![Arris Touchstone TM508 Installation Manual Download Page 27](http://html1.mh-extra.com/html/arris/touchstone-tm508/touchstone-tm508_installation-manual_2976257027.webp)
17
TM508/TM512 Installation Guide Release 5 Standard 1.2 Mar 2007
5
Tighten the screws to firmly hold the punch-down block against the
mounting surface.
Connecting
Subscriber Wiring
Follow these steps to connect subscriber wiring to the punch-down
block. Consult the following diagram while making connections.
1
Identify the tip-ring wire pair that should be associated with the
Telephony Modem line that you are connecting.
2
Route the wire pair to reach the right side of the punch-down block.
3
Using the punch tool, punch the tip wire into the first of the two
connections for the line, and the ring wire into the second connec-
tion. It is not necessary to strip the wires before punching.
4
Install two bridging clips across the tip and ring lines to enable tele-
phone service (clips for line 1 are shown above).
5
Repeat steps 1 through 4 for each line to install.
6
Close the punch-down block cover after connecting all lines.
Bridging Clips
(required to
enable service)
Network side
Subscriber side
Line 1 – Tip
Line 1 – Ring
Line 1 – Tip
Line 1 – Ring
Summary of Contents for Touchstone TM508