ARROWELD RADIOACTIVITY User Manual Download Page 8

ARW-9501

 - 

User’s manual

 User’s manual

 - 

ARW-9501

12

13

1–  Window to test ray sensor (G.M Geiger counter 

tube)

2– 

γ

β

+

γ

α

+

β

+

γ

 ray measurement two-way(left 

right) rotation selector switch

3–  Reading LCD liquid crystal display with backlight
4–  SETUP function keys, (option date, time, alarm 

value, buzzer sound switch, mean value measure-
ment time, Bluetooth switch)

5–  Data storage record key and parameter setting 

down buttons

6–  Power switch and the back light switch button
7–  SV/h and R/h unit measuring switch button
8–  Enter and confirm button
9–  ESC exit button (in any setting or measuring condi-

tions, press this button can return to Setup state)

10–  Meter battery energy measuring key and parame-

ter setting up key

11–  SV unit accumulation count key and timing mea-

suring key

12–  CPS,CPM, pulse counting measurement unit 

switch button  

1–  Boot nuclear radiation ray measuring dynamic icon instruc-

tion

2–  Real-time date, time and mark symbol indicating
3–  Measuring function set symbol indicating
4–  Measurement reading and unit symbols indicating
5–  Measurement reading article mimic diagram instructions
6–  Measuring ray type icon instruction

Ray types

α

β

γ

, x

Range 
(automatic selection 
range)

Radiation dose rate: 0.01µSv/h - 1000µSv/h      
Pulse dose rate: 0-4000cpm  -  0-4000cps 
Radiation dose accumulation total value: 0.001µSv – 9999Sv 
Pulse dose accumulation total value: 0-9999 

Sensibility

When in environment background of energy is 1 Sv/h Cobalt - 60 ray, it is 108 pulse or 1000 CPM/
mR/hr

α 

- from 4.0  million volt MV   

β 

-  from 0.2   million volt MV

γ 

- from 0.02   million volt MV

X – from 0.02  million volt MV

Basic accuracy

<10%(less than 500µSv/h)
<20%(less than 600µSv/h) 

Ray selection switch

combination selection to 

α

β

γ

, x

Sensor

Halogen fill detector (G.M Geiger counter tube)

Output port

Bluetooth wireless data transmission (Space transmission distance 10m)

Mean time 

Manual or automatic adjustable between 2 to 12 seconds

Show  

Big screen with 4 digit LCD, with bar graph display, following data can be shown: 
Radiation dose rate, pulse dose rate, radiation dose accumulative value, pulse dose accumulative va-
lue, time, date, alarm value, max radiation dose rate, radiation type, measuring dynamic icon, battery 
power indicator, etc..

Warming function

Alarm value can be set freely,  the default Settings is 5 μ Sv/hr

Normal natural envi-
ronment radiation value

Less than 0 - 0.2 uSv / h

Memory function 

Automatic storage 4000 set of data, and record a set of data per minute(including real-time date, 
time, measuring value and measurement unit)

Bluetooth transmission 
data

Every second transmission 1 set of data
(including real-time date, time, measuring value and measurement unit)

Software 

Data real-time far transfer display, analysis and record

Detector working 
temperature

0° ÷ 50°C 

Weight  

206 g

Dimension 

Length 200cm, width 70mm, high 45mm 

Power source  

3.6V High-energy lithium-ion batteries 

Quality certificate 

European CE, US FCC-15 

Note: 

Sievert (mark is Sv, unit, 1Sv=100 rem), rem (roentgen equivalent man)
μSv/h (unit of ray radiation dose rate)
1SV=100Rem
1 rem=1cSv=10mSv
1uR/h=10uSv/h
1mR/h =10mSv/h

CPS: pulse counts per second (In the pulse rate model, pulse has constantly been measured by counter tube  and 
translated into pulse rate)
CPM: pulse counts per minute(In the pulse rate model, pulse has constantly been measured by counter tube and 
translated into pulse rate)

meter PaneL desCriPtion:

LCd disPLay symboL desCriPtion

basiC sPeCifiCations

1

2

3

4

5

6

7

8

9

10

11

12

   

1

2

3

4

5

6

7

12

11

10

9

8

6

5

4

3

2

1

   

1

2

3

4

5

6

   

   

Summary of Contents for RADIOACTIVITY

Page 1: ...zione delle sanzioni amministrative di cui al dlgs n 22 1997 articolo 50 e seguenti del dlgs n 22 1997 USER INFORMATION in accordance with art 13 of the Legislative Decree of 25th July 2005 no 15 Impl...

Page 2: ...d interramenti dove possa esserci rischio di radioattivit nucleare Rilevamento di materia radioattiva nei rivestimenti o nei materiali a casa od in ufficio Radiazione pericolosa di gioielleria ed altr...

Page 3: ...ne combinata x Sensore Rilevatore a riempimento alogeno tubo di conteggio Geiger G M Porta d uscita Trasmissione Bluetooth dei dati senza fili alla distanza di 10 metri Tempo per la media Manuale od a...

Page 4: ...o valore Tasto di misurazione conteggio di dose accumulata 1 Premere il tasto SV per attivare la modalit di conteggio della dose accumulata infinita normale il display indica l icona della dose Sv Poi...

Page 5: ...ne spariscono Messa a punto del Menu Premendo il tasto setup si entra nell interfaccia di messa a punto del menu data ora allarme suono d impulso impostazione tempo medio T trasmissione dati senza fil...

Page 6: ...o automaticamente par tendo dai dati iniziali in modo da far posto ad dati pi recenti 2 Premendo nuovamente il tasto SAVE si esce dalla modalit memorizzazione Trasmissione dati Bluetooth BT 1 Premere...

Page 7: ...where have risk of nuclear radioactive Family and office decorate material radioactive material detection family and office Harmful radiation of personal valuable property and jewelry Medicinal usage...

Page 8: ...ction switch combination selection to x Sensor Halogen fill detector G M Geiger counter tube Output port Bluetooth wireless data transmission Space transmission distance 10m Mean time Manual or automa...

Page 9: ...ccumulative radiation dose within a period of time of the current environment The initial unit is Sv it will automatically switchover the unit to mSv or Sv when the dose reach a certain value Dose acc...

Page 10: ...ther operation mode then measuring results disappear Menu set up Press setup button enters into menu setup interface Date time alarm pulse sound mean time set T Bluetooth wireless data transmission BT...

Page 11: ...resh the beginning data and then record storage circulatory 2 Press SAVE button again will exit data storage mode Bluetooth data transmission BT 1 Press SETUP key once then select Bluetooth BL icon by...

Reviews: