8
9
WATER DRAINAGE
This product has a self-evaporative system. The
condensing water will be recycled to cool the
condenser. This not only improves cooling efficiency,
but also saves energy.
But in case if the internal vessel fills up, then the
compressor will stop working and the corresponding
LED indicator light will light up next to “Water Full” icon
on the control panel. Refer to the below mentioned
steps for manual water drainage. Turn OFF the power
from the unit and remove the plug from the mains
socket. Following procedures below to remove water
condensation.
1. Unplug the unit from power source.
2. Place a shallow pan under the lower drain plug.
3. Remove the drain cap located on back side at the bottom of the unit.
4. Water will drain out and collect in the shallow pan.
5. After the water is drained, replace the lower drain plug firmly.
You can now turn on the unit. The machine will run normally.
NOTE:
• Keep the drainage cap and the water plug securely for later use.
• During drainage, the unit can be tilted slightly backwards to undergo the drainage process smoothly.
• If the water container cannot hold all the water, before the water container is full, insert the water outlet
with the water plug as soon as possible to prevent any spill of water on the carpet or floor area.
• When the water is discharged, insert the water plug, and tighten the drainage cover.
• If the water full alarm is often on, there may be some malfunction. Contact the service centre for
advice/ help/service. Alternatively, in extreme humidity in tropical zones, the unit may not be able
to evaporate the condensing water effectively, in this instance, follow the same procedure for
dehumidifying.
GBIN004058
GBIN004058
PLUG WIRING
SAFETY FEATURES
FROST PROTECTION FUNCTION (LOW TEMPERATURE)
The unit is fitted with a frost protection device to avoid excessive formation of ice during Cooling, Dry
or Sleep mode. The unit will start automatically when defrosting process is completed.
OVERFLOW PROTECTION FUNCTION
When water in the water pan exceeds the warning level, the machine will automatically sound an alarm,
and the “FULL” indicator light will flash. At this point, you need to move the drainage pipe connecting the
machine or the water outlet to a suitable drainage area to empty the water (For details, refer to the Drainage
Instructions section in the instructions). After the water is emptied, the machine will automatically return to
the original state.
PROTECTION FUNCTION OF THE COMPRESSOR
To increase the service life of the compressor, it has a 3-minute delay booting protection function
after the compressor is turned off.
Plug must also be fitted with a genuine BS1362 approved fuse with the
below rating which is dependent on the rated wattage of the product.
Fuse Rating
Rated Power
3A
Up to 700W
5A
Up to 1150W
13A
Up to 3000W
NOTE: The plug is incorporated with a 13Amp fuse.
F
U
S
E
BROWN
15
mm O ALL
6
mm BARE
BLUE
25
mm O ALL
6
mm BARE
45
mm O ALL
6
mm BARE
GREEN &
YELLOW
N
L
INSIDE
VIEW
O CORD.GRIP O
These safety instructions should be read
carefully and kept in safe place for future
reference.
The appliance is fitted with a plug
that complies with BS1363.
Wires colour code as below:
Brown
– Live
Blue
– Neutral
Yellow & Green – Earth
If the appliance is fitted with a 2-core cable
it is double insulated and will not have the
Earth (Yellow & Green) wire.
IT IS ESSENTIAL THAT THE WIRES ARE
ATTACHED ONLY TO THEIR DESIGNATED
POSITION IN THE PLUG AS SHOWN .
Drainage