NSTALLATION MANUAL
&
USER GUIDE
7
6.
Fireplace with fan system (up to 120m
2
)
Fig. 11: Fireplace with Fan
•
A
Open a Ø15cm hole in the cladding of the fireplace, for the circuit of the fan and cover it
with an adjustable grille.
•
B
Open a Ø15cm hole (as it is placed in A) or open it in the internal wall of the next room,
except the kitchen, bedroom, bathroom (Fig. 11), for circuit of fan and cover it with a grille, too.
•
C
Open a Ø10cm hole in the external wall (Fig. 11) to lead the air into the combustion chamber
and cover it with an external grille.
For example, the following scheme (Fig. 12)
describes the main hot air distributor which
heats more than one room. The maximum
length of the air distributor is 12m, when there
are double conduits into the cross section
(made by smooth galvanized sheet-metal).
Also smooth metallic pipe should be used for the
rest of 12m on a single conduit (Fig. 12) or 6+6m
on a dual conduit (Fig.13).
Fig. 12: Fireplace with fan (120m
2
)
Fig. 13
C
A
B
Dual conduit