background image

User Guide

Danish craftmanship 

Mediterranean soul

Technology Serving Design

Dynamic1H

HDCP compliant aluminium foldable motorised monitors

Summary of Contents for Dynamic 1H

Page 1: ...User Guide Danish craftmanship Mediterranean soul Technology Serving Design Dynamic1H HDCP compliant aluminium foldable motorised monitors ...

Page 2: ...ATIONS AND SECURITY 5 SAFETY INSTRUCTIONS 5 SYSTEM DESCRIPTION 7 CONTROLS 11 OSD MENU 13 ISD MENU 16 INPUT CONNECTORS 22 AHnet PROTOCOL 24 VIDEO SIGNALS 28 AHLink 29 INFORMATION ON DISPOSAL 32 WARRANTY TERMS AND CONDITIONS 33 ...

Page 3: ...rthur Holm product Please read these installation and operating instructions carefully and keep them in a safe place for future consultations We remain at your entire disposal if you have any suggestions Henrik Holm General Manager hholm albiral com ...

Page 4: ... based on quality materials and the latest technology Products which endow meeting and conference rooms with silent ergonomic innovative and aesthetic solutions that integrate into the furniture hang from the walls as works of art or are used as interactive points of information The world of Arthur Holm Arthur Holm offers a selection of unique elegant versatile flexible and ergonomic products that...

Page 5: ...he power cord Do not locate this product where a person may walk or trip over the cord REGULATIONS AND SECURITY ATTENTION Do not disassemble or modify the monitor in any way This symbol warns of the presence of dangerous un insulated voltages inside some of the components of sufficient magnitude to expose people to risk of electronic shock This symbol draws attention to important use and maintenan...

Page 6: ...the equipment to Rain or water Excessive heat cold or humidity Area exposed to direct sunlight Dirty areas Equipment generating strong magnetic fields Avoid placing open containers of liquid near the equipment Keep a minimum distance of 30 mm in order to have good ventilation Never place above the monitor any sources of flames such as lighted candles etc If you are using the monitor in extreme wea...

Page 7: ...rt memory system enables both the set up and recall of the desired tilting position Built entirely of aluminium and with a black edged anti reflection glass Dynamic1H monitors are extremely elegant discreet and timeless Features Adjustable position Position memory Interactive Setup Display Maintenance free Energy saving design Safety system Serial control Remote diagnostic Wireless connectivity fo...

Page 8: ...itor housing and cover plate are made of anodised aluminium The monitor is protected by a 3 mm double sided antireflective black edged glass DVI I and DVI D inputs Interactive Setup Display allowing the control setup and diagnose of the monitors Monitors provide RS 422 I O allowing the remote control of movements speeds safety settings brightness contrast and backlight The monitors are equipped wi...

Page 9: ...2 USB passthroughs CCUSBPowerD1H USB power CCUSBPowerD1H USB power AHDL DynamicLoop AHDL DynamicLoop AHDSS Min 10 units DynamicShare AHDSS Min 10 units DynamicShare AHHC Min 10 units HDMI fixed AHHC Min 10 units HDMI fixed AHDSPB Priority AHDSPB Priority CABD1H Min 10 units Black anodised CABD1H Min 10 units Black anodised CABD1H Min 10 units Black anodised GFD1H Min 10 units Gold finish GFD1H Min...

Page 10: ...ontain the following items Monitor Power cord Remote control 1 per 5 monitors Power supply 100 2 40Vac 50 60Hz Output 12V User guide Important note This monitor can only work with the power supply included in the shipping box This power supply can not be replaced by any other rather than the original one SYSTEM DESCRIPTION ...

Page 11: ...memory button 2 Press button 2 to raise the display at the memorised position To save the position press and hold button 2 for 3 seconds you will hear a beep sound when the desired position has been saved Please make sure that no objects are located on top of the monitor 3 Closing the monitor button 1 Press button 1 to fold the monitor completely The monitor will fold while holding down this butto...

Page 12: ...vates the OSD menu on screen UP Control up on the OSD menu DOWN Control down on the OSD menu LEFT Control left on the OSD menu RIGHT Control right on the OSD menu OK Selects the function on the OSD menu When the OSD menu is not active on screen selects the input source ...

Page 13: ...of all the functions available for the monitor Press the OK button to confirm When a function is selected press the LEFT and RIGHT buttons in order to change the parameter of the function Press the MENU button to access to the main menu Picture Picture Mode Adjusts the mode of the image Dynamic Standard Mild User Contrast Brightness Colour Sharpness Tint Colour Temperature Adjusts the colour of th...

Page 14: ...m2 Just scan Noise Reduction Adjusts the image noise filter Off Low Medium High Default Screen Only for analogue signals Auto Adjust Horizontal Position Vertical Position Size Phase Backlight Adjusts the backlight screen s level Colour Range Adjusts the colour range 0 255 16 235 ...

Page 15: ...ters to the initial factory parameters Blending OSD window transparency Low Medium High Off OSD Duration Adjusts the time that the OSD menu window remains on the screen Software Update USB Port to use for firmware s upgrade Mirror 0 Image with no flip 1 Vertical flip 2 Horizontal flip 3 Rotate ...

Page 16: ...torical data of the device To start using it WELCOME DISPLAY DATA 1 Bootloader Version The display will show a Bootloader Version message example Bootl Ver 1 01 Bootloader is a program which allows the system to be able to update itself The ISD has a Bootloader and therefore is capable of updating to new versions in order to constantly improve the user experience ...

Page 17: ...ddress which will be accompanied by an acoustic signal BEEP example Address 001 Once the signal has been heard the UP DOWN buttons will allow the user to scroll through all the variety of menus that the device contains To enter into any specific menu simply press the OK button How to modify the values within each menu The values can be selected through the UP DOWN buttons To save the selected valu...

Page 18: ...t be set from 1 to 60 2 VIDEO INPUT SELECTION The device provides the following inputs DVI1 DVI I DVI A and DVI1 D DVI2 DVI D DVI 2D This menu allows the selection of 1 of these 3 inputs 3 MONITOR BRIGHTNESS Brightness level 0 100 4 MONITOR CONTRAST Contrast level 0 100 ...

Page 19: ...position of the device 7 SENSORS INFORMATION It is a diagnostic option that informs about the internal state of the sensors 8 AHnet INFORMATION This menu is useful for programing and diagnose It provides information about the AHnet command that has been received by the device Example AHnet 0 FA 1 01 2 01 3 01 4 00 ...

Page 20: ...0 UNIT STOPS It is a diagnostic option that provides historical data It is very useful to analyze how the device has been used during its lifecycle It provides information about the number of times that the device has been protected and made emergency stops 11 SERIAL NUMBER Provides the device s serial number The serial number can also be obtained via AHnet and AHlink 12 MONITOR DOWN Only use this...

Page 21: ...ed and protection thresholds 14 AHLink Activates AHlink FIRMWARE UPDATE To update the FW version To start the update connect a PC with the APP AH_FW Device Setting Tool to the device through the USB port Proceed with the following steps Unplug the PSU Wait for 1 minute Press and hold the OK button Plug in the PSU A message will appear on the LCD screen when the connection is ready Start updating t...

Page 22: ...e GP2 3 12Vdc 4 Ground to move the monitor to the memorised position pulse signal Use GPI3 6 12Vdc 5 Ground to close the monitor pulse signal Termination Activate ON the termination Only on the last unit of the RS422 bus AHnet RJ45 CAT6 connector for addressable RS422 control There is a loop through connector to use as signal RS422 output Up to 30 monitors can be connected on the same RS422 bus US...

Page 23: ...n ARGB analogue input signal and select DVI A on the OSD monitor menu DVI 2 DVI D input signal Connect a DVI digital input signal and select DVI 2 on the OSD monitor menu Use high quality DVI cables with 2m maximum length On RS422 connectors connect only RS422 signals Be careful c not to connect Network cables or PoE signals It will seriously j damage the monitor ...

Page 24: ...ata RX 4 NC 5 NC 6 Data RX 7 NC 8 NC Connection PINS 1 2 The units respond PINS 3 6 The units receive instructions Protocol to control the monitor by addressable RS422 bus You can connect up to 30 monitors on the same RS422 bus You can use an AH ERT interface to control the RS422 bus The units should have a set address and the address must start by 1 Maximum cable length between ends 500 m 1640 ft...

Page 25: ...A XX 02 01 00 SCREEN ON FB XX 02 01 00 FA XX 02 00 00 SCREEN OFF FB XX 02 00 00 FA XX 03 01 00 DVI A SELECTION FB XX 03 01 00 FA XX 03 00 00 DVI 1 SELECTION FB XX 03 00 00 FA XX 03 03 00 DVI 2 SELECTION FB XX 03 03 00 FA XX 04 01 00 BUTTON LOCK FB XX 04 01 00 FA XX 04 00 00 BUTTON UNLOCK FB XX 04 00 00 FA XX 14 00 00 INQUIRY CONTROL BYTE FB XX 14 CB1 CB2 XX Number of the monitor address Up to 30 m...

Page 26: ...MONITOR HORIZONTAL POSITION 1 1 0 1 MONITOR VERTICAL POSITION 0 1 0 1 MONITOR MEMORISED POSITION 1 0 0 1 SCREEN ON 1 SCREEN OFF 0 DVI A 0 0 DVI 1 0 1 DVI 2 1 1 PROTECTION STOP 1 MONITOR OK 0 CB2 BITE 7 6 5 4 3 2 1 0 BUTTON LOCK 1 BUTTON UNLOCK 0 ...

Page 27: ...or address Up to 30 monitors for each RS422 BUS ZZ Level of the function selected 00 99 Dec COMMAND DESCRIPTION RESPONSE FA XX 15 01 ZZ SET BACKLIGHT LEVEL FB XX 15 01 ZZ FA XX 16 01 ZZ SET CONTRAST LEVEL FB XX 16 01 ZZ FA XX 17 01 ZZ SET BRIGHTNESS LEVEL FB XX 17 01 ZZ XX Number of the monitor address Up to 30 monitors for each RS422 BUS ZZ Level of the function selected 00 99 Dec To send an orde...

Page 28: ... 000 Progressive 1024x768 60Hz 48 363 60 005 Progressive 1024x768 70Hz 56 476 70 070 Progressive 1024x768 75Hz 60 023 75 030 Progressive 1280x720 60Hz 44 772 59 855 Progressive 1360x768 60Hz 47 720 59 799 Progressive 1280x1024 60Hz 63 981 60 020 Progressive 1600x1200 60Hz 75 000 60 000 Progressive 1680x1050 60Hz 64 742 59 946 Progressive 1920x1080 60Hz 66 647 59 980 Progressive ...

Page 29: ... the AHlink option appears Press the OK button to activate the AHlink signal on the unit When the AHlink signal is activated the sound of 5 beeps will indicate that the AHlink signal is active on the unit The wireless AHlink signal automatically desactivates when there is no monitor connected during more than 2 minutes When the AHlink desactivates you will hear a long Beep sound To control and set...

Page 30: ...might no longer be active The AHlink name always begins with the characters AH followed by the four last MAC AHLink address You must select the AH monitor After selecting the AH monitor the first page will upload on your screen This page is used for the basic installation setup ...

Page 31: ... Brightness adjustments SAVE VALUES Memorises the backlight contrast and brightness values AHLINK OFF Turns off the AHlink signal COMMAND Information of the last AHnet command received from RS422 port SENSORS Indicates sensor status S1 SCREEN SENSOR HORIZONTAL POSITION S2 SCREEN SENSOR TOO OPEN S3 FRONT PROTECTION COVER SENSOR ACTIVATED AHNET ADDRESS AH address settings POSITION Screen position PA...

Page 32: ...ll help save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling Please contact your local authority for further details of your nearest designated collection point Penalties may be applicable for incorrect disposal of this waste in accordance with national legislation For business users in ...

Page 33: ...al Display Solutions covers the labour costs to replace any detective parts during the validity of this warranty 4 Transport costs 4 1 In the case that a manufacturing defect occurs within 90 days after the purchase date both freight and insurance costs will be paid by Albiral Display Solutions Although Albiral Display Solutions S L pays for freight and insurance costs Albiral Displays Solutions w...

Page 34: ... and if the product has been manipulated or warranty seals are removed or manipulated 8 The beneficiary of the warranty will hove to send the monitors with the original packaging to warranty there are no damages during the transport 9 The warranty is not valid if the beneficiary of the warranty does not include RMA form and copy of the purchasing invoice Please note that laws vary from country to ...

Page 35: ...Sant Hipòlit de Voltregà 08512 Barcelona Spain tel 34 93 850 23 76 23 83 fax 34 93 850 25 50 23 72 web www arthurholm com e mail marketing arthurholm com This manual can be modified without previous notice ENG Nov 2020 P27178ITEP P27178RUPC P27178USPC P27284DEEP P27284EPPC P27284ESEP P27284GBEP P27284RUPC P27284USPC P27715ESEP P28089DEEP P28089ESEP P28089ITEP P28089USPC P28090EP00 P31160ESES P3116...