ARO 66610X-X-C Series Operator'S Manual Download Page 8

Page 8 of 8 

66610X-X-C

                                  PN 97999-100

(Dimensions shown are for reference only, they are displayed in inches and millimeters (mm).

8”

(203 mm)

12-1/2”

(318 mm)

11-9/16”

(294 mm)

8-9/16”

(217.5 mm)

4”

(102 mm)

1-1/4”

(32 mm)

7-5/16”

(186 mm)

Air Inlet

1/4 - 18 NPTF -1

13/32” Slot

    (10 mm)

Figure 5

6-1/4”

(159 mm)

6-1/2”

(165 mm)

Outlet

Inlet

1- 11 1/2 NPTF -1 (66610X, 66611X)

Rp 1 (1 - 11 BSP parallel) (66612X, 66613X)

1- 11 1/2 NPTF -1 (66610X, 66611X)

Rp 1 (1 - 11 BSP parallel) (66612X, 66613X)

 TROUBLE SHOOTING

Product discharged from exhaust outlet.

 

y

Check for diaphragm rupture.

 

y

Check tightness of diaphragm nut.

Air bubbles in product discharge.

 

y

Check connections of suction plumbing.

 

y

Check “O” rings between intake manifold and fluid caps.

 

y

Check tightness of diaphragm nut.

Low output volume, erratic flow, or no flow.

 

y

Check air supply.

 

y

Check for plugged outlet hose.

 

y

Check for kinked (restrictive) outlet material hose.

 

y

Check for kinked (restrictive) or collapsed inlet  

material hose.

 

y

Check for pump cavitation − suction pipe should be sized 

at least as large as the inlet thread diameter of the pump 

for proper flow if high viscosity fluids are being pumped. 

Suction hose must be a non-collapsing type, capable of 

pulling a high vacuum.

 

y

Check all joints on the inlet manifolds and suction con-

nections. These must be air tight.

 

y

Inspect the pump for solid objects lodged in the dia-

phragm chamber or the seat area.

DIMENSIONAL DATA

Summary of Contents for 66610X-X-C Series

Page 1: ...Acetal 10 to 180 F 12 to 82 C E P R EPDM 60 to 280 F 51 to 138 C Hytrel 20 to 180 F 29 to 82 C Neoprene 0 to 200 F 18 to 93 C Nitrile 10 to 180 F 12 to 82 C Polypropylene 35 to 175 F 2 to 79 C Polyurethane 10 to 150 F 12 to 66 C Kynar PVDF 10 to 200 F 12 to 93 C Santoprene 40 to 225 F 40 to 107 C PTFE 40 to 225 F 4 to 107 C Viton 40 to 350 F 40 to 177 C Dimensional Data see page 8 Noise Level 70 p...

Page 2: ...em by opening dispensing valve or device and or carefully and slowly loosening and removing out let hose or piping from pump WARNING HAZARDOUS MATERIALS Can cause serious injury or property damage Do not attempt to return a pump to the factory or service center that contains hazardous material Safe handling practices must comply with local and national laws and safety code requirements y y Obtain ...

Page 3: ...tion from dirt and foreign matter during service disassembly and reassembly y y Keep good records of service activity and include pump in preventive maintenance program y y Before disassembling empty captured material in the outlet manifold by turning the pump upside down to drain material from the pump FLUID SECTION DISASSEMBLY 1 Remove top manifold s 2 Remove 22 balls 19 O rings and 21 seats 3 R...

Page 4: ... 637119 X4 C 93459 4 2 T 92973 B 2 SP Y328 14 4 T Y328 126 4 T XX6 48495964 48490056 2 CP Y328 126 4 T XX9 637119 XX9 C 637119 X9 C 90533 9 2 H Y328 14 4 T Y327 126 4 V XXB 637119 XXB C 637119 XB C 90533 B 2 SP Y328 14 4 T 90534 4 E MANIFOLD FLUID CAP MATERIAL OPTIONS 6661XX XXX C Aluminum 6661X0 X 6661XA X Stainless Steel 6661X1 1X9 1XB 1XD Cast Iron 6661X2 X 6661XC X NPTF BSP NPTF BSP NPTF BSP I...

Page 5: ... White Urethane N A Red Viton Yellow Yellow Stripe Dot See item 8 in inset below TORQUE REQUIREMENTS NOTE DO NOT OVERTIGHTEN FASTENERS 14 Bolt 25 30 ft lbs 33 9 40 7 Nm 26 Bolts and 29 nuts 120 140 in lbs 13 6 15 8 Nm LUBRICATION SEALANTS Apply Loctite 271 to threads Apply Key Lube to all O rings U Cups mating parts Apply anti seize compound to threads and bolt and nut flange heads which contact p...

Page 6: ...will force the 109 piston out Continue pushing the 111 spool and remove Check for scratches and gouges 3 Reach into the air section exhaust side and remove 116 spacer 115 spacers 113 O rings 114 O rings 112 washers etc Check for damaged O rings MAJOR VALVE REASSEMBLY 1 Replace 112 washer 114 O ring and 113 O ring onto 115 spacer and insert etc NOTE Be careful to orient spacer legs away from blocki...

Page 7: ...EGS AWAY FROM BLOCKING INTERNAL PORTS WHEN REASSEMBLING AIR SECTION MAJOR VALVE CROSS SECTION DETAIL 109 110 112 114 113 115 111 116 Figure 3 Figure 4 124 TORQUE REQUIREMENTS NOTE DO NOT OVERTIGHTEN FASTENERS 105 40 50 in lbs 4 5 5 6 Nm LUBRICATION SEALANTS Apply Key Lube grease to all O rings U Cups mating parts Apply Loctite 271 to threads Apply Loctite 262 to threads Apply Loctite 572 to thread...

Page 8: ...Check connections of suction plumbing y y Check O rings between intake manifold and fluid caps y y Check tightness of diaphragm nut Low output volume erratic flow or no flow y y Check air supply y y Check for plugged outlet hose y y Check for kinked restrictive outlet material hose y y Check for kinked restrictive or collapsed inlet material hose y y Check for pump cavitation suction pipe should b...