background image

AUSTRALIA

ArjoHuntleigh Pty Ltd
78, Forsyth street
O’Connor
AU-6163 Western Australia
Tel: +61 89337 4111
Free: +1 800 072 040
Fax: + 61 89337 9077 

BELGIQUE / BELGIË

ArjoHuntleigh NV/SA
Evenbroekveld 16
B-9420 ERPE-MERE
Tél/Tel: +32 (0) 53 60 73 80
Fax: +32  (0) 53 60 73 81
E-mail: [email protected]

 

CANADA

ArjoHuntleigh Canada Inc.
1575 South Gateway Road
Unit "C"
MISSISSAUGA, ON, L4W 5J1
Tel/Tél: +1 905 238 7880
Free: +1 800 665 4831 Institutional
Free: +1 800 868 0441 Home Care
Fax: +1 905 238 7881
E-mail: [email protected]

ESKÁ REPUBLIKA

ARJO Hospital Equipment s.r.o.
Hlinky 118
CZ- 603 00 BRNO
Tel: +420 549 254 252
Fax: +420 541 213 550

DANMARK

ArjoHuntleigh A/S
Vassingerödvej 52
DK-3540  LYNGE
Tel: +45 49 13 84 86
Fax: +45 49 13 84 87
E-mail: [email protected]

DEUTSCHLAND

ArjoHuntleigh GmbH
Peter-Sander-Strasse 10
D-55252 MAINZ-KASTEL
Tel: +49 (0) 6134 186 0
Fax: +49 (0) 6134 186 160
E-mail: [email protected]

C. Psimitis Co Ltd
Dimitriou Andr. 59
GR-16121 KAISARIANI ATTIKIS
:  21 0724 36 68
: 21 0721 55 53

ESPAÑA

ArjoHuntleigh Ibérica S.L.
Ctra. de Rubí, 88 1ª planta - A1
08173 Sant Cugat del Vallés
ES- BARCELONA 08173
Tel:  +34 93 583 11 20
Fax: +34 93 583 11 22
E-mail: [email protected]

FAR EAST 

ARJO Far East Limited
Unit 3A, 4/F., block B Hoi Luen 
Industrial Centre
55 Hoi Yuen Road, 
Kwun Tong, Kowloon
HONG KONG
Tel: +852 2508 9553
Fax: +852 2508 1416

FRANCE 

ArjoHuntleigh SAS
2 Avenue Alcide de Gasperi
BP 133
59436 RONCQ CEDEX
Tél: +33 (0) 3 20 28 13 13
Fax: +33 (0) 3 20 28 13 14
E-mail : [email protected]

INTERNATIONAL

ArjoHuntleigh International Ltd.
310-312, Dallow Road
Luton
UK-BEDFORDSHIRE LU1 1TD
Tel: +44 1582 745800
Fax: +44 1582 745866
E-mail:
[email protected]

ITALIA

ArjoHuntleigh S.p.A.
Via di Tor Vergata 432
00133 ROMA - ITALIA
Tel: +39 (0) 6 87426211
Fax: +39 (0) 6 87426222
E-mail: [email protected]

NEDERLAND

ArjoHuntleigh Nederland BV
Biezenwei 21
4004 MB TIEL
Postbus 6116
4000 HC TIEL
Tel: +31 (0) 344 64 08 00
Fax: +31 (0) 344 64 08 85
E-mail: [email protected]

NORGE

ArjoHuntleigh Norway AS
Ryenstubben 2
NO-0679 OSLO
Tel: +47 22 08 00 50
Faks: +47 22 08 00 51
E-mail: [email protected]

POLSKA

ArjoHuntleigh Polska Sp. z o.o.
ul. Ks Piotra Wawrzyniaka 2 
PL 62-052 KOMORNIKI (Poznan)
Tel: +48 61 662 15 50
Fax: +48 61 662 15 90
E-mail: [email protected]

PORTUGAL

ArjoHuntleigh em Portugal:
MAQUET Portugal, Lda. (Distribudor Exclusivo)
Rua Poeta Bocage n.º 2 - 2G  
1600-233 Lisboa, Portugal
Tel: +351 214 189 815
Fax: +351 214 177 413
E-mail: [email protected]

