7
EN
7. After you have made sure that the appliance is
totally clean, let the descaling agent pour out of
the appliance through the drain plug on the left
side of the appliance.
8. Now pour clean water in the water reservoir and
repeat step 1 till 4 several times to make sure
that there are no scraps of the descaling agent
left in the appliance. The smell and taste of the
descaling agent should fully be disappeared.
Take every time new clean water for this.
9. The appliance is now ready for use again.
Note: Warranty is void if failure to de-scale regu-
larly leads to reduced functioning or failure of the
appliance.
Problem
Possible cause
Solution
“add water” or indicator
lights up.
Not enough water.
Switch off the appliance, fill up water
before switch on the appliance again.
“ice”or
indicator lights
up.
Too much ice in the appliance.
Remove the ice.
“add water” or and “ice”
or indicators flash.
Scoop is jammed.
Check whether the scoop is blocked
by ice. If not, contact your supplier.
Ice cubes melt together.
The cycle is too long.
Switch the appliance off and switch
back on when the ice cubes melt.
Select “Small” ice cubes.
Water temperature in the reservoir is
too low.
Change the water. The ideal water
temperature is 5°-15°C.
Appliance does not give an
error message, but does not
make any ice cubes.
Room temperature or water tempe-
rature is too high.
Put the appliance in a cooler place
and change the water.
Leak in the cooling system.
Contact your supplier.
Blockage in the cooling system.
Contact your supplier.
Technical specification
Item no.
271551
271568
Operating voltage and frequency
220-240V~ /50Hz
Rated input power
130W
120W
Rated current
1,1A
0,7A
Refrigerant used & injection
quantity
R290 / 33g
R600a / 29g
Climate class
SN-T
Foam blowing agent
Cyclopentane
Protection class
I
Material
Stainless steel
Net weight (approx.)
14,8kg
10,5kg
Dimension
380x435x(H)431mm
297x367x(H)378mm
Remark: Technical specification is subjected to change without prior notification.