Armitage Shanks A4125AA Installation Instructions Manual Download Page 1

Important:

1. Electrical connection:  

mains electric powered version of this 

     product must be connected to a continuous permanent power supply.

   

2. Sensor protector:  

this black-out lens cover should only be removed from

    the sensor after completing installation & at least 20 seconds after powering up.

See page 3 for more details.

INSTALLER:

  

After installation please pass this instruction booklet to user

IMPORTANT

BEFORE CONNECTION, FLUSH WATER THROUGH PIPEWORK TO REMOVE

ALL DEBRIS ETC. WHICH COULD DAMAGE THE VALVE MECHANISM

750mm

max. 350

150

26,5

113

40

15°

Ø10

Ø15

Ø15

Ø15

Ø15

Ø15

Ø20

171

max.35

Ø35

67

40

61

103

86

116

Sensorflow 21 panel mounted

spouts A4125AA, A4178AA & A4179AA

INSTALLATION 

INSTRUCTIONS

www.divapor.com

Summary of Contents for A4125AA

Page 1: ...st 20 seconds after powering up See page 3 for more details INSTALLER After installation please pass this instruction booklet to user IMPORTANT BEFORE CONNECTION FLUSH WATER THROUGH PIPEWORK TO REMOVE ALL DEBRIS ETC WHICH COULD DAMAGE THE VALVE MECHANISM 750mm max 350 150 26 5 113 40 15 Ø10 Ø15 Ø15 Ø15 Ø15 Ø15 Ø20 171 max 35 Ø35 67 40 61 103 86 116 Sensorflow 21 panel mounted spouts A4125AA A4178A...

Page 2: ...rflow 21 electronic products are designed for water economy hygienic no touch operation The spout is operated by the integral infrared sensor which is triggered by hand movement in the sensing region When the hands are moved away the water will stop automatically within a couple of seconds These products are designed to be supplied with pre mixed or cold water The spout has a reach from panel of 1...

Page 3: ...s are in trinsically economical in terms of both water and electrical energy and will shut down in the event of a sensor being obstructed SENSOR PROTECTIVE COVER This product is supplied with the sensor lens covered over with a black out material DO NOT REMOVE this lens cover until the product installation has been completed then wait for at least 20 seconds after powering up The lens cover preven...

Page 4: ...ers 1x copper inlet pipe 1x foam gasket 2x Couplers G 1 2 female thread to 15 mm compression 1x Inlet elbow 15 to 10mm compression Each type of PSU is identified by this coloured dot system RED DOT BLUE DOT GREEN DOT MAINS LINK Supplied with link cable BATTERY Supplied with battery 1x Sensorflow 21 compact spout with integral sensor Regulated PCA outlet pre fitted See section 8 w w d i v a p o r c...

Page 5: ...ccordance with the water regulations published in 1999 therefore Armitage Shanks would strongly recommend that these fittings are installed by a professional installer A guide to the Water Supply Water Fittings Regulations 1999 and the Water Byelaws 2000 Scotland is published by WRAS Water Regulations Advisory Scheme Fern Close Pen y Fan Industrial Estate Oakdale Newport NP11 3EH ISBN 0 9539708 0 ...

Page 6: ...ely with a 13mm A F spanner 1 Screw the copper inlet pipe into the spout trim to length if necessary Ensure the foam gasket is in place as shown This gasket should already be fitted into the recess at the rear of the spout self adhesive The M8 fixing stud should also be pre fitted Offer the spout towards the holes in the panel Feed the inlet pipe fixing stud cables through panel holes Push the spo...

Page 7: ... from below but can be from any direction Short lengths of Ø15mm copper pipe not supplied have been used between the components Copper pipe lengths should be cut to suit the installation Note the Ø10mm inlet pipe fitted to spout can be trimmed if necessary Observe arrow markings on the valves as shown here Ensure water flows in the direction indicated 4 To fit inlet elbow Slip the small compres si...

Page 8: ...are not to use excessive force Tighten with an adjustable spanner 25mm A F 7 9 Slip the compression nuts olives onto the pipes Fit the solenoid valve into the pipe work make good the joints Observe flow direction Make sure the solenoid valve is orientated such that the electrical connectors are easily accessible 10 11 To fit service valve Slip the compression nuts olives onto the pipes Fit the ser...