SUISSE / SCHWEIZ

ArjoHuntleigh AG
Florenzstrasse 1d
Postfach
CH-BASEL4023 
Tél/Tel: +41 (0) 61 337 97 77
Fax: +41 (0) 61 311 97 42

SUOMI

ArjoHuntleigh OY 
Vanha Porvoontie 229
FI-01380 VANTAA
Puh: +358 9 4730 4320
Faksi: +358 9 4730 4999

SVERIGE

ARJO  Scandinavia  AB
Verkstadsvägen 5
Box 61
SE-241 21 ESLÖV
Tel: +46 (0) 413 645 00
Fax: +46 (0) 413 645 83
E-mail: [email protected]

UNITED KINGDOM

ArjoHuntleigh International Ltd.
310-312, Dallow Road
Luton
UK-BEDFORDSHIRE LU1 1TD
Tel: +44 1582 745700
Fax: +44 1582 459100
E-mail:
[email protected]

USA

ArjoHuntleigh Inc.
2349 W Lake Street Suite 250
Addison, IL 60101
Tel: +1 630 307 2756
Free: +1 800 323 1245 Institutional
Free: +1 800 868 0441 Home Care
Fax: +1 630 307 6195
E-mail: [email protected]

ÖSTERREICH

ArjoHuntleigh GmbH
Dörrstrasse 85
AT-6020 INNSBRUCK
Tel: +43 (0) 512 204 160 0
Fax: +43 (0) 512 204 160 75

www.arjohuntleigh.com

Summary of Contents for STEDY

Page 1: ... with people in mind STEDY Instructions for Use NTX01400 US rev 10 July 2011 ...

Page 2: ...formation is available by contacting ArjoHuntleigh Our policy is one of continous development and we therefore reserve the right to make technical alterations without notice The content of this publication may not be copied either whole or in part without the consent of BHM Medical Inc ...

Page 3: ...bols 3 Part Designation 4 Safety Instructions 5 General 5 Equipment warning labels 5 Care of the Stedy 6 Care checkpoints 6 Servicing advice 7 Operating the Stedy 8 General 8 At the toilet 9 Using the back support strap 10 Parts List General Exploded View 12 Parts list general parts list 13 Preventive Maintenance Schedule 14 Technical Specifications 16 ...

Page 4: ...y Street Magog Quebec Canada J1X 5Y5 Authorized European Representative Huntleigh Healthcare Ltd 310 312 Dallow Road Luton UK LU1 1TD Distributor information A complete listing is available on the last page of this manual Service and support A service routine has to be performed on the Stedy by ArjoHuntleigh trained personnel to ensure the safety and operation of your product See Preventive Mainte...

Page 5: ...Maintenance Instructions All references to the patient in these instructions refer to the user or person being transported and reference to the attendant refers to the caregiver or the person who operates the Stedy WARNING Read before use Before using the Stedy you must read and fully understand these Operating Product Care and Maintenance Instructions You must be trained on the Stedy and on any a...

Page 6: ...ing Product Care and Maintenance Instructions This symbol indicates the products comply with all the applicable European Directives This symbol is accompanied by the manufacturer s serial number This symbol indicates separate collection for all batteries and accumulators as per the WEEE Directive This symbol is accompanied by the name and by the address of the authorized representative in the Euro...

Page 7: ...s D Padded kneepad E Footboard F Castor brake G Support strap attachment lugs H Back support strap optional extra I Attachment clips J Waist strap K Buckle L Fleece cover if fitted LEGEND Part Designation A G B C F E J K L H I D Optional back support strap ...

Page 8: ... move the Stedy Do not attempt to push or pull a loaded lift over a floor obstruction which the castors are unable to ride over easily including steps door thresholds or moving side walks Do not push the lift at a speed which exceeds a slow walking pace 3 km hour or 0 8 meter second An assessment of the suitability for transfer of a resident patient who is connected to electrodes catheters or othe...

Page 9: ...C 165 F Do not use petroleum based solvents or similar since this may damage plastic parts For disinfection of contaminated equipment and accessories use the preferred method of wiping the product completely with hard surface disin fectant wipes that are supplied impregnated with a 70 v v solution of Isopropyl Alcohol Note A rubbing action will be necessary when using the wipes to promote effectiv...

