3.4 Replacing rotating gobos
DANGER!
Replace gobos with the device switched off only.
Unplug from mains before!
1. Disconnect the fixture from mains and allow it to cool.
2. Remove the bottom plastic cover of the head by loosening the 4 quarter-turn fasteners on the cover.
3. Gently pull up the gobo holder from the rotation gobo wheel.
4. Carefully remove the gobo and the spring gobo-lock from the gobo holder by pushing to the gobe from the side
without toothed wheelt. Do not touch the surface of the pattern of the glass gobo - use a suitable glove.
Be careful! Glass!
5. Insert the new gobo (glazy side towards the lamp). Insert the spring-gobo lock
to secure it in the gobo holder.
6. Insert the gobo holder back into rotating gobo wheel.
7. Replace the bottom cover before applying power.