background image

2A 

 

1. 

Safety Introductions 

 

 

WARNING 

 

Please keep this User Manual for future consultation. If you sell the fixture to another 

user, be sure that they also receive this instruction booklet. 

The equipment is in good condition when leaving the factory. Please operate according to 

the user's manual. 

 

Unpack and check carefully there is no transportation damage before using the fixture. 

 

This lamp is only suitable for indoor dry place use. 

 

Installation and operation of lamps should be carried out by professionals. 

 

The unit must be installed in a location with adequate ventilation, at least 50cm from 
adjacent surfaces. Be sure that no ventilation slots are blocked to avoid overheating when 
the lamp is running. 

 

Make sure the power supply voltage is in line with the required power supply voltage 
before operation. 

 

It’s important to ground the yellow/green conductor to earth in order to avoid electric shock. 

 

Maximum ambient temperature is Ta : 40

. Don’t operate it where the temperature is 

higher than this 

 

Do not connect the device to any dimmer pack. 

 

A small amount of smoke or odor may appear when the new lamp is working and will 
disappear after 15 minutes. 

 

Do not put combustible goods beside the device when it is running, in case of fire risk. 

 

Please carefully check whether the power cable is damaged before opening the lamp. If 
there is any damage, please replace it immediately. 

 

Unit surface temperature may reach up to 85

. Don’t touch the housing bare-hand during 

its operation. Turn off the power and allow about 15 minutes for the unit to cool down 
before replacing or serving. 

 

 

Avoid flammable liquid, water or metal to enter the interior of the device, to avoid electric 
shock or fire. If any foreign body enters the lamp, please cut off the power immediately. 

 

Avoid operating in dirty and dusty environment, and clean and maintain lamps regularly. 

 

Do not touch any wire during operation and there might be a hazard of electric shock. 

 

Avoid winding the power cable to other wires. 

Please read the instructions carefully which includes important 
information about the installation, operation and maintenance. 

Summary of Contents for Pixel Blinder Bar

Page 1: ...Pixel Blinder Bar User Manual Please read the instructions carefully ...

Page 2: ...tions 3 3 Accessories 4 4 Installation 4 5 How to set the unit 5 5 1 Control Panel 5 5 2 Main Functions 6 6 How to control the unit 6 6 1 Master Slave Built in Functions 7 6 2 DMX Controller 8 6 3 ArtNet 9 6 4 DMX Channel 9 7 Trouble shooting 10 8 Fixture Cleaning 10 ...

Page 3: ...rate it where the temperature is higher than this Do not connect the device to any dimmer pack A small amount of smoke or odor may appear when the new lamp is working and will disappear after 15 minutes Do not put combustible goods beside the device when it is running in case of fire risk Please carefully check whether the power cable is damaged before opening the lamp If there is any damage pleas...

Page 4: ...not in use or maintained for a long time Please use the original packing material when it needs to be transported again To prevent or reduce the risk of electrical shock or fire do not expose the fixture to rain or moisture Do not look directly at the LED light beam while the fixture is on Due to the magnifying type lens please keep the lens out of contact with direct sunlight Direct sunlight can ...

Page 5: ...sories Standard Accessories 1 1 5m POWERCON Power Cable x 1pc 2 1 5m CAT5eEthernet cable x 1pc Selectable Accessories 1 1 5m POWERCON Power Connection Cable 4 Installation Assemble the units as the below picture ...

Page 6: ...er input connect the power supply 5 Power output connected to the next unit 6 Insurance tube T3 15Amp Protect lamp from damage caused by excessive current or short circuit 7 3 Pin DMX Input Connect the fixture and the controller with 3 Pin XLR DMX Cable and input the DMX signal 8 3 Pin DMX Output Connect the next unit with 3 Pin XLR DMX Cable and outoput the DMX signal 9 NUTR RJ45 Input Output Con...

Page 7: ...TER button and the display will blink Use DOWN and UP button to change the mode Once the required mode has been selected press ENTER button to setup or it will automatically return to the main functions without any change after idling 1 minute Back to the functions without any change press MENU button The main functions are shown below ...

Page 8: ...p to when the Channel Mode is shown on the display Pressing the ENTER button Use the DOWN and UP button to select the 7CH 28CH 32CH 384CH press the ENTER button to setup M S Mode Select M S Mode and press ENTER to confirm Use UP DOWN button to select automatic or manual mode and press ENTER button to save Press MENU button to return to the previous MENU or wait for 1 minute to exit MENU mode autom...

Page 9: ...r to control the units you have to set DMX address from 1 to 512 channel so that the units can receive DMX signal Press the MENU button up to when the DMX Address is showing on the display Pressing ENTER button and the display will blink Use DOWN and UP button to change the DMX512 address Once the address has been selected press and keep ENTER button pressed up to when the display stops blinking o...

Page 10: ...to control lamps through ArtNet you must first select the 384 channel mode in the menu Then confirm that the Eth Net address is consistent with the multimedia server If MAC addresses conflict use random addresses 6 4 DMX Channel Channel Mode ...

Page 11: ...9A ...

Page 12: ...9B ...

Page 13: ...ms check the pins on connectors or on PCB of the fixture or the previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit Some fixtures don t respond to the easy controller 1 You may have a break in the DMX cabling 2 Check the LED for the response of the master slave mod...

Page 14: ...e environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days ...

Reviews: