SAFETY INSTRUCTIONS

• Keep the ice packs (supplied) away from the 

children as they contain chemical based 

crystals.

• DO NOT use this unit for functions other than 

those described in this instruction manual

• DO NOT tilt the unit. Always keep in upright. 

Position on a flat and stable surface, where 

it cannot be easily knocked over. Take extra 

care when operating 

• DO NOT cover or obstruct the air filter inlet or 

outlet grilles

• DO NOT use the unit in a wet room, such as a 

bathroom or laundry

• DO NOT sit or place articles on the unit
• DO NOT touch the unit with wet hands or bare 

feet

• DO NOT let chemical substances come into 

contact with the unit

• DO NOT use the unit in the presence of 

inflammable substances or vapour such as 

alcohol, insecticides, petrol etc.

• DO NOT use the mains plug to start and stop 

the unit

• DO NOT pull the supply cord or place it near 

a heat source. Always unwind the cord 

completely to avoid overheating. If the supply 

cord is damaged it must be replaced by the 

service agent or a similarly qualified person, 

in order to avoid a hazard

• DO NOT allow children to play with this 

appliance. This appliance is not intended 

for use by children or infirm persons without 

supervision.

• DO NOT conduct repairs on this unit. It has 

been built in accordance with relevant safety 

and performance standards. An electrical 

specialist must carry out all repairs.

• If the power cord is damaged, it must be 

replaced by a qualified electrician

• DO NOT use the unit without the filter fitted
• DO NOT allow objects to enter any ventilation 

or exhaust other than ice or water as 

specified in these instructions

• This unit is intended for indoor use only.
• ALWAYS unplug the unit from the mains before 

maintenance or cleaning

• ALWAYS use the switch on the control panel to 

start and stop the unit

• ALWAYS keep a clearance of at least 20cm 

from walls furniture and curtains

• ALWAYS turn off and unplug the unit when not 

in use

• ALWAYS switch off, and unplug the unit before 

filling up with water or ice

• Adequate clean water should be put into 

the water tank within the water level limits 

shown on the level indicator.

• Should you wish to move the unit any great 

distance, or before storing it, always drain the 

water from the tank using the plug provided at 

the bottom of the unit.

• When draining the water tank always do this 

over a bucket, outside so that water does not 

damage the carpet or flooring

ENERGY SAVING TIPS

• Use the unit in the recommended room size of 

up to 20m

2

 (assuming standard 2.4m ceiling 

height)

• Do not locate the air conditioner where 

furniture or other objects can obstruct the air 

flow.

• Keep blinds/curtains closed during the 

sunniest part of the day

• Close the fireplace damper, floor and/or wall 

registers, so cool air does not escape through 

the chimney or duct work

• Keep the air filter clean
• Set the unit to maximum cooling and high 

speed ventilation for the initial startup, then 

adjust the unit down to a more comfortable 

setting as required

AEC001 Instructions.indd   2

31/7/09   3:57:38 PM

Summary of Contents for AEC001

Page 1: ...development the specifications herein are subject to change without notice 11 Litre Portable Air Conditioner Instructions Manual AEC001 Important Please read these instructions carefully AEC001 Instructions indd 1 31 7 09 3 57 38 PM ...

Page 2: ...st be replaced by a qualified electrician DO NOT use the unit without the filter fitted DO NOT allow objects to enter any ventilation or exhaust other than ice or water as specified in these instructions This unit is intended for indoor use only ALWAYS unplug the unit from the mains before maintenance or cleaning ALWAYS use the switch on the control panel to start and stop the unit ALWAYS keep a c...

Page 3: ...high medium low 5 Mode Switch 6 Mode indicators Normal Breeze Circulate 7 Cool switch 8 Cool indicator 9 Oscillate switch 10 Oscillate indicator 11 Timer switch 12 Time indicators 0 5 Hr 1 Hr 2 Hr 4 Hr 13 Remote sensor window IDENTIFICATION 1 Control panel Air inlet filter 2 3 Cool air outlet 4 Horizontal louvers 5 Vertical louvers 6 Front body 7 Water level indicator Water entrance 8 9 Caster whe...

Page 4: ...ght It is recommended to set the fan speed at low under this mode for quieter performance and less energy consumption Please make sure sufficient water is in the storage tank before operation Refer to Storage Drainage section for details Cool Function Cool switch is used to operate the automated water conveyor system This function is recommended for higher efficient cooling effect under any mode O...

Page 5: ...bottom of the unit to ensure supply of cool air Before storing water in the unit switch the unit off and unplug from the mains supply Water is poured into the storage tank through the water entrance on the side of the unit as shown below to appropriate level from the water level indicator in the front of the unit Make sure that the water storage tank is re filled once it runs out To drain the wate...

Page 6: ...at the rear of the unit can be cleaned if required The foam filter should be cleaned in a mild soapy solution then left to dry before replacing External enclosure can be cleaned with a damp cloth Cleaning the Air Filter Unplug the power cord loosen the screw of the air filter to remove the air filter In a smoky or dusty environment the filter may appear gray after 1 2 months and will need to be cl...

Page 7: ...7 SPECIFICATIONS Input power consumption 65 watt AEC001 Instructions indd 7 31 7 09 3 57 40 PM ...

Page 8: ...rchaser wish to make a claim under the guarantee the product should be returned pre paid to the place of purchase To obtain warranty the purchase receipt must be returned with the product This guarantee is in addition to and does not take away from any rights available to the consumer under the Trade Practices Act and the State consumer protection legislation 24 month guarantee applies for domesti...

Reviews: