6
5
INSTALLATION GUIDE
SENSOR POSITIONING:
An example of a typical
sensor operated shower
installation is shown here.
IMPORTANT:
We recommend the sen-
sor be positioned to one
side of the shower outlet
& within easy reach of
the user.
AVOID positioning the
sensor directly beneath
the shower outlet.
Sensor range is factory
set to approximately
100mm
Sensor height:
The height of the sensor
from the floor can be waist
height approximately 1M.
Sensor offset:
The sensor centre line
should be offset by at
least 250mm to either side
of the shower outlet
centre line as shown.
Otherwise the sensor will
be triggered repeatedly
by the user during show-
ering.
100
Greater than 250
SENSOR SHOULD NOT BE LOCATED DIRECTLY OPPOSITE A WALL MIRROR.
Ideally pipe-work, cables & electrical parts should be located behind a panel
away from the shower water.
ALTERNATIVELY, extension leads are supplied which permit the PSU & solenoid valve to
be fitted in the ceiling – up to 2M from the sensor location.
!
Figure 5a