Page 10: ...nt The simplest safest and most effective way to maintain your product in good working order is to have it methodically and professionally serviced at least annually by an ArjoHuntleigh approved engineer using ArjoHuntleigh approved spare parts For information on service and maintenance contracts please contact your local ArjoHuntleigh representative Care of the Stedy ...

Page 11: ...ted resident patient from the front see Fig 1 Carefully position the Stedy close enough to the resident patient to enable his her feet to be placed on the footboard with his her knees comfortably against the padded kneepad see fig 2 WARNING Ensure there is sufficient space underneath and to the sides of the resident patient s chair bed etc to achieve full entry with the Stedy Fig 1 Apply the casto...

Page 12: ...ee fig 6 If the resident patient has difficulty supporting herself himself make her him hold firmly onto the crossbar The resident patient will be kept in position by her his knees being in contact with the kneepad At the Toilet The resident patient and Stedy can be reversed over the toilet Once in position apply the caster brakes and encourage the resident patient to stand remove the resident pat...

Page 13: ...ith the patient s arms outside the strap see fig 7 Fig 7 If needed the additional waist strap attached to the back support strap can be fitted around the resident patient for a feeling of extra stability To use the additional waist strap ensure the strap is separated at the buckle then position it loosely around the body ensuring it is not twisted or trapped behind the resident patient s back see ...

Page 14: ...ap is fitted in position see fig 10 When using the support strap the resident patient should still be encouraged to hold onto the crossbar see fig 11 Fig 10 Fig 11 WARNING Always check that one support strap attachment clip on each side is in position before and during transportation Operating the Stedy ...

Page 15: ...12 Parts List General Exploded View 1 2 3 4 5 6 7 8 9 10 11 12 13 12 6 15 16 14 ...

Page 16: ...16 not illustrated Stedy Spare Parts Kits PART NUMBER QTY DESCRIPTION NTX01400 US 1 Operating and Product Care Instructions NTS0001 20 1 Side frame L H side spares kit includes 1 6x2 7x2 9 10x2 11x2 14x2 16 17 18 NTS0002 20 1 Side frame R H side spares kit includes 1 4 6x2 7x2 10x2 11x2 14x2 17 18 NTS0003 20 1 Kneepad spares kit includes 1x2 7x4 8 17 18 NTS0004 1 Footboard spares kit includes 5 6x...

Page 17: ...contamination regulations X FREQUENCY Before every use Weekly Every12 months ArjoHuntleigh STEDY Carry out a visual inspection of all external parts All functions must be tested for correct operation to ensure no adverse damage has occurred during previous use X Where necessary after each patient use carry out decontamination of the ArjoHuntleigh Stedy in accordance with ArjoHuntleigh Operating Pr...

Page 18: ... sure the casters are firmly secured to the chassis X Make sure all instruction labels are firmly attached and in good readable condition Replace when necessary X Inspect the two sling attachment points If worn or damaged replace with new X FREQUENCY Before every use Weekly Every12 months Preventive Maintenance Schedule ...

Page 19: ... 8 kg 37 lb Maximum permitted loading 120 kg 264 lb Dimensions in millimeters equivalent in inches 31 1 1 4 133 5 1 4 614 24 3 16 523 20 9 16 455 17 15 16 865 34 1 16 788 31 990 39 591 23 1 4 830 32 11 16 470 18 1 2 775 30 1 2 1050 41 3 8 ...

Page 20: ...UK BEDFORDSHIRE LU1 1TD Tel 44 1582 745800 Fax 44 1582 745866 E mail international arjohuntleigh com ITALIA ArjoHuntleigh S p A Via di Tor Vergata 432 00133 ROMA ITALIA Tel 39 0 6 87426211 Fax 39 0 6 87426222 E mail Italy promo arjohuntleigh com NEDERLAND ArjoHuntleigh Nederland BV Biezenwei 21 4004 MB TIEL Postbus 6116 4000 HC TIEL Tel 31 0 344 64 08 00 Fax 31 0 344 64 08 85 E mail info nl arjohu...

Page 21: ...ns for infection control within healthcare and contamination prevention within life sciences MAQUET specializes in solutions therapies and products for surgical interventions and intensive care and are trademarks belonging to the ArjoHuntleigh group of companies ª EDICALª NC ª As our policy is one of continuous development we reserve the right to modify designs and specifications without prior noti...