Page 9: ...he spout attached to the rear of the sensor This cable length is nominal 800mm Connect the cable to the solenoid valve terminals as shown Observe the and symbols marked on the solenoid valves connect the red cable to black to Refer to the diagram on the next page for PSU connection options 12 red black Power 6W Approval EU EN 60950 EN 60335 Approval UL UL 1310 Input voltage 100V 240V 50 60Hz Prote...

Page 10: ...ible cable through this grommet make connections to terminal block on the PCB Refer to 28 19 For link version feed the link cable through the side wall grommet in the PSU plug it onto one of the sockets on the PCB Refer to 28 ALTERNATIVELY the link cable can be routed through the PSU lid as shown in 24 along with the sensor cable 20 Slide the PCB back into the PSU ensuring cables are not trapped 2...

Page 11: ...BLUE DOT GREEN DOT MAINS LINK BATTERY 24 Remove the pre split grommet from the PSU lid Slide the grey sensor cable into this grommet 25 Slide the sensor cable terminal through the PSU lid plug into one of the sockets on the PCB Press grommet securely into the lid 26 Mate the PSU lid to the PSU case ensuring seal is in place Avoid trapping any cables 27 Refit the 4 lid screws securely w w d i v a p...

Page 12: ...d valve GREY cable with black line will plug into one of the sockets on the PCB inside the PSU Link cable is also GREY with black line length is 1 5M supplied with link product only SEE SECTION 7 FOR CABLE EXTENSION DETAILS FURTHER CABLE NOTES lid screw grommet for sensor cable lid PCB terminal block for mains connection transformers with thermal fuse complies with EN60950 lid seal PSU case gromme...

Page 13: ...on does not stretch stress the cables Consideration should also be given to keeping the PSU case within easy reach access for maintenance staff IMPORTANT Leave the sensor protective sticker in place for at least 20 seconds after powering on the product See section 7 regarding sensor ranging Example above of an installation where PSUs are all battery versions Example of an installation where 1st PS...

Page 14: ...ggered by something reflective normally hand movement in the Sensing Region Move hands towards the spout Water will flow Move hands away from the spout Water will continue to flow for a second or two and then turn off Sensor is factory set to Proximity Mode is designed to trigger the water flow only when a hand or similar is in the Sensing Region just in front of the sensor outlet For this range o...

Page 15: ...ode see section 10 See maintenance section for a quick overview of how to use this unit to evoke the optional hygiene flush function 7 SENSOR RANGING For more information on spare parts why not visit our spare website www fastpart spares co uk Or contact customer care fast t r a p Extension cables Default factory range setting is 145mm DURING SETTING UP PROCEDURE AVOID HIGH VISIBILITY CLOTHING CAB...

Page 16: ... housing with the key ensuring the seal is in place Ensure the outlet housing is adequately tightened to prevent leaks run back If water continues to flow when the tap should be off and if the sensor is correctly ranged then the solenoid valve may have debris lodged in the diaphragm pilot hole or on the valve seat Locate the solenoid valve Isolate the water supplies Disconnect the solenoid valve c...

Page 17: ... programming unit should be held pointing towards the sen sor at distance of approx 100mm Once enabled this function will automatically turn the water on for a duration of 1 to 240 seconds if the product has not been used for a period of 6 12 24 48 or 72 hours This hygiene flush is an important optional function of these products which can be enabled by the in staller or maintenance staff using th...

Page 18: ...UP FUNCTION previous settings are Remembered just point at next Tap Sensor and press ENTER to repeat l Hand unit turns itself off after 2 minutes of non use A brief summary of how to navigate the programming unit is as follows 9 3 Isolating valve strainer cap strainer screen isolating valve direction of flow Isolation valve supplied with this product MUST be fitted to permit future maintenance of ...

Page 19: ...62 881 NU PSU AC complete A 960 531 NU PSU Link complete A 960 551 NU PSU Battery complete E 960 086 NU FOR LONGER CABLE OPTIONS REFER TO SECTION 7 B 960 459 NU F 960 970 NU B 960 860 NU Flow straightener insert A 960 219 NU Sensor complete A 961 182 NU O ring only x2 X X B 960 859 AA Areator complete with AV key For more information on spare parts why not visit our spare website www fastpart spar...

Page 20: ...erved to vary specification without notice Armitage Shanks is a division of Ideal Standard UK Ltd Armitage Shanks The Bathroom Works National Avenue Kingston upon Hull HU5 4HS England For more information about our products visit our websites www armitage shanks co uk www idealspec co uk www fastpart spares co uk Outlet cleaning On a regular basis the outlet should be inspected cleaned To unscrew ...