Page 19
Fiberlink® 3394 Series User’s Manual
Fiberlink® 3394 Series
The Fiberlink® 3394 Series has several indicator LEDs that are used to monitor the state of
the unit. Card versions have an additional Alarm LED.
Indicator LEDs
Transceiver LED
LED Status Definition
Power
On
Indicates that correct power has been applied.
HD/3G TX
Off
Indicates no HD/3G-SDI data rate lock (electrical)
On
Indicates HD/3G-SDI data rate lock at 1.485 Gbps
or 2.97 Gbps
HD/3G RX
Off
Indicates no HD/3G-SDI data rate lock (optical)
On
Indicates HD/3G-SDI data rate lock at 1.485 Gbps
or 2.97 Gbps
SD TX
Off
Indicates no SD-SDI data rate lock (electrical)
On
Indicates SD-SDI data rate lock at 270 Mbps
SD RX
Off
Indicates no SD-SDI data rate lock (optical)
On
Indicates SD-SDI data rate lock at 270 Mbps
Audio In
Off
No audio input present (electrical)
Blink
Audio input detected (electrical)
Audio Out
Off
No audio output present (optical)
Blink
Audio output active (optical)
Data
Off
Indicates no data present (electrical or optical)
Blink
Indicates data present (electrical or optical)
Alarm
On
Alarm Condition.
(See Alarm Settings section, page 18)
Note: The 3G, HD and SD LEDs indicators are off when a non-standard signal is applied.