ARMING SYSTEM WITH READY LIGHT ON OR OFF

If the READY light is on, all zones may be armed by entering your Access Code, using

the key sequence in Figure 3. If the READY light is not on you must either go and close

the door or window that is open or BYPASS the zone and eliminate it from the system for

this ARMING. When the READY light is not on the display will show NOT READY and scroll

through the zone descriptions of the zones that are NOT READY.

Figure 3

#

4

1

3

2

ACCESS CODE

Your system is now armed.  The armed light is on and the display shows ARMED

ZONE BYPASS with READY  LIGHT ON OR OFF

If the ready light is off the display will show NOT READY and the description of the zone

that is open will be scrolling through the display. Let us assume that  the zone 3 "FRONT

BEDROOM"  window is open. The zone 3 description "FRONT BEDROOM"  will be in the

display. Entering the Access Code will not arm the system because the zone 3 window

is open. Suppose that the window is intentionally left open to allow some air circulation

and the rest of the zones are to be armed.  To bypass a zone, enter your access code,

then enter the number of the zone to be bypassed (in this case “3”), enter key sequence

as follows:

Figure 4

#

3

3

4

1

2

ACCESS CODE

All the other burglary zones except zone 3 will ARM and the display will show ARMED.

Zone 3 is now deactivated.   If the window is closed and opened again, an alarm condition

will not result, as this zone will be bypassed until the system is disarmed and rearmed.

When the system is disarmed the bypass is removed.

Additional zones may be bypassed in the same manner.

Summary of Contents for EKP1L

Page 1: ...1 EKP1L LCD KEYPAD Owner s Manual use with AV9000 series Control panels IT IS IMPORTANT FOR YOUR SAFETY TO TEST YOUR SYSTEM AND IT S COMPONENTS REGULARLY P N 64812818 A PDF 10 14 97...

Page 2: ...y contain information which pertains to your system The material in this publication is for information purposes only and is subject to change without notice SENTROL INC assumes no responsibility for...

Page 3: ...nnunciation Your keypad has the added convenience of additional access codes These secondary codes are designed to provide access to a maid or other service persons for whom you want to grant entry Ob...

Page 4: ...display and assume Auto Scrolling is enabled These descriptions may be changed by your installer DISARMING AND SILENCING THE SYSTEM when ARMED light is on To Disarm your system assume Access Code 123...

Page 5: ...pen will be scrolling through the display Let us assume that the zone 3 FRONT BEDROOM window is open The zone 3 description FRONT BEDROOM will be in the display Entering the Access Code will not arm t...

Page 6: ...ystem will normally arm in the Delay Mode when leaving the premise This will delay arming allowing time to exit When entering the alarm will be delayed allowing time to disarm the system The audible w...

Page 7: ...It is important for your safety that you test your system regularly TESTING COMMUNICATOR Check with your installer as to how to test and how often to test the communicator portion of your system Vario...

Page 8: ...sarmed To select for chime operation enter the following key sequence Figure 10 3 1 2 4 ACCESS CODE 6 If chime operation is not desired simply re enter the key sequence FAULT CONDITION A Fault Conditi...

Page 9: ...monitoring station Press the 9 key or the 0 key depending on how your system is programmed after your Access Code then press the ENTER The system will disarm and a silent alarm will be transmitted NO...

Page 10: ..._____________ PARTITIONED MODE Your installer dealer may have assigned specific zone s for you Other users are sharing the same alarm system There is very little interaction between users and arming a...

Page 11: ...There are times when you may be instructed by the Monitoring Center to use one of these special commands for that purpose The panel can be instructed to call the computer or to answer when the compute...

Page 12: ...reaches the ground 5 Draw a sketch of the escape route and familiarize everyone in the home with it 6 Select a meeting place outside where everyone is to report 7 Practice the escape plan with everyon...

Page 13: ...products from the retail purchaser s location If examined equipment is found not to be defective or is not for some other reason within the warranty coverage Sentrol Inc s service time expended will...

Page 14: ...510 Tate Boulevard Hickory North Carolina 28601 1 800 800 2626 ING BUT NOT LIMITED TO THE IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED NO OTHER PERSON OR ENT...

Reviews: