Armcor XEM 500 Installation & Operation Manual Download Page 9

Armcor Air Solutions

109-111 Northcorp Blvd, Broadmeadows 3047

P

  1800 244 556 

E

 [email protected]

www.armcor.com.au

Date:  20/10/2016 

Document:  XEM Installation Manual  

Version Number: 

V2

XCHANGE ERV CEILING MOUNT

EXTERNAL MOUNT UNITS

XEM - INSTALLATION & OPERATION MANUAL

The standard Armcor warranty policy is a parts only 
warranty for a 12 month period. If any defect in your Armcor 
equipment is caused by FAULTY MATERIALS within the 
warranty period, starting from the date of original purchase 
it will be rectified or replaced without cost.

Additional labour warranty is available and must be 
purchased at the time of ordering in accordance with the 
warranty policy.

•  Consequential damage

•  Failure to start due to voltage conditions, blown fuses 

or other damage cause by inadequate or interrupted 
electricity supply

•  Damage caused by accident, misapplication, abuse, 

alteration, tampering or servicing by anyone other than 
an authorized person

•  Damage resulting from incorrect installation, 

commissioning or use other than in accordance with the 
installation and operating instructions issued by Armcor 
Air Solutions

•  Damaged caused by using equipment being located in a 

corrosive atmosphere or by filter neglect

•  Replacement of any worn drive belts if applicable

•  Costs incurred for regular maintenance services

•  The original service call costs in identifying a warranty 

claim

•  Freight and travel changes for work performed or parts 

supplied outside of all capital cities in Australia

•  Field wiring, refrigerant pipe run between units, the 

condensation drainpipe or other accessories

•  Any warranty work performed by Armcor Air Solutions 

outside of Melbourne metro area will require the installing 
contractor to provide free of charge: Oxy/Acetylene 
Equipment, Dry Nitrogen, Vacuum Pump, Refrigerant Gas, 
Reclaim Bottles, Recovery Unit, and any other associated 
refrigerant tools.

•  Any appliance plate is altered or removed

•  Armcor Air Solutions has not be notified within 48 hours 

of any fault occurring which may require warranty work

•  Any unauthorized modification has been made to the 

equipment or any part has be substituted or replaced 
with non-original items

•  Regular service has not been carried out by an appropriate 

Armcor approved, licenced installer

•  The unit is used other than for the heating and cooling 

of air for human comfort – unless approved by Armcor 
Air Solutions

•  The system is installed in a mobile application (eg. 

caravan, boat, crane)

Complete a warranty form available on our website www.armcor.com.au and return the Armcor Warranty Request Form 
to: [email protected]
Contact us direct by phone on 1800 244 556 or email [email protected]

WHAT THE WARRANTY POLICY COVERS

WHAT THE WARRANTY POLICY DOES NOT COVER

THE WARRANTY WILL NOT APPLY IF;

HOW TO MAKE A WARRANTY CLAIM

WARRANTY

7

The Armcor Air Solutions Warranty Policy should be read in conjuction with the 
Terms and Conditions of Sale. These are available on our website - www.armcor.com.au.

Summary of Contents for XEM 500

Page 1: ...XEMINSTALLATION OPERATIONMANUAL XCHANGEERV EXTERNALMOUNT XEM500 XEM900 XEM1200 XEM1700 XEM2000 XEM2500 XEM3500 XEM4500 XEM5000 XEM6000 XEM7000 XEM8000 ...

Page 2: ......

Page 3: ...ge media are available Every proposed installation must be subject to an engineered design by a mechanical services consultant Armcor Air Solutions is not responsible for performance of equipment in applications for which the equipment was not designed or specified Only trained and qualified personnel should install repair or service heat recovery and or air handling equipment Installing and servi...

Page 4: ...e pad to be used under the base frame and flexible couplings be fitted to the supply and return ducts to reduce any vibration transfer The location of the fresh air inlets must adhere to the Australian Standards 1668 2 The fresh air intake should be positioned clear of any objects which could obstruct the airflow and be a minimum distance of 6 metres from any exhaust discharge ducts from this unit...

Page 5: ...NOTE All units should be lifted into position using SLINGS and not CHAINS Chains may damage exterior finish on the fan unit Where units have to be craned into position installers must check unit weight is within the safe tolerance of the working capacity of the crane Prepare for lifting with spreaders as you would do with lifting air conditioning equipment When lifting equipment never stand under ...

Page 6: ...construction and commissioning Where a Heat Exchanger is incorporated in the equipment warranty is void if filters are not fitted IMPORTANT NEVER OPERATE A UNIT WITHOUT FILTERS FITTED TO THE RETURN AND FRESH AIR INTAKES The power requirement and voltage are detailed on the equipment technical specifications available on our website www armcor com au and are on the identification serial no plate at...

Page 7: ...ailable for units fitted with Certrifugal Fans OPTION 1 AND 2 DO NOT REQUIRE ANY CHANGES TO THE FAN POSITIONS INSIDE THE UNIT RETURN AIR Air that is drawn from conditioned area EXHAUST AIR Ducted to outside the building or into the roof space if adequate ventilation is available FRESH AIR Use a fresh air cowl or grill to introduce fresh air SUPPLY AIR Connect to the Airconditioning system or direc...

Page 8: ...eaned once a month and the filter media should be replaced every 12 months Repeat the monthly schedule Check blower wheels for dirt build up and tightness on shaft Check all cabinet panels for correct fitting alignment and seals and clean cabinets as required Ensure no insulation has been detached from the panels All electrical terminals should be checked for tightness IMPORTANT Ensure the with ma...

Page 9: ... and travel changes for work performed or parts supplied outside of all capital cities in Australia Field wiring refrigerant pipe run between units the condensation drainpipe or other accessories Any warranty work performed by Armcor Air Solutions outside of Melbourne metro area will require the installing contractor to provide free of charge Oxy Acetylene Equipment Dry Nitrogen Vacuum Pump Refrig...

Page 10: ...ons Ensure supply cable is correct size Check the required supply voltage is available on all phases Check overload settings are correct if applicable FILTERS Check that both the fresh air and return air have adequate filters before starting unit STARTING UNIT Check Fans and Air Flows Turn on all circuit breakers Make sure all dampers are open Turn on control circuit and activate fans Turn on supp...

Page 11: ...rn Air Flow Total of all inlets L s Total System external resistance Pa Measured downstream of fan outlets plus upstream of Coil s Estimate of Fresh Air Make Up or L s ELECTRICAL Supply Voltage Supply Unit Fan Motor Amps Exhaust Fan Motor Amps Total Unit Amps Thermostat Settings ºC Thermostat Operating Correctly Y N Contactors Relays Operating Correctly Y N All Terminals Checked for Tightness and ...