5
ARMING SYSTEM WITH READY LIGHT ON OR OFF
If the READY light is on, all zones may be armed by entering your Access Code, using
the key sequence in Figure 3. If the READY light is not on you must either go and close
the door or window that is open or BYPASS the zone and eliminate it from the system for
this ARMING. When the READY light is not on the display will show NOT READY and scroll
through the zone descriptions of the zones that are NOT READY.
Figure 3
✚
▲
#
■
4
●
1
●
3
2
ACCESS CODE
Your system is now armed. The armed light is on and the display shows ARMED
ZONE BYPASS with READY LIGHT ON OR OFF
If the ready light is off the display will show NOT READY and the description of the zone
that is open will be scrolling through the display. Let us assume that the zone 3 "FRONT
BEDROOM" window is open. The zone 3 description "FRONT BEDROOM" will be in the
display. Entering the Access Code will not arm the system because the zone 3 window
is open. Suppose that the window is intentionally left open to allow some air circulation
and the rest of the zones are to be armed. To bypass a zone, enter your access code,
then enter the number of the zone to be bypassed (in this case 3), enter key sequence
as follows:
Figure 4
✚
✚
▲
#
●
3
●
3
■
4
●
1
2
ACCESS CODE
All the other burglary zones except zone 3 will ARM and the display will show ARMED.
Zone 3 is now deactivated. If the window is closed and opened again, an alarm condition
will not result, as this zone will be bypassed until the system is disarmed and rearmed.
When the system is disarmed the bypass is removed.
Additional zones may be bypassed in the same manner.