                                                                           16                                       AH-SO-03     08/10/2017 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Handle with care.  Do not drop.  Avoid shock or violent impact. 

  

The equipment should be stored in a clean dry and well ventilated area.  The following 

limits apply during transport and for a storage period of up to 15 weeks.: 

  

 

Ambient temperature: 

  -25°C                to             +70°C 

 

Relative humidity:   

   10%  

      to             75% 

 

Air pressure:  

 

50k Pa 

      to             106kPa 

  

The following limits apply to operating conditions on longer periods of storage: 

  

 

Ambient temperature: 

+10°C      

      to   

 +40°C 

 

Relative humidity:   

   30%  

      to      

 75% 

 

Air pressure:  

 

70k Pa 

      to   

106kPa 

Storage for beds with battery back up 
  

When storing the bed, or when the bed is not in use for long periods of time it is 

recommended that the beds battery power capacity is topped up periodically following 

the guidelines set out below. 

  

Storage Temperature 

 

 

 

 

 

Charging Interval 

  

20°C or less   

 

 

 

Charge batteries for 24 hours every 9 months 

  

20-30°C 

 

 

 

 

Charge batteries for 24 hours every 6 months 

  

30-40°C 

 

 

 

 

Charge batteries for 24 hours every 3 months 

10. Transportation and Storage 

Summary of Contents for Sorrento

Page 1: ...1 AH SO 03 08 10 2017 SORRENTO USER MANUAL ...

Page 2: ...e electrically powered beds in the presence of flammable gases such as anesthetics agents Do not use electrically powered beds in operating theatres Warnings Cautions Notes Warnings given in this manual identify possible hazards in procedures or conditions which if not correctly followed could result in death injury or other serious adverse reactions Cautions given in this manual identify possible...

Page 3: ...erated profiling mattress platform with independent adjustment of backrest angle thigh section angle and calf section angle Height adjustment Manually operated calf elevation Integral mattress platform extension Detachable 3 4 length folding safety sides Steel sheet mattress support surface 100mm or 125mm individual locking castors 125mm or 150mm castors with central operation for braking and stee...

Page 4: ...safe working load of the bed is 200kg 3 Installation Connect the electrical power cable to a suitable socket outlet Wrap the electrical cable around the cable retainer only when the bed is in transportation The cable retainer is located at the head end of the bed WARNING Make sure that handsets and electrical power cables cannot become entangled with moving parts of the bed Disconnect the electric...

Page 5: ...ree position they operate all brake castors simultaneously When the linked pedals are raised from the horizontal free position they engage one head end castor so that it cannot swivel Push the bed in the direction of travel so that the castors are all in line and trailing then lift either pedal to engage the steering castor For easy access of brake steer pedals it is imperative to apply brakes bef...

Page 6: ...ion simply lift the top rail until the operating knob automatically clicks into its locked position at maximum height The Safety Side release mechanism contains a yellow band 1 When the operating knob is viewed from above if the yellow band can be seen it is an indication that the Safety Side is NOT securely locked in the upright position The yellow band should NEVER be visible from above when the...

Page 7: ...nd should be returned back to its upright position thereafter WARNING Fold Down Foot Panel Safe Working Load is 20kg To fold down pull up Panel to release and slowing lower down to a horizontal position To raise slowly lift Panel to a vertical position ensuring it is securely locked once upright Pull up to release Fold down Panel Adjusting the calf angle Holding the mattress retainer located on th...

Page 8: ...es both backrest and leg elevation simultaneously WARNING Some functions may cause injury to the patient if unintentional movement occurs WARNING If the Handset is dropped to the floor caught between bed parts or sustains any damage or suspected damage in any way immediately stop using the Handset and perform the full Handset Checks as detailed in Section 6 Maintenance Handset Handset is accessibl...

Page 9: ...r operation for short periods of time To ensure the batteries are kept fully charged the bed must be connected to the mains power supply at all times during normal use Patient Transfer If the patient is to be transferred by means of a patient hoist the bed will need to be raised enough to allow hoist access underneath the bed WARNING Bed functions particularly Hi Lo are not to be used during patie...

Page 10: ...ic cleaning solutions 6 Maintenance Troubleshooting The following preventative maintenance procedures should be carried out at intervals of 12 months or as specified All service or repair activities must only be performed by properly qualified and train persons who are approved by ArjoHuntleigh Disposal of product and components should be compliant with local regulations Warning Disconnect the bed...

Page 11: ...only If a beeping sound is heard when operating the bed it means that the battery is at low charge Re connect the bed to a mains power supply for a minimum of 24 hours so that the batteries can recharge Check the battery condition every six months using the following procedure Make sure that the bed has been connected to the mains power supply for an uninterrupted 24 hour period 1 Disconnect the b...

Page 12: ...sm and striker plate should be inspected every three months Check for rust structural integrity of welds and paint finish every twelve months HANDSET Checks Between each patient ArjoHuntleigh strongly advises that the Handset is visually inspected for obvious damage before each use if practicable and that Preventative maintenance checks are conducted on the handset When using a specific function s...

Page 13: ...bed Any handsets are found with obvious damage to the cable insulation immediately report the damage to maintenance staff or replace the Handset 3 Tactile inspection of the buttons All buttons should be operated and response tested Depress each button on the handset Each button should have a positive audible click that is also felt The function being pressed should also operate If the button Does ...

Page 14: ...ress 1980 x 880 x 170mm PM1 Clamp on length folding safety rails UNI FSR IV Pole Straight 93011755 Self help pole with handle SHP SS38 Troubleshooting The following table identifies some fault symptoms their possible cause and suggests some simple checks and corrective actions If these actions fail to solve the problem consult the ArjoHuntleigh Service Department on Freecall 1800 072 040 7 Accesso...

Page 15: ...1010 x 150 170mm King Single 2070 x 880 x 150 170mm Four Seasons range 2070 x 1010 x 150 170mm Four Seasons KS range Product weight approx Without safety sides 110kg 116kg King Single With safety sides 128kg 134kg King Single Safe Working Load 200kg Electrical Data 230V Power in 2 Amp Max at 230V 50Hz Duty Rating Intermittent 10 Max 2min 18min Electrical Safety Standards Complies with EN60601 1 UL...

Page 16: ...n longer periods of storage Ambient temperature 10 C to 40 C Relative humidity 30 to 75 Air pressure 70k Pa to 106kPa Storage for beds with battery back up When storing the bed or when the bed is not in use for long periods of time it is recommended that the beds battery power capacity is topped up periodically following the guidelines set out below Storage Temperature Charging Interval 20 C or le...

Page 17: ...ISBANE As our policy is one of continuous improvement we reserve the right to modify designs without prior notice ArjoHuntleigh ABN 75 007 200 900 A member of the Huntleigh Technology PLC Group of Companies Acare Medical Science Co Ltd No 6 Hongxingyi Road Hongwan Industrial Park Zhuhai Guangdong P R China 519060 TEL 86 756 6326076 FAX 86 756 6326103 ...

Reviews: