background image

Fiberlink®

3394 Series

Bi-directional 3G/HD/SD-SDI Transmission  with two way 

audio, data, 10/100 Ethernet & contact closure 

over one or two fibers.

Artel Video Systems’ Fiberlink® 3394

User’s Manual

This manual covers the 

following products:

3394-x3z
3394-x7z
3395-x3z
3395-x7z
3396-x3z
3396-x7z 
3397-x3z
3397-x7z

Box

 

or 

Car

d

World Headquarters

5B Lyberty Way

Westford MA 01886  USA

Tel:   (978) 263-5775

Fax:  (978) 263-9755
[email protected]

artel.com

Summary of Contents for Fiberlink 3394 Series

Page 1: ...re over one or two fibers Artel Video Systems Fiberlink 3394 User s Manual This manual covers the following products 3394 x3z 3394 x7z 3395 x3z 3395 x7z 3396 x3z 3396 x7z 3397 x3z 3397 x7z Box or Card...

Page 2: ...o Output Switch Settings For Box Versions 11 Data Configuration For Box Versions 11 Ethernet Configurations For Box Versions 12 Baud Rate Configuration For Box Versions 12 Data Wiring For Box Versions...

Page 3: ...o two each way Transmit 1 channel of bi directional RS Type data Transmit 10 100 Base T Ethernet Transmit 1 channel of bi directional contact closure All channels are independent and available simulta...

Page 4: ...rs The part number will indicate each by replacing z with L or S Data Specifications General Specifications Model Part Number Specification Technical Specifications Data Channels 1 Channel Bi Directio...

Page 5: ...s Frequency Response 0 0 5 dB 20 Hz 20 kHz Maximum Audio Level 10 dBu Signal to Noise Ratio A weighted 95 dB referenced full scale balanced THD 0 002 20Hz 20 kHz full scale Channel Phase Differential...

Page 6: ...pecifications Number of Inputs 1 Data Bandwidth 19 4 Mbps to 2 97 Gbps Supported Standards SMPTE 259M 292 424M 2006 305M 344M DVB ASI Reclocked Data Rates 270 Mbps SMPTE 259M DVB ASI 270 1 485 Gbps SM...

Page 7: ...per SMPTE 292 0 4 ns to 1 5 ns at 270 Mbps per SMPTE 259M Overshoot 10 of amplitude Timing Jitter 0 2 UI at 270 Mbps 1 0 UI at 1 485 Gbps 2 0 UI at 2 97 Gbps with color bar signal Alignment Jitter 0...

Page 8: ...n Fiberlink devices Operating loss budget must not be exceeded Operating Loss Budget Maximum Useable Distance The Fiberlink 3394 Series of fiber optic transmission systems are ready for immediate use...

Page 9: ...d Alarm Circuitry section of this manual 11 The system should now be operational Note The Rack Card version has an additional red LED for indicating the presence of an alarm condition loss of signal R...

Page 10: ...ut Channel 2 Input 1 2 1 2 G Ground Shield Channel 1 Input Channel 2 Input Balanced Channel 1 Signal Channel 2 Signal Shield Channel 1 Ground Channel 2 Ground Un Balanced Channel 1 Output Channel 2 Ou...

Page 11: ...Channel Balanced Unbalanced Channel 1 controlled by Switch 2 Channel 2 controlled by Switch 1 Audio Output Switch Settings For Box Versions Data Configuration For Box Versions The Fiberlink 3394 Seri...

Page 12: ...5 6 7 8 9 19 2k E 1 2 3 4 5 6 7 8 9 38 4k E 1 2 3 4 5 6 7 8 9 57 6k E 1 2 3 4 5 6 7 8 9 76 8k E 1 2 3 4 5 6 7 8 9 4800 E 1 2 3 4 5 6 7 8 9 9600 Ethernet Configurations For Box Versions DATA CONFIG E...

Page 13: ...9 RS 422 485 4 Wire RS 485 2 Wire RS 232 Data Wiring For Box Versions RS 485 2 Wire RS 232 G 1 2 3 4 Input G 1 2 3 4 Output RS 422 485 4 Wire G 1 2 3 4 Input G 1 2 3 4 Output G 1 2 3 4 Input Output Co...

Page 14: ...nnel Balanced Balanced Unbalanced 600 Ohms 24k Ohms 24k Ohms 1 2 3 4 Channel 1 controlled by Switches 1 2 1 2 3 4 1 2 3 4 1 2 3 4 Channel 2 controlled by Switches 3 4 Audio Input Switch Settings For C...

Page 15: ...h Settings For Card Version The Fiberlink 3394 Series card units have three switch blocks one 10 position one 4 posi tion and one 2 position The first block Data Config represents the Ethernet and RS...

Page 16: ...2 485 4 Wire 1 2 3 4 5 6 7 8 9 10 RS 485 2 Wire 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 RS 232 2400 1 2 3 4 5 6 7 8 9 10 DATA CONFIG 4800 1 2 3 4 5 6 7 8 9 10 DATA CONFIG 9600 1 2 3 4 5 6 7 8 9 10 D...

Page 17: ...RS 485 2 Wire Contact Closure Wiring For Card Versions Ethernet Configurations For Card Version 10 Base T Ethernet 100 Base T Ethernet G 1 2 3 4 G 1 2 3 4 RS 232 Input Output G 1 2 3 4 G 1 2 3 4 RS 42...

Page 18: ...n output to drive a model 6020A Alarm Sensing Module which provides an audible tone and activates a set of contacts for external signaling purposes Alarm Switch Settings Options Alarm Switch Settings...

Page 19: ...l On Indicates HD 3G SDI data rate lock at 1 485 Gbps or 2 97 Gbps SD TX Off Indicates no SD SDI data rate lock electrical On Indicates SD SDI data rate lock at 270 Mbps SD RX Off Indicates no SD SDI...

Page 20: ...ould provide the first clue as to the origin of any operational failure If these are off it usually means that the fiber is broken or has too much attenuation Next be certain that the input and output...

Page 21: ...transmission and that electrical connections are secure and accurate Please see the Troubleshooting section of this manual for additional information An optical power meter such as the Fiberlink 6650...

Page 22: ...be limited at its option to either the repair or replacement of defective units including free materials and labor In no event shall Artel be responsible for any incidental or consequential damages o...

Page 23: ...r convenient on site testing of fiber networks during construction and maintenance procedures Fiberlink 6650 Optical Power Meter The Fiberlink 6650 Optical Power Meter is a high accuracy high resoluti...

Page 24: ...This manual covers the following products 3394 x3z 3394 x7z 3395 x3z 3395 x7z 3396 x3z 3396 x7z 3397 x3z 3397 x7z Box or Card World Headquarters 5B Lyberty Way Westford MA 01886 USA Tel 978 263 5775 F...

Reviews: