User Manual explosion-safe AR-030 door magnet
5 / 6
Issue April 2020
9.
Maintenance
For the maintenance of the AR-030 door magnet the requirements as stated in EN 60079-17 apply.
If the door magnet or the connection cable is damaged or no longer in good condition it must be repaired immediately.
The power supply to the door magnet must be switched off and may only be restored after the maintenance has been
carried out and approved.
The door magnet must be cleaned if it is very dirty.
The advised maintenance cycle for this twilight switch depends on its specific use and must therefore be agreed upon
with the user for the expected use.
10.
Repair
Because of the molding of the electronics, none of the parts can be replaced.
If repairs are carried out in an incompetent manner, the explosion-safety of the door magnet can no longer be
guaranteed. Therefore it is preferred that the door magnet is returned to the manufacturer for repair.
11.
Removal / Re-use
The equipment can be completely processed as electronic waste. For processing regarding disposal or reuse of the
product and its packaging, national disposal and environmental laws and legislation must be taken into consideration.