24

LED

Function

Color

Description

OK

ILC274D
Module 
Status

OFF

If power is applied to the system, an internal fault with the ILC274D may exist

n

 

Green

Normal operation

n

 

Yellow

If no other status LEDs indicate a minor alarm, then a temperature alarm is indicated

n

 

Red

If no other status LEDs indicate a major alarm, then an internal error is indicated, such as an 
onboard communications error or an onboard power error

EMS

IL Manager  
System 
Status

OFF

The ILC274D module is in local mode and its configuration is controlled by the onboard 
configuration switches

n

 

Green

The ILC274D module is in remote mode and the configuration has been set by the EMS.  When in 
remote mode, the actual configuration of the module will likely not match the settings of the 
configuration switches and changing the configuration switches will have no effect on the 
module operation

TX

Transmitter
Status

OFF

Transmitter is disabled

n

 

Green

Normal operation (repeating input signal)

n

 

Red

SFP TX failure exists

 

Red

No SFP is installed

RX

Receiver 
Status

n

 

Green

Normal operation

n

 

Yellow

Link errors detected

 

Yellow

Receive optical power is high

n

 

Red

No input signal or the input signal type is incorrect (not a valid ILC274M or  
ILC274M signal)

 

Red

Possible causes:  
• A low receiver power condition exists
• No SFP is installed
• An SFP RX failure exists

A, B, C, D

270 Mb/s  
Channel 
Status

OFF

Channel is disabled on the ILC274D or ILC274M

n

 

Green

270 Mb/s video detected

n

 

Yellow

No signal to the ILC274M

n

 

Red

Video input signal rate is outside the range (270 Mb +/- 100 ppm)

 

Flashing yellow

 | 

 

Flashing red

Install SFP

DLC274D FRONT PANEL LEDS