background image

User Guide

Danish craftmanship 

Mediterranean soul

Technology Serving Design

DynamicX2Talk

HDCP compliant aluminium retractable motorised monitors 
with integrated independent microphone lift system

Summary of Contents for DynamicX2Talk

Page 1: ...User Guide Danish craftmanship Mediterranean soul Technology Serving Design DynamicX2Talk HDCP compliant aluminium retractable motorised monitors with integrated independent microphone lift system ...

Page 2: ......

Page 3: ...ETY INSTRUCTIONS 6 SYSTEM DESCRIPTION 8 DYNAMICTALK HANDLING 13 INPUT CONNECTORS 14 CONTROLS 17 OSD MENU 20 MONITOR AHnet PROTOCOL 23 DYNAMICTALK AHnet PROTOCOL 27 VIDEO SIGNALS 29 AHlink 30 INFORMATION ON DISPOSAL 35 WARRANTY TERMS AND CONDITIONS 36 ...

Page 4: ...rthur Holm product Please read these installation and operating instructions carefully and keep them in a safe place for future consultations We remain at your entire disposal if you have any suggestions Henrik Holm General Manager hholm albiral com ...

Page 5: ... based on quality materials and the latest technology Products which endow meeting and conference rooms with silent ergonomic innovative and aesthetic solutions that integrate into the furniture hang from the walls as works of art or are used as interactive points of information The world of Arthur Holm Arthur Holm offers a selection of unique elegant versatile flexible and ergonomic products that...

Page 6: ...y the cable used Do not place anything on the power cord Do not locate this product where a person may walk or trip over the cord REGULATIONS AND SECURITY ATTENTION Do not disassemble or modify the device in any way This symbol warns of the presence of dangerous un insulated voltages inside some of the components of sufficient magnitude to expose people to risk of electronic shock This symbol draw...

Page 7: ... the equipment to Rain or water Excessive heat cold or humidity Area exposed to direct sunlight Dirty areas Equipment generating strong magnetic fields Avoid placing open containers of liquid near the equipment Keep a minimum distance of 30 mm in order to have good ventilation Never place above the device any sources of flames such as lighted candles etc If you are using the device in extreme weat...

Page 8: ... the microphones protecting them making meeting and conference spaces more flexible and versatile This system has 2 different working modes PA and Conference In PA mode a push button activates and de activates the microphone while the LED ring will show the status changing from red to green The system will silence the microphone when retracting In Conference mode the microphone will be always acti...

Page 9: ...ss steel integrating a rounded microphone coverlid The system provides a patented 360 LED lighting to indicate microphone status AH22DX216GATalk HDCP compliant vertically retractable aluminium 21 5 Full HD monitor with 20 degrees of automatic inclination with an independent lift for gooseneck microphones Single engine patented mechanism Solid aluminium monitor in natural anodisation finish featuri...

Page 10: ...r AHTECB2 Min 10 units GPI remote control interface AHTECB2 Min 10 units GPI remote control interface MC Matte cover plate MC Matte cover plate TS170HD Projected capacitive multitouch screen TS2216G Projected capacitive multitouch screen USBC Min 10 units USB camera tilt USBC Min 10 units USB camera tilt HDSDIC Min 10 units HD SDI camera tilt HDSDIC Min 10 units HD SDI camera tilt CCUSBC USB passt...

Page 11: ...DMI retractable AHDL DynamicLoop AHDL DynamicLoop AHDSS DynamicShare AHDSS DynamicShare AHISBD2 HDMI retractable Share AHISBD2 HDMI retractable Share AHHC HDMI fixed Share AHHC HDMI fixed Share AHDSPB Priority AHDSPB Priority CABD2 Min 10 units Black anodised CABD2 Min 10 units Black anodised GFD2 Min 10 units Gold finish GFD2 Min 10 units Gold finish BFD2 Min 10 units Bronze finish BFD2 Min 10 un...

Page 12: ...ds one for the monitor and one for DynamicTalk Remote control 1 per 5 monitors Two power supplies 100 240Vac 50 60Hz Output 12V one for the monitor and one for DynamicTalk User guide Important note This device can only work with the power supply included in the shipping box This power supply can not be replaced by any other rather than the original one SYSTEM DESCRIPTION ...

Page 13: ...usage of the DynamicTalk microphones To avoid any product malfunctions do not attempt to bend the microphone to the incorrect angle or outside the microphone s working area as indicated on the picture below Please note that ware to the microphone and pop screen surface can occur ...

Page 14: ... last unit of the RS422 bus AHnet RJ45 CAT6 connector for addressable RS422 control There is a loop through connector to use as signal RS422 output Up to 30 monitors can be connected on the same RS422 bus DVI 1 DVI A DVI I input signal Connect a DVI digital input signal and select DVI 1 on the OSD monitor menu Use a DVI to VGA adaptor to connect an ARGB analogue input signal and select DVI A on th...

Page 15: ...number of the device into the RS422 addressable bus TERM OUT Brighting when the RS422 bus termination is active Active only the RS422 bus termination on the last unit of the bus RX Brights when the unit receives a RS422 AHNet command OSD OK Changing AHnet Address Press OK button Change the AHnet number address using and keys and press OK to save the new address RS422 bus termination Press key to a...

Page 16: ...DOWN connecting to GND Use a pulse signal to RISE and LOWER the microphone 4 Red LED ring brights connecting to GND only in conference mode 5 Green LED ring brights connecting to GND only in conference mode 6 GND 7 8 GPO1 Contact close of the central button located on cover plate 9 10 GPO2 Contact close of the Talk button located on cover plate SERVICE USB only for service 12V D C Power supply inp...

Page 17: ...address Below the monitor there is a screen to set up the monitor Press the UP or DOWN buttons to change the function Press the OK button to select the function Change the parameter using the UP or DOWN buttons and press OK again to save the changes AHNET ID Selects the number AHnet ID to RS422 to externally control the monitor INPUT SELECT Selects the input source signal DVIA DVI1 or DVI2 BRIGHTN...

Page 18: ...he DynamicTalk functions and to external control other devices GPO 1 Raising the monitor To rise up the monitor display press the button 1 on the right hand side of the cover plate Please make sure that no objects are located on top of the monitor 2 Retracting the monitor To retract the monitor display press the button 2 on the right hand side of the cover plate Please make sure that no objects ar...

Page 19: ...o talk to the audience Press the button again to activate de Mute function and silent the microphone which will be indicated by the green LED ring Conference mode In conference mode the microphone is controlled by the external conference system In this case this button then has no function and the contact close of the push button is present on the SubD9 control connector GPO In this case there are...

Page 20: ...r the monitor Press the OK button to confirm When a function is selected press the LEFT and RIGHT buttons in order to change the parameter of the function Press the MENU button to access to the main menu Picture Picture Mode Adjusts the mode of the image Dynamic Standard Mild User Contrast Brightness Colour Sharpness Tint Colour Temperature Adjusts the colour of the image Cool Medium Warm Use Red ...

Page 21: ...e image noise filter Off Low Medium High Default Screen Only for analogue signals Auto Adjust Horizontal Position Vertical Position Size Phase Backlight Adjusts the backlight screen s level Colour Range Adjusts the colour range 0 255 16 235 ...

Page 22: ...ters to the initial factory parameters Blending OSD window transparency Low Medium High Off OSD Duration Adjusts the time that the OSD menu window remains on the screen Software Update USB Port to use for firmware s upgrade Mirror 0 Image with no flip 1 Vertical flip 2 Horizontal flip 3 Rotate ...

Page 23: ... 3 Data RX 4 NC 5 NC 6 Data RX 7 NC 8 NC Connection PINS 1 2 The units respond PINS 3 6 The units receive instructions Protocol to control the monitor by addressable RS422 bus You can connect up to 30 monitors on the same RS422 bus You can use an AH ERT interface to control the RS422 bus The units should have a set address and the address must start by 1 Maximum cable length between ends 500 m 164...

Page 24: ...FB XX 02 01 00 FA XX 02 00 00 SCREEN OFF FB XX 02 00 00 FA XX 03 01 00 DVI A SELECTION FB XX 03 01 00 FA XX 03 00 00 DVI 1 SELECTION FB XX 03 00 00 FA XX 03 03 00 DVI 2 SELECTION FB XX 03 03 00 FA XX 04 01 00 BUTTON LOCK FB XX 04 01 00 FA XX 04 00 00 BUTTON UNLOCK FB XX 04 00 00 FA XX 14 00 00 INQUIRY CONTROL BYTE FB XX 14 CB1 CB2 XX Number of the monitor address Up to 30 monitors for each RS422 B...

Page 25: ...Hnet PROTOCOL CB1 BITE 7 6 5 4 3 2 1 0 CLOSED 1 1 0 1 OPENED 0 1 0 1 SCREEN ON 1 SCREEN OFF 0 DVI A 0 0 DVI 1 D 1 1 DVI 2 D 1 0 PROTECTION STOP 1 MONITOR OK 0 CB2 BITE 7 6 5 4 3 2 1 0 BUTTON LOCK 1 BUTTON UNLOCK 0 ...

Page 26: ...for each RS422 BUS ZZ Level of the function selected 00 99 Dec COMMAND DESCRIPTION RESPONSE FA XX 15 01 ZZ SET BACKLIGHT LEVEL FB XX 15 01 ZZ FA XX 16 01 ZZ SET CONTRAST LEVEL FB XX 16 01 ZZ FA XX 17 01 ZZ SET BRIGHTNESS LEVEL FB XX 17 01 ZZ XX Number of the monitor address Up to 30 monitors for each RS422 BUS ZZ Level of the function selected 00 99 Dec To send an order to all the monitors you mus...

Page 27: ...he unit by addressable RS422 bus You can connect up to 30 devices on the same RS422 bus You can use an AH Interface Ethernet to control the RS422 bus The units should have a set address and the address must start by 1 Maximum cable length between ends 500 m 1640 ft AHnet protocol Using 5 bytes communication BYTE 0 START BYTE BYTE 1 ADDRESS BYTE BYTE 2 COMMAND BYTE BYTE 3 VALUE 1 BYTE 4 VALUE 2 RJ ...

Page 28: ...XX 04 01 00 BUTTON UNLOCK FB XX 04 01 00 FA XX 14 00 00 INQUIRY CONTROL BYTE FB XX 14 CB1 CB2 XX Number of the DynamicTalk address Up to 30 units can be connected for each RS422 BUS CB1 Response in 8 bits of the device status CB2 Not implemented CB1 BITE 0 TOP POSITION BITE 1 DOWN POSITION BITE 2 1 MUTE ON BITE 3 1 BUTTON LOCK BITE 4 BITE 5 BITE 6 BITE 7 1 FAILURE IN THE SYSTEM To send an order to...

Page 29: ...0 75Hz 46 875 75 000 Progressive 1024x768 60Hz 48 363 60 005 Progressive 1024x768 70Hz 56 476 70 070 Progressive 1024x768 75Hz 60 023 75 030 Progressive 1280x720 60Hz 44 697 59 915 Progressive 1360x768 60Hz 47 396 59 995 Progressive 1280x1024 60Hz 63 981 60 020 Progressive 1600x1200 60Hz 74 479 59 967 Progressive 1680x1050 60Hz 65 160 59 944 Progressive 1920x1080 60Hz 67 500 60 000 Progressive ...

Page 30: ...Interactive Setup Display located under the monitor Press the Down key near the LCD Interactive Setup Display until the AHlink option appears Press the OK button to activate the AHlink signal on the unit When the AHlink signal is activated the sound of 5 beeps will indicate that the AHlink signal is active on the unit The wireless AHLink signal automatically deactivates when there is no device con...

Page 31: ... might no longer be active The AHLink name always begins with the characters AH followed by the four last MAC AHLink address You must select the AH device After selecting the AH device the first page will upload on your screen This page is used for the basic installation setup ...

Page 32: ...ness adjustments SAVE VALUES Memorises the backlight contrast and brightness values AHLINK OFF Turns off the AHlink signal COMMAND Information of the last AHnet command received from RS422 port SENSORS Indicates sensor status S1 indicates the screen is completely open AHNET ADDRESS Configuration of the AHnet address of the unit password POSITION Screen position Value 0 indicates that the screen is...

Page 33: ...tion to identify the unit connected BT OFF Switch off the AHlink signal on the device It will close the AHlink App connection AUTO ADJUST This function auto adjust the speed and mechanical protection of the unit The unit will starts to go automatically Up and Down in order to auto adjust the speed and the mechanical protection parameters RED GREEN OFF Controls the LED ring in conference mode COMMA...

Page 34: ...ctivate the RS422 termination only in the last unit of the RS422 Bus MODE Dynamic Talk working mode PA mode is used for standard XLR3 microphones the microphone is controlled by the Dynamic Talk and the LED ring indicates the state of the microphone green MUTE red TALK In conference mode the external conference system controls the microphone and the LED ring is controlled using the GPI connector P...

Page 35: ...ll help save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling Please contact your local authority for further details of your nearest designated collection point Penalties may be applicable for incorrect disposal of this waste in accordance with national legislation For business users in ...

Page 36: ...bour costs Albiral Display Solutions covers the labour costs to replace any defective parts during the validity of this warranty 5 Transport costs 5 1 In the case that a manufacturing defect occurs within 90 days after the purchase date both freight and insurance costs will be paid by Albiral Display Solutions Although Albiral Display Solutions S L pays for freight and insurance costs Albiral Disp...

Page 37: ...The beneficiary of the warranty will have to return the product with the original packaging to warranty there are no damages during transportation 10 The warranty is not valid if the beneficiary of the warranty does not include an RMA form and a copy of the purchasing invoice Please note that laws vary from country to country and the same provisions of this warranty may not apply to you If you hav...

Page 38: ......

Page 39: ...39 ...

Page 40: ...pòlit de Voltregà 08512 Barcelona Spain tel 34 93 850 23 76 23 83 fax 34 93 850 25 50 23 72 web www arthurholm com e mail marketing arthurholm com This manual can be modified without previous notice ENG November 2020 P27178ITEP P27178RUPC P27178USPC P27284DEEP P27284EPPC P27284ESEP P27284GBEP P27284RUPC P27284USPC P27715ESEP P28089DEEP P28089ESEP P28089ITEP P28089USPC P28090EP00 P31160ESES P31160P...

Reviews: