background image

 

14

 

 

 

 

3

 

The unit is for indoor use only. Use only in a dry location. 

 

The   unit   must   be   installed   in   a   location   with   adequate   ventilation,   at   

least   50cm   from adjacent surfaces. Be sure that no ventilation slots are 

blocked. 

 

Disconnect main power before replacement or servicing. 

 

 

Make sure there are no flammable materials close to the unit while operating as 

it is fire hazard. 

 

Use safety cable when fixes this unit. DO NOT handle the unit by taking its head 

only, but always by taking its base. 

 

 

Maximum ambient temperature is Ta: 40

. DO NOT operate it where the 

temperature is higher than this Unit surface temperature may reach up to 85

DO NOT touch the housing bare-hand during  its  operation.  Turn  off  the  power 

and allow about 15 minutes for the unit to cool down before replacing or serving. 

 

 

In  the  event  of  serious  operating  problem,  stop  using  the  unit 

immediately.Never  try  to  repair  the  unit  by  yourself.  Repairs  carried  out  by 

unskilled  people  can  lead  to  damage  or  malfunction.  Please  contact  the 

nearest  authorized  technical  assistance  center.  Always  use  the  same  type 

spare parts. 

 

 

DO NOT touch any wire during operation as high voltage might be causing 

electric shock. 

 

Warning: 

 

 

To prevent or reduce the risk of electrical shock or fire, do not expose the unit to 

rain or moisture. 

 

DO NOT open the unit within five minutes after switching off. 

 

 

The    housing,    the    lenses,    or    the    ultraviolet    filter    must    be    replaced   

if    they    are    visibly damaged. 

Summary of Contents for LED Beam Wash 19E

Page 1: ...e fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days ArtFox Lighting LED Beam Wash 19E User manual Please read the instructions carefully bef...

Page 2: ...ctor to earth in order to avoid electric shock 15 5 Trouble shooting Following are a few common problems that may occur during operation Here are some suggestions for easy troubleshooting A The unit does not work no light and the fan does not work 1 Check the connection of power and main fuse 2 Measure the mains voltage on the main connector 3 Check the power on LED B Not responding to DMX control...

Page 3: ...ach up to 85 DO NOT touch the housing bare hand during its operation Turn off the power and allow about 15 minutes for the unit to cool down before replacing or serving In the event of serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized tech...

Page 4: ... use a safety cable that can hold 12 times of the weight of the unit when installing the fixture The equipment must be fixed by professionals And it must be fixed at a place where is out of the touch of people and has no one pass by or under it 2 Technical Specifications Light Sources 19 x 15W 4in1 OSRAM RGBW LED Beam Angle 7 60 Power Consumption 300W Power Voltage AC 100 240V 50 60Hz Dimension 33...

Page 5: ...ram 6 secne41 48 of EEPROM 220 239 Internal program 7 secne49 56 of EEPROM 240 255 Music Control secne of Program 1 Note Color Chase Patterns scene G B W and Color Presets four channels is determined by the channel in front of R to note that if these channels are not selected 5 Construction Display LCD Display Data In Out socket 3 pin 5 pin XLR sockets Power Socket Powercon in out Protection Ratin...

Page 6: ...to enter into 2 Show Set DMX Address DMX Address 001 Press the UP and DOWN keys to amended 3 Press ENTER keys to save and Exit Press the MENU Keys does not save and Exit 11 75 79 Salmon 80 84 Turquoise 85 89 Light Green 90 94 Steel Blue 95 99 Orange 100 104 Straw 105 109 Pale Lavander 110 114 Pink 115 119 RED WHITE 120 124 GREEN RED 125 129 BLUE RED 130 134 WHITE RED 135 139 WHITE PINK 140 144 WHI...

Page 7: ...001 XXX PAN Slave Master Auto Alone Auto Master Music Alone Music Change address Show each channel value Slave receive position select auto run mode Sound auto run inform Temp Inf Head Temperature XXX current tempreture Soft Inf V1 0 software version Person Status settings Pan Reverse Tilt Rev P Degree Feedback Movement Speed Mic Sensitivity ON OFF ON OFF 540 360 ON OFF Speed 1 2 0 99 Pan scan opp...

Page 8: ...l arrays 0 255 Red 0 Black 255 100 Red 9 11 Green LED all arrays 0 255 Green 0 Black 255 100 Green 12 Blue LED all arrays 0 255 Blue 0 Black 255 100 Blue 13 White LED all arrays 0 255 White 0 Black 255 100 White 10 Red LED array 1 0 255 Red 0 Black 255 100 Red 11 Green LED array 1 0 255 Green 0 Black 255 100 Green 12 Blue LED array 1 0 255 Blue 0 Black 255 100 Blue 13 White LED array 1 0 255 White...