10
11
TROUBLE SHOOTING
GBIN004058
GBIN004058
PROBLEM
CAUSE
SOLUTION
The unit does not come ON.
Unit not plugged in.
Make sure the plug is pushed in
completely and power switch is
switched ON.
Internal safety device has operated.
Wait for 30mins and try again.
Wall socket is not working.
Check with another working
wall socket.
Battery in the remote control need to
be replaced.
Change remote batteries.
Water-full indicator turns on.
Drain water out.
Machine auto-restarts
frequently
Direct sunlight
Draw the curtains
Door and windows are open,
many heat sources in the room.
Close the door and windows,
move out heat sources.
Filters are too dirty.
Clean or replace filters
Air-inlet or air-outlet is blocked
Remove blockage
Unit works for a short
time only.
Bends or kinks in the air Exhaust Hose.
Position the hose properly, keeping it
as short as possible with no bends.
Air outlet/inlet grilles are blocked.
Visual inspect the unit to make sure
no foreign material is obstruction the
airflow.
Unit does not cool the room.
Room size too large.
Unit is suitable for a room size of
24m
2
with a standard ceiling height
of 2.4m.
Direct sunlight onto the unit.
Close curtains and pull down blinds.
Windows or doors open.
Close doors and windows.
Another heat source in the room.
Eliminate all other heat sources.
Outlet duct venting the hot air properly.
Adjust the hose properly so that
there is no back flow of hot air in
the room.
Room temperature below your
selected temperature.
Adjust the room temperature.
Unit is too noisy.
Unit placed on a hard surface
causing it to vibrate.
A soft carpeted surface may absorb
excessive vibration.
The unit does not operate
for about three minutes after
it is restarted.
This is for the safety of the compressor
which prevents the unit from being
restarted until three minutes have
elapsed since it was last turned off.
This is part of normal operation.
If the machine will not be used for a long time.
1.
Pull the drain cap out, drain the water in the water tray to another vessel that holds water.
2.
Ensure the tilt angle of the unit shall not be greater than 30 degrees.
3.
Start the unit, turn the mode to the low fan speed state of the air supply mode, keep this state for half a
day and will dry the interior of the unit to prevent mold.
4.
Turn off the unit, unplug the power plug, wrap the power cord, install the water plug and drain cap.
5.
Remove the heat exhaust duct assembly and keep it properly.
6.
Clean and dry filters, then reinstall them.
7.
Pack the air-conditioner properly with soft plastic bag to protect from dust. Put the unit in a dry place,
away from direct sunlight.
8.
Keep the unit out of the reach of children.
9.
Take out the batteries of the remote control and keep it properly.
Note: Ensure that the unit is put in a dry place. All accessories of the unit should be stored
in a secure place.
SEASON CLEANING
MAINTENANCE
•
Please pull out plug before cleaning.
•
Use soft semi-dry cloth to clean the machine. Don’t use chemical agents, such as benzene, alcohol,
gasoline and so on. Otherwise the machine surface will be damaged, or even the machine itself.
•
Don’t spatter water into the machine.
If the filter screen is clogged with
dust, and the effectiveness of the air
conditioning is reduced, be sure to clean
the filter screen once every week of
operation.
Clean the upper filter screen frame:
1. Detach the filter by holding the locking
clip and pushing it outwards.
2. Once the filter assembly is taken out
from the assembly. Remove the filter
frame place inside the assembly.
Please apply minimum force during
the process as the filter frame nets are
delicate in design.
3. Use vacuum cleaner to remove the
dust from the filter frame. If the frame
is very dusty; place it in the warm
water under 40°C or 104°F to which
neutral detergent is added for cleaning
and then dry them in the shade. Rinse
the filter and dry it in a shaped place.
NOTE: Don’t run the machine without
filters. Do not damage the
mesh fabric on the filter frame
and filter mesh.
Prior to maintenance and servicing of the unit, turn off the power and unplug the plug to avoid
electric shocks.
SURFACE CLEANING
CLEANING THE INTAKE GRILLES AND EVAP FILTER
Locking
Clip
Locking
Clip