background image

16

Technical Specifications

Weight..........................................................16.8 kg (37 lb)
Maximum permitted loading.......................120 kg (264 lb)

Dimensions in millimeters, equivalent in inches.

31 (1

 1

/

4

”)

133 (5

 1

/

4

”)

61

4 (24

 

3

/

16

”)

523 (20

 9

/

16

”)

455 (17 

15

/

16

”)

865 (34

 1

/

16

”)

788 (31”)

9

90 (39

”)

591 (23 

1

/

4

”)

83

0 (32

 

11

/

16

”)

4

70 (1

1

/

2

”)

775 (30 

1

/

2

”)

105

0 (41

 

3

/

8

”)

Summary of Contents for STEDY

Page 1: ... with people in mind STEDY Instructions for Use NTX01400 US rev 10 July 2011 ...

Page 2: ...formation is available by contacting ArjoHuntleigh Our policy is one of continous development and we therefore reserve the right to make technical alterations without notice The content of this publication may not be copied either whole or in part without the consent of BHM Medical Inc ...

Page 3: ...bols 3 Part Designation 4 Safety Instructions 5 General 5 Equipment warning labels 5 Care of the Stedy 6 Care checkpoints 6 Servicing advice 7 Operating the Stedy 8 General 8 At the toilet 9 Using the back support strap 10 Parts List General Exploded View 12 Parts list general parts list 13 Preventive Maintenance Schedule 14 Technical Specifications 16 ...

Page 4: ...y Street Magog Quebec Canada J1X 5Y5 Authorized European Representative Huntleigh Healthcare Ltd 310 312 Dallow Road Luton UK LU1 1TD Distributor information A complete listing is available on the last page of this manual Service and support A service routine has to be performed on the Stedy by ArjoHuntleigh trained personnel to ensure the safety and operation of your product See Preventive Mainte...

Page 5: ...Maintenance Instructions All references to the patient in these instructions refer to the user or person being transported and reference to the attendant refers to the caregiver or the person who operates the Stedy WARNING Read before use Before using the Stedy you must read and fully understand these Operating Product Care and Maintenance Instructions You must be trained on the Stedy and on any a...

Page 6: ...ing Product Care and Maintenance Instructions This symbol indicates the products comply with all the applicable European Directives This symbol is accompanied by the manufacturer s serial number This symbol indicates separate collection for all batteries and accumulators as per the WEEE Directive This symbol is accompanied by the name and by the address of the authorized representative in the Euro...

Page 7: ...s D Padded kneepad E Footboard F Castor brake G Support strap attachment lugs H Back support strap optional extra I Attachment clips J Waist strap K Buckle L Fleece cover if fitted LEGEND Part Designation A G B C F E J K L H I D Optional back support strap ...

Page 8: ... move the Stedy Do not attempt to push or pull a loaded lift over a floor obstruction which the castors are unable to ride over easily including steps door thresholds or moving side walks Do not push the lift at a speed which exceeds a slow walking pace 3 km hour or 0 8 meter second An assessment of the suitability for transfer of a resident patient who is connected to electrodes catheters or othe...

Page 9: ...C 165 F Do not use petroleum based solvents or similar since this may damage plastic parts For disinfection of contaminated equipment and accessories use the preferred method of wiping the product completely with hard surface disin fectant wipes that are supplied impregnated with a 70 v v solution of Isopropyl Alcohol Note A rubbing action will be necessary when using the wipes to promote effectiv...

Page 10: ...nt The simplest safest and most effective way to maintain your product in good working order is to have it methodically and professionally serviced at least annually by an ArjoHuntleigh approved engineer using ArjoHuntleigh approved spare parts For information on service and maintenance contracts please contact your local ArjoHuntleigh representative Care of the Stedy ...

