background image

Installation and 

Operation Manual

XCM–COMPACT MULTIFLOW ERV

XCM125 – XCM1225

M ADE

AU

STRALIAN

Manufactured

     by Armcor

M ADE

AU

STRALIAN

Manufactured

     by Armcor

Summary of Contents for XCM1225

Page 1: ...Installation and Operation Manual XCM COMPACT MULTIFLOW ERV XCM125 XCM1225 M ADE A U STRALI A N Manufactured byArmcor M ADE A U STRALI A N Manufactured byArmcor...

Page 2: ...Mains Power Supply and Fusing Equipment Layout 8 OPTIONS FOR EVERY INSTALLATION XCM With Centrifugal Fans General Maintenance 12 General Monthly Maintenance Schedules Guide to How Frequency According...

Page 3: ...I sec Fan Filter Size mm Number of filters Weight kg Dimensions mm H x W x L XCM125P1 125 EC Plug 395 x 245 x 45 2 65 290 x 690 x 920 XCM225P1 225 EC Plug 395 x 395 x 45 2 80 440 x 690 x 920 XCM325C1...

Page 4: ...overy and or air handling equipment Installing and servicing equipment can be hazardous due to electrical and mechanical components When working on equipment observe precautions in all literature tags...

Page 5: ...nlet and Exhaust Air Outlet The location of the fresh air inlets must adhere to the Australian Standards 1668 2 The fresh air intake should be positioned clear of any objects which could obstruct the...

Page 6: ...heck unit weight is within the safe tolerance of the working capacity of the crane Prepare for lifting with spreaders as you would do with lifting air conditioning equipment When lifting equipment nev...

Page 7: ...commissioning IMPORTANT NEVER OPERATE A UNIT WITHOUT FILTERS FITTED TO THE RETURN AND FRESH AIR INTAKES WARRANTY IS VOID IF THE FILTERS ARE NOT FITTED AND REGULARLY CLEANED OR REPLACED Electrical Req...

Page 8: ...conditioned area Exhaust Air Ducted to outside the building or into the roof space if adequate ventilation is available Fresh Air Use a fresh air cowl or grill to introduce fresh air Supply Air Connec...

Page 9: ...ERY Exhaust Air Fresh Air Return Air Supply Air ENERGY RECOVERY Exhaust Air Fresh Air Supply Air Return Air ENERGY RECOVERY Exhaust Air Supply Air Fresh Air Return Air ENERGY RECOVERY Exhaust Air Fres...

Page 10: ...ir ENERGY RECOVERY Exhaust Air Fresh Air Supply Air Return Air ENERGY RECOVERY Exhaust Air Supply Air Return Air Fresh Air ENERGY RECOVERY Exhaust Air Return Air Fresh Air Supply Air ENERGY RECOVERY E...

Page 11: ...Take care not to damage the heat exchange modules Check the fan wiring is connected and will not interfere with fan operation Note On XCM625 and XCM925 the top panel of the unit will need to be remove...

Page 12: ...to Usage is Established Disposable Corrugated Filters Standard disposable corrugated filters should last approximately one month in normal commercial use with 8 hours per day continuous operation or l...

Page 13: ...ltage is available on all phases Check overload settings are correct if applicable Filters Check that both the fresh air and return air have adequate filters before starting unit Starting Unit Check F...

Page 14: ...Air Flow L s Total Fresh Air Inlet Air Flow L s Total System external resistance Pa Measured downstream of fan outlets Estimate of Fresh Air Make Up or L s Electrical Supply Voltage Supply Fan Motor...

Page 15: ...eplace as necessary Dirty contactor controls Clean and or replace Tripped Circuit Breaker Short circuit Trace and correct Earth leakage or over heating cables due to high load Meggar and replace as ne...

Page 16: ...identifying a warranty claim Freight and travel changes for work performed or parts supplied outside of all capital cities in Australia Field wiring refrigerant pipe run between units the condensation...

Page 17: ...Notes Armcor_XCM Compact Multiflow ERV Installation and Operation Manual 2021 17...

Page 18: ...Notes 18 Armcor_XCM Compact Multiflow ERV Installation and Operation Manual 2021...

Page 19: ...compact horizontal low profile heat recovery unit designed for installation within a roof space underfloor or in a plant room Read more here See our product brochure Armcor_XCM Compact Multiflow ERV...

Page 20: ...Fresh Air Indoors For more information W armcor com au E sales armcor com au P 03 8301 9200 109 111 Northcorp Blvd Broadmeadows Vic 3047...

Reviews: