TABLE OF CONTENT
1 IMPORTANT PRE-INSTALLATION NOTES ................................... 4
2 PRODUCT BOX CONTENTS ......................................................... 5
3 SUPPLY CONDITIONS .................................................................... 6
3.1 WATER REGULATIONS .....................................................................................6
3.2 CATEGORIES OF RISK .....................................................................................6
4 URINAL PLUMBING ARRANGEMENTS ........................................ 6
5 INSTALLATION GUIDE .................................................................... 9
5.1 MOUNTING SENSORS ......................................................................................9
5.2 PLUMBING OVERVIEW ...................................................................................10
5.3 ELECTRICAL CONNECTION ..........................................................................13
6 URINAL OPERATION .................................................................... 18
7 SENSOR RANGING & RUN TIME ADJUSTMENT ..................... 19
8 EXTENSION CABLES ................................................................... 20
9 MAINTENANCE ..............................................................................20
9.1 SOLENOID VALVE ............................................................................................20
9.2 HYGIENE FLUSH (AUTOMATIC) ....................................................................21
10 CLEANING CHROME SURFACES ............................................... 22
11 SPARE PARTS ...............................................................................23
Sensorflow 21 compact high pressure
mains water urinal flushing device
These compact panel (PM) Sensorflow 21 electronic urinal flushing products is designed for water
economy & hygienic “no-touch” operation.
The urinal flush is operated by the infrared sensor which detects the presence of the user in the sensing re
-
gion. When the user moves away, the flush is triggered automatically. Water will flow for the preset run-time.
These products is intended to be supplied with cold water only.
The products is available in 2 versions: Mains powered (transformed) with option to link up to 5 link units
A7001..
(PM) is supplied with
mains power unit
A7002..
(PM) is supplied with
link unit
One mains unit (A7001..) can power up to five link units (A7002..)
Abbreviations & terminology used
PSU: P
ower
S
upply
U
nit, either mains, battery or link versions.
PCB: P
rinted
C
ircuit
B
oard inside the PSU.
RCD:
R
esidual
C
urrent
D
evice
SELV: S
afety
E
xtra
L
ow
V
oltage
LINK
PSUs: (up to 5 max) can be connected in series to a single mains PSU.
Permitting washroom with multiple products to be run from a single mains supply point.
PM:
P
anel