Installation manual AR-024 explosion-safe occupancy sensor
04-2022
9 / 44
E
7.
Installation instructions
•
Installation of explosion-safe equipment such as this product must be carried out by
personnel specially trained and qualified to do this, following the relevant requirements
of the installation standard EN 60079-14.
•
For the installation and use of this product the relevant safety regulations and also the
generally recognized latest state of the technology apply.
•
During assembly, care must be taken that the framework, screws and surface are strong
enough to take the weight of the occupancy sensor.
•
Isolate power from the electrical supply cable prior to installation.
•
Install the connection cable and make sure that it is protected from mechanical and
chemical influences.
•
The occupancy sensor offers 8 connection terminals:
Power supply:
Potential free contact:
L
230 VAC
NO connection 1
N
Neutral
NO connection 2
PE
Protective earth
R
Connection for slave
S
Switch for semi-automatic mode
8.
Operating instructions
All setting can be done by use of the infrared remote control. The settings are explained in
the OEM manual that is supplied with the product.