background image

8

OPENING AND CLOSING BY USER

The Opening and Closing by user code identifies the user who disarms (opening) and

arms (closing) the system.  This is accomplished by assigning an individual access code

to each user, (up to 8 users on the AV9000 and SC700 ).  The primary access code is

always reported as user one.  Seven additional secondary access codes may be selected

for the AV9000 and SC700.

Select secondary codes as shown in “Entering or Changing Secondary Access Code”

Section.

CHIME MODE

Your installer may have designated certain burglary zones to briefly activate the mini-

sounder contained in each keypad.  These zones typically annunciate that a door has

been opened or closed while the panel was disarmed.  To select for chime operation,

enter the following key sequence:

Figure 10

*

#

3

1

2

4

ACCESS CODE

6

If chime operation is not desired, simply re-enter the key sequence.

FAULT CONDITION

A Fault Condition could, if unheeded, potentially render your system inactive.  If such a

fault should occur it will be indicated by a flashing green “READY” light, a TROUBLE

message on the LCD display, and an audible warning tone at the keypad.

To identify the nature of the Fault Condition, enter the following sequence.  This will also

silence the audible warning:

Figure 13

9

*

#

3

1

2

4

ACCESS CODE

Fault conditions will be displayed on the LCD display.

The LCD display  will now indicate the nature of the problem and it will scroll through the

problems if there is more than one.   Discuss with your installer what action to take if a

problem should occur.  If a trouble condition occurs on a fire zone,(or Day/Night Trouble

Summary of Contents for EKP1L

Page 1: ...1 EKP1L LCD KEYPAD Owner s Manual use with AV9000 series Control panels IT IS IMPORTANT FOR YOUR SAFETY TO TEST YOUR SYSTEM AND IT S COMPONENTS REGULARLY P N 64812818 A PDF 10 14 97...

Page 2: ...y contain information which pertains to your system The material in this publication is for information purposes only and is subject to change without notice SENTROL INC assumes no responsibility for...

Page 3: ...nnunciation Your keypad has the added convenience of additional access codes These secondary codes are designed to provide access to a maid or other service persons for whom you want to grant entry Ob...

Page 4: ...display and assume Auto Scrolling is enabled These descriptions may be changed by your installer DISARMING AND SILENCING THE SYSTEM when ARMED light is on To Disarm your system assume Access Code 123...

Page 5: ...pen will be scrolling through the display Let us assume that the zone 3 FRONT BEDROOM window is open The zone 3 description FRONT BEDROOM will be in the display Entering the Access Code will not arm t...

Page 6: ...ystem will normally arm in the Delay Mode when leaving the premise This will delay arming allowing time to exit When entering the alarm will be delayed allowing time to disarm the system The audible w...

Page 7: ...It is important for your safety that you test your system regularly TESTING COMMUNICATOR Check with your installer as to how to test and how often to test the communicator portion of your system Vario...

Page 8: ...sarmed To select for chime operation enter the following key sequence Figure 10 3 1 2 4 ACCESS CODE 6 If chime operation is not desired simply re enter the key sequence FAULT CONDITION A Fault Conditi...

Page 9: ...monitoring station Press the 9 key or the 0 key depending on how your system is programmed after your Access Code then press the ENTER The system will disarm and a silent alarm will be transmitted NO...

Page 10: ..._____________ PARTITIONED MODE Your installer dealer may have assigned specific zone s for you Other users are sharing the same alarm system There is very little interaction between users and arming a...

Page 11: ...There are times when you may be instructed by the Monitoring Center to use one of these special commands for that purpose The panel can be instructed to call the computer or to answer when the compute...

Page 12: ...reaches the ground 5 Draw a sketch of the escape route and familiarize everyone in the home with it 6 Select a meeting place outside where everyone is to report 7 Practice the escape plan with everyon...

Page 13: ...products from the retail purchaser s location If examined equipment is found not to be defective or is not for some other reason within the warranty coverage Sentrol Inc s service time expended will...

Page 14: ...510 Tate Boulevard Hickory North Carolina 28601 1 800 800 2626 ING BUT NOT LIMITED TO THE IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED NO OTHER PERSON OR ENT...

Reviews: