefore you need to prepare or purchase the serial console 
cable (CB-RJ2CON-100) in order to use the serial console port .   
In addition to the serial console signal, the console RJ45 port also 
provides GPIO ( programmable I/O signal) function.  The GPIO 
port is CMOS  I/O and can be programmed as digital input or 
output.  Power up setting is digital input mode with 75K ohm pull 
up resistor. 
  
 

Console 

Power Connector

 

Connect the 9 to 48VDC power line to Matrix 504.  If the 
power is properly supply, the power LED will show a solid 
green color. 
 
 
 
 
 
 

Ethernet Port

 

The Ethernet Port use RJ45 connector 

  

 

 

 

 

Summary of Contents for Matrix 504

Page 1: ...mple programs Optional Accessory 1 CB RJ45F9 150 RJ45 to DB9 Female Cable 2 CB RJ2CON 100 Serial Console Cable 3 DK 35A DIN RAIL Mounting Kit 4 PWR 12V 1A 110 240VAC to 12VDC 1A Power Adaptor Matrix 5...

Page 2: ...TXD TXD RXD RXD GND RS 485 DATA DATA GND Port 2 3 4 RS 232 RXD TXD RTS CTS DSR DTR DCD GND RS 485 DATA DATA GND Serial Console Port Serial console port is used for locally accessing Matrix 504 system...

Page 3: ...lnet guest only Password root or guest telnet guest only Serial Console Port Baud rate 115200 Data format 8 Bits No Parity 1 Stop bit N 8 1 Flow Control None Terminal type VT100 Network Settings Use v...

Page 4: ...be index html Adjust the system time To adjust the RTC time you can follow the command date MMDDhhmmYYYY where MM Month 01 12 DD Date 01 31 hh Hour mm minutes YYYY Year hwclock w To write the date inf...

Page 5: ...it to execution mode and file o to run the program Auto start program on boot To start a program on boot you can use etc rc local For example to use vi to edit rc local guest hello exit 0 Hello will b...

Page 6: ...please repeatedly keying and you will see the loader menu appear as follow If you miss the timing please power on again the Matrix 504 and do it again Select U will prompt the run level selection mes...

Page 7: ...u want To install the utility from Artila ftp please use vi to edit the etc ipkg conf src gz arm ftp ftp ftp ftp artila com Matrix5xx tmp armv5te src gz kernel ftp ftp ftp ftp artila com Matrix5xx tmp...

Reviews: