ARO PD10P-X Operator'S Manual Download Page 7

PD10P-X 

Page 7 of 8

168 

111

  TORQUE REQUIREMENTS

NOTE: DO NOT OVERTIGHTEN FASTENERS.

ALL FASTENERS ARE METRIC.

Torque (105 and 134) screw to 35 - 40 in. lbs (4.0 - 4.5 Nm).

LUBRICATION / SEALANTS

Apply anti-seize compound to threads at assembly.

Apply Lubriplate FML-2 grease to “O" rings, “U" Cups & mating parts.

139 

138 

 134

135

133

174 

121

118

173 

169 

172 

171 

170

167

121

 174

118

166 

132 

141 

140

200 

233

176 

PILOT VALVE

PART GROUP

MAJOR

VALVE

A replacement Major Valve Service Assembly is available separately, which includes the following:

637395-1 for models PD10P-X: 105 (4), 107 (2), 111, 132, 135, 136, 137, 138, 139, 140, 141, 166,

 176 (2), 200, 233 and 236 (4)

637395-2 for models PE10P-X: 76, 105 (4), 107 (2), 111, 132, 135, 136, 137, 138, 139, 140, 141, 166,

 176 (2), 200, 233 and 236 (4)

Figure 3

101

181

103

201

173 

136

107

 105

236

 137

107

Insert screwdriver here to remove (233) adapter plate.

Notch

PARTS LIST / PX10P-X AIR SECTION

TROUBLE SHOOTING 

Product discharged from exhaust outlet.

Check for diaphragm rupture.
Check tightness of (6) diaphragm washer.

Air bubbles in product discharge.

Check connections of suction plumbing.
Check O” rings between intake manifold and inlet side 
fl uid caps.
Check tightness of (6) diaphragm washer.

Motor blows air or stalls.

Check (176) check valve for damage or wear.
Check for restrictions in valve / exhaust.

y

y

y

y

y

y

y

Low output volume, erratic fl ow, or no fl ow.

Check air supply.
Check for plugged outlet hose.
Check for kinked (restrictive) outlet material hose.
Check for kinked (restrictive) or collapsed inlet material 
hose.
Check for pump cavitation − suction pipe should be sized 
at least as large as the inlet thread diameter of the pump 
for proper fl ow if high viscosity fl uids are being pumped. 
Suction hose must be a non-collapsing type, capable of 
pulling a high vacuum.
Check all joints on the inlet manifolds and suction con-
nections. These must be air tight.
Inspect the pump for solid objects lodged in the dia-
phragm chamber or the seat area.

y

y

y

y

y

y

y

Summary of Contents for PD10P-X

Page 1: ...re Limits diaphragm ball seal material E P R EPDM 600 to 2800 F 510 to 1380 C Hytrel 200 to 1500 F 29º to 660 C Nitrile 100 to 1800 F 12º to 820 C Polypropylene 350 to 1750 F 20 to 790 C PVDF Kynar 100 to 2000 F 120 to 930 C Santoprene 400 to 2250 F 400 to 1070 C PTFE 400 to 2250 F 40 to 1070 C Viton 400 to 3500 F 400 to 1700 C Dimensional Data see page 8 Mounting Dimension 5 032 x 10 050 127 8 mm...

Page 2: ...ervice center that contains hazardous material Safe handling practices must comply with local and national laws and safety code requirements y y y y y y y y y y y y y y y y Obtain Material Safety Data Sheets on all materials from the supplier for proper handling instructions WARNING EXPLOSION HAZARD Models containing aluminum wetted parts cannot be used with 1 1 1 trichloroethane methylene chlorid...

Page 3: ...grounded Flooded suction inlet pressure must not exceed 10 p s i g 0 69 bar y y y y y y y y y y y y OPERATING INSTRUCTIONS Always flush the pump with a solvent compatible with the material being pumped if the material being pumped is subject to setting up when not in use for a period of time Disconnect the air supply from the pump if it is to be inactive for a few hours y y PARTS AND SERVICE KITS ...

Page 4: ...e Qty Part No Mtl Item Description size Qty Part No Mtl 1 Rod 1 95995 C 3 70 Gasket 2 95843 B 5 BackupWasher 2 95990 1 SS 74 Pipe Plug 1 4 18 N P T x 7 16 2 93832 3 K 26 Screw M8 x 1 25 6g x 30 mm 16 95880 SS 76 Pipe Plug 1 8 27 N P T x 27 1 Y17 50 S SS 27 Screw M8 x 1 25 6g x 50 mm 20 96163 SS 131 Screw M8 x 1 25 6g x 100 mm 4 96216 SS 28 Washer 8 5 mm i d 4 96217 SS 3 144 U Cup 3 16 x 1 1 8 o d ...

Page 5: ...n Tan Santoprene Green N A Backup PTFE White White Viton Yellow Yellow 1 TORQUE REQUIREMENTS LUBRICATION SEALANTS Lubriplate FML 2 is a white food grade petroleum grease Apply Lubriplate FML 2 grease to all O rings U cups mating parts Apply Loctite 242 to threads at assembly Apply anti seize compound to threads and bolt and nut flange heads which contact pump case when using stainless steel fasten...

Page 6: ... 4 0 4 5 Nm 4 Install 140 valve insert and 141 valve plate into 135 valve block NOTE Assemble 140 valve insert with dished side toward 141 valve plate Assemble 141 valve plate with part number identification toward 140 valve insert 5 Assemble 200 gasket and 233 adapter plate to 135 valve block NOTE Assemble 233 adapter plate with notched side down 6 Assemble 132 and 166 gaskets and 176 checks and ...

Page 7: ...R SECTION TROUBLE SHOOTING Product discharged from exhaust outlet Check for diaphragm rupture Check tightness of 6 diaphragm washer Air bubbles in product discharge Check connections of suction plumbing Check O rings between intake manifold and inlet side fluid caps Check tightness of 6 diaphragm washer Motor blows air or stalls Check 176 check valve for damage or wear Check for restrictions in va...

Page 8: ...R PX10P AXS BXS 14 7 32 361 2 mm 14 27 32 376 5 mm 2 50 8 mm 2 3 8 59 7 mm 14 11 32 364 0 mm PX10P FXS XXX 16 1 32 407 3 mm 16 1 32 407 0 mm 4 1 16 103 0 mm 16 1 32 407 3 mm PX10P YXS XXX 14 7 32 361 2 mm 16 406 3 mm 1 1 32 25 6 mm 2 3 8 59 7 mm 14 11 32 364 0 mm Figure 4 B D K C A P Q N G L H M J F E R Air Inlet 1 4 18 N P T PX10P FXS XXX PX10P AXS XXX PX10P BXS XXX Outlet Inlet B D K C A P Q N G...