![Arkon Agrimag Series User Manual Download Page 12](http://html.mh-extra.com/html/arkon/agrimag-series/agrimag-series_user-manual_2972755012.webp)
Agrimag User Guide
11
V1.9 26-4-2019
5. Outputs
5.1. AgrimagP
– Frequency output
Each AgrimagP is equipped with 0-1000Hz frequency output proportional to actual flow.
Standard open collector circuit.
Max switching voltage 24VDC, max current 50mA
A1
”: 211,765 pulses/lt
A2”:52,941 pulses/lt
A3”:20,455 pulses/lt
Colour coding:
Brown … +U
White …. GND
Green … OPE
Yellow
…. OPC
5.2. AgrimagP2
– Current loop output
Each AgrimagP2 is equipped with embeded 4-20mA current loop output signal module proportional to
actual flow.
Electrical Specifications:
12-bit DAC
Maximum Resolution
3.9 µA.
Output mode
Active or Passive
Colour coding:
Brown … +U
White …. GND
Green … A (RS485 communication bus)
Yellow
…. B (RS485 communication bus)
Gray …. I/O (4-20mA)
Blue …. –V (4-20mA)
Pink …. +V (4-20mA)