User Manual explosion-safe AR-030 door magnet 

2 / 6 

Issue April 2020 

 

 

1.

 

Safety Instructions 

The AR-030 Door Magnet is an explosion-safe product suitable for use in hazardous areas with explosion hazard from 

flammable gasses, vapors and mist, classified as zone 2 of zone 22. 

 

This manual must be read and understood for safe use of the Door Magnet. All warnings and instructions must be 

followed. 

 

 

Installation must be carried out by personnel trained and qualified in explosion safety taking the instructions 

mentioned on the equipment and in this manual into consideration. Local regulations that apply to the installation 

must be followed.  

 

Only connect this equipment to the correct voltage and mains frequency for which it is designed.  

 

Isolate electrical power to the Door Magnet split unit before electrical installation. 

 

The plastic cover can be electrostatically charged. Only use a damp cloth to clean the cover. Do not use 

solvents.  

 

Either decommission the Door Magnet or do not use it when it is damaged.  

 

During installation of the Door Magnet national safety regulations must be observed.  

 

Only use the Door Magnet unit under the environmental conditions for which it is specified. Deviating 

environmental conditions can contribute to damage to the equipment and may lead to possible danger to the life 

of the user.  

 

Do not use the Door Magnet split unit at temperatures deviating from the specified ambient temperature range.  

 

Follow all instructions written on the equipment and as mentioned in this manual.  

 

Repairs may only be carried out by the manufacturer or by a person appointed by the manufacturer.  

 

Modifications to the equipment or changes to the design are not permitted.  

 

The product may only be used for the function for which it is designed and shall be maintained in a good and 

clean condition.  

 

If these instructions are not followed the explosion safety of the equipment cannot be guaranteed. The equipment 

could then endanger the life of the user and could cause the ignition of an explosive atmosphere. Consequently, Artidor 

as the manufacturer will waive any responsibility. 

 

2.

 

Description 

The explosion-safe AR-030 Door Magnet is a universally-applicable door magnet for floor or wall mounting.   

The magnetic head can easily be positioned horizontally or vertically. The Door Magnet is manufactured from impact-

resistant plastic with a vandal-proof release button and a factory sealed cable. The explosion safety to gas is arranged 

by the appliance of protection degree against ignition ‘increased safety‘. The explosion safety to dust is arranged by the 

appliance of protection degree against ignition ‘protected by enclosure’. 

 