Page 11: ...ted resident patient from the front see Fig 1 Carefully position the Stedy close enough to the resident patient to enable his her feet to be placed on the footboard with his her knees comfortably against the padded kneepad see fig 2 WARNING Ensure there is sufficient space underneath and to the sides of the resident patient s chair bed etc to achieve full entry with the Stedy Fig 1 Apply the casto...

Page 12: ...ee fig 6 If the resident patient has difficulty supporting herself himself make her him hold firmly onto the crossbar The resident patient will be kept in position by her his knees being in contact with the kneepad At the Toilet The resident patient and Stedy can be reversed over the toilet Once in position apply the caster brakes and encourage the resident patient to stand remove the resident pat...

Page 13: ...ith the patient s arms outside the strap see fig 7 Fig 7 If needed the additional waist strap attached to the back support strap can be fitted around the resident patient for a feeling of extra stability To use the additional waist strap ensure the strap is separated at the buckle then position it loosely around the body ensuring it is not twisted or trapped behind the resident patient s back see ...

Page 14: ...ap is fitted in position see fig 10 When using the support strap the resident patient should still be encouraged to hold onto the crossbar see fig 11 Fig 10 Fig 11 WARNING Always check that one support strap attachment clip on each side is in position before and during transportation Operating the Stedy ...

Page 15: ...12 Parts List General Exploded View 1 2 3 4 5 6 7 8 9 10 11 12 13 12 6 15 16 14 ...

Page 16: ...16 not illustrated Stedy Spare Parts Kits PART NUMBER QTY DESCRIPTION NTX01400 US 1 Operating and Product Care Instructions NTS0001 20 1 Side frame L H side spares kit includes 1 6x2 7x2 9 10x2 11x2 14x2 16 17 18 NTS0002 20 1 Side frame R H side spares kit includes 1 4 6x2 7x2 10x2 11x2 14x2 17 18 NTS0003 20 1 Kneepad spares kit includes 1x2 7x4 8 17 18 NTS0004 1 Footboard spares kit includes 5 6x...

Page 17: ...contamination regulations X FREQUENCY Before every use Weekly Every12 months ArjoHuntleigh STEDY Carry out a visual inspection of all external parts All functions must be tested for correct operation to ensure no adverse damage has occurred during previous use X Where necessary after each patient use carry out decontamination of the ArjoHuntleigh Stedy in accordance with ArjoHuntleigh Operating Pr...

Page 18: ... sure the casters are firmly secured to the chassis X Make sure all instruction labels are firmly attached and in good readable condition Replace when necessary X Inspect the two sling attachment points If worn or damaged replace with new X FREQUENCY Before every use Weekly Every12 months Preventive Maintenance Schedule ...

Page 19: ... 8 kg 37 lb Maximum permitted loading 120 kg 264 lb Dimensions in millimeters equivalent in inches 31 1 1 4 133 5 1 4 614 24 3 16 523 20 9 16 455 17 15 16 865 34 1 16 788 31 990 39 591 23 1 4 830 32 11 16 470 18 1 2 775 30 1 2 1050 41 3 8 ...

Page 20: ...UK BEDFORDSHIRE LU1 1TD Tel 44 1582 745800 Fax 44 1582 745866 E mail international arjohuntleigh com ITALIA ArjoHuntleigh S p A Via di Tor Vergata 432 00133 ROMA ITALIA Tel 39 0 6 87426211 Fax 39 0 6 87426222 E mail Italy promo arjohuntleigh com NEDERLAND ArjoHuntleigh Nederland BV Biezenwei 21 4004 MB TIEL Postbus 6116 4000 HC TIEL Tel 31 0 344 64 08 00 Fax 31 0 344 64 08 85 E mail info nl arjohu...

Page 21: ...ns for infection control within healthcare and contamination prevention within life sciences MAQUET specializes in solutions therapies and products for surgical interventions and intensive care and are trademarks belonging to the ArjoHuntleigh group of companies ª EDICALª NC ª As our policy is one of continuous development we reserve the right to modify designs and specifications without prior noti...

Reviews: