ArtFox SKY BEAM 9R User Manual Download Page 12

 

 

 

Page 12 

105-109 

C COLOR11  

110-114 

COLOR11 

115-119 

C COLOR12  

120-124 

COLOR12 

125-129 

C COLOR13  

130-134 

COLOR13 

135-139 

C COLOR14  

140-199 

Rotate forward (fast to slow) 

200-255 

Rotate reverse (slow to fast) 

CH10 

GOBO 

0-4 

White 

5-9 

GOBO1 

10-14 

GOBO2 

15-19 

GOBO3 

20-24 

GOBO4 

25-29 

GOBO5 

30-34 

GOBO6 

35-39 

GOBO7 

40-44 

GOBO8 

45-49 

GOBO9 

50-54 

GOBO10 

55-59 

GOBO11 

60-64 

GOBO12 

65-69 

GOBO13 

70-125 

Rotate forward (fast to slow) 

126-130 

Stop 

131-190 

Rotate reverse (slow to fast) 

191-195 

Shake slow to fast GOBO1 

196-200 

Shake slow to fast GOBO2 

201-205 

Shake slow to fast GOBO3 

206-210 

Shake slow to fast GOBO4 

211-215 

Shake slow to fast GOBO5 

216-220 

Shake slow to fast GOBO6 

221-225 

Shake slow to fast GOBO7 

226-230 

Shake slow to fast GOBO8 

231-235 

Shake slow to fast GOBO9 

236-240 

Shake slow to fast GOBO10 

241-245 

Shake slow to fast GOBO11 

246-250 

Shake slow to fast GOBO12 

251-255 

Shake slow to fast GOBO13 

CH11 

Rainbow 

0-127 

None 

128-255 

Rainbow Open 

CH12 

Prism 

0-30 

None 

31-50 

Prism1 

Summary of Contents for SKY BEAM 9R

Page 1: ...1 SKY BEAM 9R USER MANUAL Please read over this manual before operation the light ...

Page 2: ... Panel operation 6 1 Brief 6 2 Operation 6 1 Operate light with touch or encoder button 6 2 Parameter value setting 6 3 Boolean parameter setting 7 4 Sub Menu Parameter 7 3 Operation and parameter instruction 7 1 Set DMX Address 8 2 Set Light work mode 8 3 Set display 9 4 Test light 9 5 Set light run parameter 10 6 View status 10 Chapter 3 Channel description 11 1 Channel table 11 ...

Page 3: ...e please don t put it in the damp places or even the environment over 60degress Always mount this unit in safe and stable matter Install or dismantle should operate by professional engineer Using lamp the change rate of power voltage should be within 10 If the voltage is too high it will shorten the light s life If it s not enough will influence the effect Please restart it 20 minutes later after ...

Page 4: ...20Ohm minimum 1 4W between terminals 2 and3 IMPORTANT Thewiresmustnotmakecontact witheachotheror withthemetalcasing of theconnectors The casing itself must be connected to the shield braid and to pin 1 of the connectors Figure 1 DMX Cable connection 6 Rigging Optional This equipment can be positioned and fixed by clamp in every direction of the stage Locking system makes it easy to fasten to the b...

Page 5: ... be fixed firmly Take one M12 screw Grade 8 8 or higher to clamp bracket and then screw the nuts Level the two hanging points at the bottom of clamp Insert fastener to the bottom lock the two levers by 1 4 rotating clockwise then install another clamp Install on safety string which stands at least ten times weight as equipment Terminal of the accessory is designed for clamps Make sure pan tilt loc...

Page 6: ...h button As auxiliary input interface if disable touch function the encoder can been choose to set or view the item and then press the encoder button to confirm the selection rotary encoder again set the parameter value finally Press encoder button one again to save value or setting 2 Parameter value setting When the selected item is value need to been modified the dialog shown in Figure 4 will po...

Page 7: ... includes class of parameter and status ADDRESS Set light DMX address WORKMOD Set light work mode master or slave mode when in auto run mode DISPLAY Set display parameter eg select language TEST Used for test light modify DMX channel data to test function the corresponding function of reference channel function table ADVANCE Set light running parameter STATUS view light current status Figure 6 Par...

Page 8: ...de DMX MODE AUTO RUN and SOUND MODE Parameter definition as following DMX Mode Under this mode the light receive data from the DMX controller and move AUTO RUN Under this mode light will run with inside code data ignore data from DMX controller SOUND Ctrl Under this mode light ignore data from DMX controller When there is a strong sound in stage the light will run a scene otherwise it will keep th...

Page 9: ...F keep light up displayer and show main menu Screen Rotation rotate displayer Touch enable Disable or enable touch function when disable use encoder to operate light and set parameter Touch adjust adjust touch function normally not enter this item Figure9 page of display 4 Test light Enter the page as shown in Figure 10 Light will into test mode in this mode the light does not receive the data for...

Page 10: ...se steps light will rectify auto Pan Offset Set PAN original position Tilt Offset Set TILT original position Lamp up when Select lamp on mode includes 3 mode power on after reset done and manual Factory setting restore all parameter to factory setting Figure 11 page of run parameter 6 View status Enter the page as shown in Figure 12 View light current status version DMXClr Click to clear all DMX d...

Page 11: ...o fast strobe 104 107 White 108 207 Slow strobe to fast strobe mode 2 208 212 White 213 251 Free strobe 252 255 White CH8 Frost 0 127 None 128 255 Insert frost CH9 COLOR 0 4 White 5 9 White COLOR1 10 14 COLOR1 15 19 COLOR1 COLOR2 20 24 COLOR2 25 29 COLOR2 COLOR3 30 34 COLOR3 35 39 COLOR3 COLOR4 40 44 COLOR4 45 49 COLOR4 COLOR5 50 54 COLOR5 55 59 COLOR5 COLOR6 60 64 COLOR6 65 69 COLOR6 COLOR7 70 74...

Page 12: ...O13 70 125 Rotate forward fast to slow 126 130 Stop 131 190 Rotate reverse slow to fast 191 195 Shake slow to fast GOBO1 196 200 Shake slow to fast GOBO2 201 205 Shake slow to fast GOBO3 206 210 Shake slow to fast GOBO4 211 215 Shake slow to fast GOBO5 216 220 Shake slow to fast GOBO6 221 225 Shake slow to fast GOBO7 226 230 Shake slow to fast GOBO8 231 235 Shake slow to fast GOBO9 236 240 Shake s...

Page 13: ...slow to fast CH14 Prism2 Rot 0 127 0 400 degrees 128 187 Rotate forward fast to slow 188 195 Stop 196 255 Rotate reverse slow to fast CH15 Macro 0 30 None 31 50 Macro1 51 70 Macro2 71 90 Macro3 91 110 Macro4 111 130 Macro5 130 150 Macro6 151 170 Macro7 171 190 Macro8 191 210 Macro9 211 230 Macro10 231 255 Macro11 CH16 Focus 0 255 From far to near CH17 Lamp 100 105 Close lamp over 3 sencods 200 205...

Page 14: ...14 ...

Page 15: ...15 ...

Page 16: ...16 ...

Reviews: