7
5.2
Plumbing Overview
Once the spout has been secured to the ba-
sin, consideration should be given to install-
ing & positioning of the inline valves.
A typical plumbing installation example is
shown here. The water is being supplied from
below, but can be from any direction.
Short lengths of Ø15mm copper pipe
(not supplied) have been used between the
components. Copper pipe lengths should be
cut to suit the installation.
Note the Ø10mm inlet pipe (fitted to spout)
can be trimmed if necessary.
Observe arrow markings on the
valves as shown here. Ensure water
flows in the direction indicated.
4. To fit inlet adaptor:
Slip the small com-
pression nut & olive onto the Ø10mm inlet
pipe. Push the adaptor onto the inlet pipe up
to the shoulder. Slide the olive up to the adap-
tor & tighten the compression nut
(17mm A/F) with an adjustable spanner. Hold
the adaptor steady with 22mm A/F spanner.
INSTALLATION GUIDE continued…
Copper supply
pipe Ø 15mm
Short copper
pipe Ø 15mm
Short copper
pipe Ø 15mm
Spout inlet
pipe Ø 10mm
Inlet adaptor
15 to 10mm
compression
Inline service
valve with filter
Inline
solenoid
valve
Filter
cap
Isolation
screw
2x Couplers
G1/2” female
thread to
15mm
compression
FLOW
DIRN
FLOW
DIRN
17, 22 & 24
4
5