INSTALLATION GUIDE
DO NOT
apply heat near this product. Heat generated by soldering
could damage plastic parts and seals.
5.1
Mounting
Before connection, flush water through pipe-work to
remove all debris etc. to prevent damage to the valve
mechanism.
THEN ENSURE WATER SUPPLIES HAVE BEEN
ISOLATED.
2.
Fit the two rubber mouldings onto the metal fixing plates. Then from behind the panel slide the fixing
plate assemblies onto the fixing studs as shown.
3.
Hand tighten the nuts against the fixing plates until the rubber mouldings make contact with the rear
of the panel. Ensure the spout & sensor are positioned correctly, & then tighten the nuts securely with
a 13mm A/F spanner.
CABLE COLOURS:
The cables emerging from the spout are connected to the integral sensor.
BLACK & RED cables will connect to the solenoid valve.
GREY cable will connect onto the PCB inside the PSU
Do not cut these cables
.
DRILL PANEL
HOLE Ø25
& Ø30
1
1
2
3
13
INSTALLATION HEIGHT: we recommend the spout outlet be positioned approximately 150-200mm
above the basin or worktop (which ever is higher). Greater height may cause users to splash water out-
side the basin whereas lower height may affect activity space. Consideration should also be give to the
overall aesthetical appearance. Installations vary significantly, so use this dimension as a guideline only.
1.
Screw the copper inlet pipe into the spout,
trim to length if necessary. Ensure the foam
gaskets are in place as shown. These gaskets
should already be fitted into the recess at the
rear of the spout & sensor (self adhesive). The
M8 fixing studs should also be pre-fitted. Offer
the spout towards the upper hole in the panel.
Mark the position of the spout onto the panel at
the preferred location & drill a hole Ø30. Mark the
position of the sensor onto the panel approximately
80 to 90mm below the spout centre line. Drill a
hole Ø20. Upper hole is for the spout fixing stud &
inlet pipe. Lower hole is for the sensor fixing stud &
cables. Ensure the holes remain within the areas
sealed by the foam gaskets.
Feed the inlet pipe & fixing stud through the
panel hole. Push the spout against the panel &
ensure the foam gasket makes contact. Simi-
larly offer the sensor towards the lower panel
hole, push the fixing stud & cables through &
park it against the panel.