Arlec PA1201GB Instruction Manual Download Page 6

10

11

TROUBLE SHOOTING

GBIN004058

GBIN004058

PROBLEM

CAUSE

SOLUTION

The unit does not come ON.

Unit not plugged in.

Make sure the plug is pushed in 
completely and power switch is 
switched ON.

Internal safety device has operated.

Wait for 30mins and try again.

Wall socket is not working.

Check with another working  
wall socket.

Battery in the remote control need to 
be replaced.

Change remote batteries.

Water-full indicator turns on.

Drain water out.

Machine  auto-restarts 
frequently

Direct sunlight

Draw the curtains

Door and windows are open, 

many heat sources in the room.

Close the door and windows, 

move out heat sources.

Filters are too dirty.

Clean or replace filters

Air-inlet or air-outlet is blocked

Remove blockage

Unit works for a short  
time only.

Bends or kinks in the air Exhaust Hose.

Position the hose properly, keeping it 
as short as possible with no bends.

Air outlet/inlet grilles are blocked.

Visual inspect the unit to make sure 
no foreign material is obstruction the 
airflow.

Unit does not cool the room.

Room size too large.

Unit is suitable for a room size of 
24m

2

 with a standard ceiling height 

of 2.4m.

Direct sunlight onto the unit.

Close curtains and pull down blinds.

Windows or doors open.

Close doors and windows.

Another heat source in the room.

Eliminate all other heat sources. 

Outlet duct venting the hot air properly.

Adjust the hose properly so that 
there is no back flow of hot air in  
the room.

Room temperature below your 
selected temperature.

Adjust the room temperature.

Unit is too noisy.

Unit placed on a hard surface  
causing it to vibrate.

A soft carpeted surface may absorb 
excessive vibration.

The unit does not operate  
for about three minutes after 
it is restarted.

This is for the safety of the compressor 
which prevents the unit from being 
restarted until three minutes have 
elapsed since it was last turned off.

This is part of normal operation.

If the machine will not be used for a long time.
1. 

Pull the drain cap out, drain the water in the water tray to another vessel that holds water.

2. 

Ensure the tilt angle of the unit shall not be greater than 30 degrees.

3. 

Start the unit, turn the mode to the low fan speed state of the air supply mode, keep this state for half a 

day and will dry the interior of the unit to prevent mold.

4. 

Turn off the unit, unplug the power plug, wrap the power cord, install the water plug and drain cap.

5. 

Remove the heat exhaust duct assembly and keep it properly.

6. 

Clean and dry filters, then reinstall them.

7. 

Pack the air-conditioner properly with soft plastic bag to protect from dust. Put the unit in a dry place, 

away from direct sunlight.

8. 

Keep the unit out of the reach of children.

9. 

Take out the batteries of the remote control and keep it properly. 

Note: Ensure that the unit is put in a dry place. All accessories of the unit should be stored  

in a secure place.

SEASON CLEANING

MAINTENANCE

• 

Please pull out plug before cleaning.

• 

Use soft semi-dry cloth to clean the machine. Don’t use chemical agents, such as benzene, alcohol, 

gasoline and so on. Otherwise the machine surface will be damaged, or even the machine itself.

• 

Don’t spatter water into the machine.

If the filter screen is clogged with 

dust, and the effectiveness of the air 

conditioning is reduced, be sure to clean 

the filter screen once every week of 

operation.
Clean the upper filter screen frame:
1. Detach the filter by holding the locking 

clip and pushing it outwards.

2. Once the filter assembly is taken out 

from the assembly.  Remove the filter 

frame place inside the assembly. 

Please apply minimum force during 

the process as the filter frame nets are 

delicate in design.

3. Use vacuum cleaner to remove the 

dust from the filter frame. If the frame 

is very dusty; place it in the warm 

water under 40°C or 104°F to which 

neutral detergent is added for cleaning 

and then dry them in the shade. Rinse 

the filter and dry it in a shaped place.

NOTE:  Don’t run the machine without 

filters. Do not damage the 

mesh fabric on the filter frame 

and filter mesh.

Prior to maintenance and servicing of the unit, turn off the power and unplug the plug to avoid  

electric shocks.

SURFACE CLEANING

CLEANING THE INTAKE GRILLES AND EVAP FILTER

Locking 

Clip

Locking 

Clip

Summary of Contents for PA1201GB

Page 1: ...ntinuous research and development the specifications herein are subject to change without notice Important Please read these instructions carefully GBIN004058 PORTABLE AIR CONDITIONER Instruction Manual PA1201GB ...

Page 2: ...ntenance or cleaning ALWAYS keep a clearance of at least 200mm from walls furniture and curtains Safety Precautions 2 Parts Description 4 Placement and Installation 4 Control Panel 6 Remote Control 6 Operation 6 Water Drainage 9 Maintenance 10 Trouble Shooting 11 Specifications 12 ELECTRICAL CONNECTIONS Before you plug the appliance into the mains socket check the following The appliance shall be ...

Page 3: ...nd the Unit when the hose is not connected Mounting in the Wall Correct Bending 1 The hose inlet is embedded at the back of the air conditioner 2 This air conditioner is required to have the exhaust hose fitted over the hose inlet Pull few threads of the exhaust hose 3 Fix the exhaust hose to the moulded threads on hose inlet by turning it in a counter clockwise direction The exhaust hose can be e...

Page 4: ...perating once the pre set time is elapsed To cancel the timer setting press the TIMER button again and push timer button continuously to count the timer back to 0 TIMER OFF Setting only when it is RUNNING This function is used to turn OFF the unit after a specific time interval To set the OFF time To turn off the operating unit after certain duration of time interval press the TIMER button on the ...

Page 5: ...tance follow the same procedure for dehumidifying GBIN004058 GBIN004058 PLUG WIRING SAFETY FEATURES FROST PROTECTION FUNCTION LOW TEMPERATURE The unit is fitted with a frost protection device to avoid excessive formation of ice during Cooling Dry or Sleep mode The unit will start automatically when defrosting process is completed OVERFLOW PROTECTION FUNCTION When water in the water pan exceeds the...

Page 6: ...to another vessel that holds water 2 Ensure the tilt angle of the unit shall not be greater than 30 degrees 3 Start the unit turn the mode to the low fan speed state of the air supply mode keep this state for half a day and will dry the interior of the unit to prevent mold 4 Turn off the unit unplug the power plug wrap the power cord install the water plug and drain cap 5 Remove the heat exhaust d...

Page 7: ...ated as continuing as if the repaired or replacement product was supplied at the original date of purchase Your statutory rights remain unaffected and nothing in this warranty shall limit or exclude our liability for any rights you have under the Consumer Rights Act 2015 If any part of this warranty is deemed unenforceable including any exclusion of liability the enforceability of any other parts ...