Belgrado
English
05060091 02 14/05/2010
19
1. Introduction - Purpose of the manual/Application field
This instruction manual refers to the
Belgrado
refrigerated cabinets.
The information that follows provides indications relating to:
- Use of the cabinet - technical features- installation and assembly - information for the operator in
charge of use - maintenance interventions.
This manual is to be considered part of the cabinet and must be preserved for its entire duration.
The manufacturer cannot be held responsible for:
- Improper use of the cabinet - incorrect installation not carried out in compliance with the standards
indicated - electric power supply faults - lack of envisioned maintenance - unauthorised modifications
and interventions - use of non original spare parts - partial or total non observance of the instructions.
This manual must be available at all times for consultation by the operators and the staff in charge of
maintenance. In case of transfer to third parties, this manual must be provided to the new user or
owner. The supplier must also be informed of the transfer.
In case of damage or loss, request a copy from the supplier.
N.B.Electric appliances may be dangerous for ones health. Regulations and existing laws in
force must be respected during installation and use.
Whoever uses this cabinet must read this manual.
2. Presentation - Declared use (Fig. 1)
The
Belgrado
refrigerated cabinets is a serve over cabinets line suitable for preserving and selling deli
meats, milk products, gastronomy and meat products prepared for nourishment with a remote conden-
sing unit.
3. Regulations and certifications
All the refrigeration unit models described in the usage manual for the
Belgrado
series meet the
essential requirements for safety, health, and protection required by the following European directives
and laws:
- Machines Directive 2006/42 EC;
harmonised standards applied: EN ISO 14121:2007; EN ISO 12100-1:2005; EN ISO 12100-2:2003
- Electromagnetic Compatibility Directive 2004/108/EC;
harmonised standards applied: EN 61000-3-2:2006; EN 61000-3-12:2005; EN 55014-1:2006;
EN 55014-2:1997;
- Low Voltage Directive 2006/95/EC;
harmonised standards applied: EN 60335-1:2008; EN 60335-2-89 :2002/A2:2007
European Regulation
EC-1935/2004
on materials and articles intended to come into contact with food
- standards applied: EN 1672-2
They are excluded from the field of application of Directive
EEC 97/23 (PED)
on the basis
of that
specified by Article 3 paragraph 3 of the Directive.
A copy of the declaration of product conformity can be requested by filling in the form available
at the internet address:
http://
www.arneg.it/conformity
The performance of these refrigerated units has been determined by means of tests carried out in
accordance with standard
UNI EN ISO 23953-2: 2006
in the environmental conditions corresponding
to climate class 3 (25 °C , 60% Rel. Humidity)
Environmental climatic classes according to UNI EN ISO 23953 - 2
4. Identification - Plate data (Fig. 2)
On the back of the cabinets a plate with the following characteristics data is present:
1) Name and address of the manufacturer
2) Name and length of the cabinet
3) Cabinet code number
4) Cabinet serial number
5) Supply voltage
Climatic class
Temp. dry bulb
Relative humidity
Dew point
1
16°C
80%
12°C
2
22°C
65%
15°C
3
25°C
60%
17°C
4
30°C
55%
20°C
5
40°C
40%
24°C
6
27°C
70%
21°C