1
GND
2
LTM –>SF
3
SF –> LTM
4
LIGHTMETER
5
GND
6
5V-LTM
7
LIGHT-TIME
8
GND
9
LIGHT-HI
10
LIGHT-LO
11
FLASH-HI
12
FLASH-LO
X2
4
12
10
9
8
7
6
5
1
3
2
11
41
LIGHT socket
Singleframe Handcontrol
7.6 Light Control
7.6.1 Switching on/off Light
The Singleframe Hand Control generates output signals
which enable through the LIGHT socket
➪
photo
luminaires
to be switched on via an external power circuit at a certain
time before exposure and then switched off immediately
after exposure. The signal to activate the light is given by
the Singleframe Hand Control by short-circuiting the
contacts LIGHT-HI and LIGHT-LO
➪
photo
.
How long before exposure the signal for the light is given
can be determined via a resistance between the contacts
LIGHT-TIME and GND
➪
photo
in the cable which is
plugged into the LIGHT socket.
Select the resistance so that all lighting instruments
reach their full brightness and colour temperature.
The internal switch of the Singleframe Hand
Control (LIGHT-HI, LIGHT-LO) may be loaded
with max. 100 mA and 60V).