background image

The Armcor Air Solutions Warranty 

Policy should be read in conjunction 

with the Terms and Conditions of 

Sale. These are available on our 

website – 

armcor.com.au

What The Warranty Policy Covers

The standard Armcor warranty policy is a parts only 

warranty for a 12-month period. If any defect in your 

Armcor equipment is caused by 

FAULTY MATERIALS 

within the warranty period, starting from the date of 

original purchase it will be rectified or replaced without 

cost.
Additional labour warranty is available and must be 

purchased at the time of ordering in accordance with 

the warranty policy.

What The Warranty Policy Does 

Not Cover

• 

Consequential damage.

• 

Failure to start due to voltage conditions, blown fuses 

or other damage cause by inadequate or interrupted 

electricity supply.

• 

Damage caused by accident, misapplication, abuse, 

alteration, tampering or servicing by anyone other 

than an authorized person.

• 

Damage resulting from incorrect installation, 

commissioning or use other than in accordance with 

the installation and operating instructions issued by 

Armcor Air Solutions.

• 

Damaged caused by using equipment being located in 

a corrosive atmosphere or by filter neglect.

• 

Costs incurred for regular maintenance services.

• 

The original service call costs in identifying a 

warranty claim.

• 

Freight and travel changes for work performed or 

parts supplied outside of all capital cities in Australia.

• 

Field wiring, refrigerant pipe run between units, the 

condensation drainpipe, or other accessories.

• 

Any warranty work performed by Armcor Air 

Solutions outside of Melbourne metro area will 

require the installing contractor to provide free of 

charge: Oxy/Acetylene Equipment, Dry Nitrogen, 

Vacuum Pump, Refrigerant Gas, Reclaim Bottles, 

Warranty

Recovery Unit, and any other associated refrigerant 

tools.

The Warranty Will Not Apply If;

• 

Any appliance plate is altered or removed.

• 

Armcor Air Solutions has not been notified within 

48 hours of any fault occurring which may require 

warranty work.

• 

Any unauthorized modification has been made to 

the equipment or any part has been substituted or 

replaced with non-original items.

• 

Regular service has not been carried out by an 

appropriate. Armcor approved, licensed installer.

• 

The unit is used other than for the heating and 

cooling of air for human comfort – unless approved 

by Armcor Air Solutions.

• 

The system is installed in a mobile application (e.g., 

caravan, boat, crane).

How to Make a Warranty Claim

Complete a warranty form available on our website 

armcor.com.au 

and return the Armcor Warranty 

Request Form to: 

[email protected]

Contact us direct by phone on 1800 244 556 or email 

[email protected]

16               Armcor_XCM–Compact Multiflow ERV Installation and Operation Manual 2021   

Summary of Contents for XCM1225

Page 1: ...Installation and Operation Manual XCM COMPACT MULTIFLOW ERV XCM125 XCM1225 M ADE A U STRALI A N Manufactured byArmcor M ADE A U STRALI A N Manufactured byArmcor...

Page 2: ...Mains Power Supply and Fusing Equipment Layout 8 OPTIONS FOR EVERY INSTALLATION XCM With Centrifugal Fans General Maintenance 12 General Monthly Maintenance Schedules Guide to How Frequency According...

Page 3: ...I sec Fan Filter Size mm Number of filters Weight kg Dimensions mm H x W x L XCM125P1 125 EC Plug 395 x 245 x 45 2 65 290 x 690 x 920 XCM225P1 225 EC Plug 395 x 395 x 45 2 80 440 x 690 x 920 XCM325C1...

Page 4: ...overy and or air handling equipment Installing and servicing equipment can be hazardous due to electrical and mechanical components When working on equipment observe precautions in all literature tags...

Page 5: ...nlet and Exhaust Air Outlet The location of the fresh air inlets must adhere to the Australian Standards 1668 2 The fresh air intake should be positioned clear of any objects which could obstruct the...

Page 6: ...heck unit weight is within the safe tolerance of the working capacity of the crane Prepare for lifting with spreaders as you would do with lifting air conditioning equipment When lifting equipment nev...

Page 7: ...commissioning IMPORTANT NEVER OPERATE A UNIT WITHOUT FILTERS FITTED TO THE RETURN AND FRESH AIR INTAKES WARRANTY IS VOID IF THE FILTERS ARE NOT FITTED AND REGULARLY CLEANED OR REPLACED Electrical Req...

Page 8: ...conditioned area Exhaust Air Ducted to outside the building or into the roof space if adequate ventilation is available Fresh Air Use a fresh air cowl or grill to introduce fresh air Supply Air Connec...

Page 9: ...ERY Exhaust Air Fresh Air Return Air Supply Air ENERGY RECOVERY Exhaust Air Fresh Air Supply Air Return Air ENERGY RECOVERY Exhaust Air Supply Air Fresh Air Return Air ENERGY RECOVERY Exhaust Air Fres...

Page 10: ...ir ENERGY RECOVERY Exhaust Air Fresh Air Supply Air Return Air ENERGY RECOVERY Exhaust Air Supply Air Return Air Fresh Air ENERGY RECOVERY Exhaust Air Return Air Fresh Air Supply Air ENERGY RECOVERY E...

Page 11: ...Take care not to damage the heat exchange modules Check the fan wiring is connected and will not interfere with fan operation Note On XCM625 and XCM925 the top panel of the unit will need to be remove...

Page 12: ...to Usage is Established Disposable Corrugated Filters Standard disposable corrugated filters should last approximately one month in normal commercial use with 8 hours per day continuous operation or l...

Page 13: ...ltage is available on all phases Check overload settings are correct if applicable Filters Check that both the fresh air and return air have adequate filters before starting unit Starting Unit Check F...

Page 14: ...Air Flow L s Total Fresh Air Inlet Air Flow L s Total System external resistance Pa Measured downstream of fan outlets Estimate of Fresh Air Make Up or L s Electrical Supply Voltage Supply Fan Motor...

Page 15: ...eplace as necessary Dirty contactor controls Clean and or replace Tripped Circuit Breaker Short circuit Trace and correct Earth leakage or over heating cables due to high load Meggar and replace as ne...

Page 16: ...identifying a warranty claim Freight and travel changes for work performed or parts supplied outside of all capital cities in Australia Field wiring refrigerant pipe run between units the condensation...

Page 17: ...Notes Armcor_XCM Compact Multiflow ERV Installation and Operation Manual 2021 17...

Page 18: ...Notes 18 Armcor_XCM Compact Multiflow ERV Installation and Operation Manual 2021...

Page 19: ...compact horizontal low profile heat recovery unit designed for installation within a roof space underfloor or in a plant room Read more here See our product brochure Armcor_XCM Compact Multiflow ERV...

Page 20: ...Fresh Air Indoors For more information W armcor com au E sales armcor com au P 03 8301 9200 109 111 Northcorp Blvd Broadmeadows Vic 3047...