background image

7

A float switch installed at the water tank avoids an 

overfilling of the tank by turning on the pump and 

emptying the tank in case of level exceeding.

How to Use

Pour the waste into the bowl.
Flush the residue of the waste by pushing the hand 

button on the front of the unit or, if fitted, the knee-

actuated button.
The flush will stop automatically.
The 

Slop Hopper 

is designed to flush away liquids and 

suspensions of solids into the sewer system. The type 

and amount of liquids/suspensions that can be flushed is 

to be determined by sewer waste regulations in 

accordance with current local regulations and rules.

 

 

The 

Slop Hopper

 should not be used for the disposal of 

needles and syringes, human tissues or blood, human 

infections and pathological wastes (i.e. biopsy waste, 

diseased organs).

Cleaning

The 

Slop Hopper

 should be cleaned and disinfected 

regularly by 

Arjo

 trained personnel. Most commercially 

available cleaning products can be used except chlorine 

based products.

Caution

Never use products containing chlorine, abrasives or steel wool for
the cleaning since such products will lead to corrosion marks and
scratches on the stainless steel.

Do not spray the appliance with water.

Summary of Contents for AGSP

Page 1: ...Slop Hopper AGSP 5035886TM_04 02 2020 INSTALLATION OPERATING INSTRUCTIONS ...

Page 2: ...ging to the Arjo group of companies Arjo 2020 As our policy is one of continuous improvement we reserve the right to modify designs without prior notice The content of this publication may not be copied either whole or in part without the consent of Arjo ...

Page 3: ...6 About this Manual 6 Intended Use 6 How to Use 7 Cleaning 7 Components 8 Installation and Setup 9 Unpacking 9 Installation 9 Maintenance 11 Servicing 11 Cleaning the Water Filter 11 Cleaning the Drainage Tubing 11 Care 12 Trouble Shooting 13 Technical Description 14 Symbols 14 Spare Parts 15 ...

Page 4: ...g on this equipment Documents which state the names of the personnel who took part in and understood the training must be archived Never use the machine if you are not sure how to operate it The machine must be kept clean if it is to work properly The electric power must be switched off before the machine cabinet is opened The machine cabinet contains electrical components Always use the equipment...

Page 5: ...if necessary Isolator Switch The machine must be fitted with a separate isolating device in the electric power supply The isolating device must be easily accessible on a wall close to the machine The external electrical isolator switch must be marked I and O to identify the position of the switch Environmental Protection Incorrect disposal of this equipment and its component parts particularly bat...

Page 6: ...les office listed at the end of this manual Intended Use The Slop Hopper is designed to flush away liquids and suspensions of solids into the sewer system using an integrated booster pump This process is activated by a hand actuated or optionally by a knee actuated button installed in the front area of the Slop Hopper The pump is turned on by the integrated control system and conveys the water fro...

Page 7: ...hat can be flushed is to be determined by sewer waste regulations in accordance with current local regulations and rules The Slop Hopper should not be used for the disposal of needles and syringes human tissues or blood human infections and pathological wastes i e biopsy waste diseased organs Cleaning The Slop Hopper should be cleaned and disinfected regularly by Arjo trained personnel Most commer...

Page 8: ...ntilation openings in the base frame must not be obstructed Conductor Sieve insert Plate type Connection rim flushing Drainage tubing Control unit with cable set Water tank Flexible hose Rim rinsing connection piece Pump Hand button Label attention high tension Label rim flushing ...

Page 9: ...orbent and easy to clean 5 Apply a silicone bead around the outer edge and floor of the Slop Hopper 6 Connect the water supplies The connections must satisfy the requirements for water connection in accordance with the table below The pipes must be fitted with an approved shutoff valve Seal all connections with PTFE tape 7 Carry out the electrical installation as follows Install the Slop Hopper in...

Page 10: ...sified for at least 90 C 8 Perform the following function check on the Slop Hopper after installation Check that the Slop Hopper is connected to the correct supply voltage and that it is protected by a fuse of the correct rating as shown on the type plate Check that the temperature of the incoming mains water is correct The temperature must be in the range 3 25 C Check that there are no water leak...

Page 11: ...the aid of pliers Clean and check the filter Replace the filter if necessary Replacement is the reverse of the above procedure Cleaning the Drainage Tubing If the drainage tubing is blocked check and clean the drainage of the Slop Hopper If this has not cleared the blockage the drainage pipe has to be dismounted and cleaned as follows Turn off the water supply by using the upstream arranged shutof...

Page 12: ...arly For removing spots use commercially available cleaning products for chrome steel Clamp Siphon trap Caution Never use products containing chlorine abrasives or steel wool for the cleaning since such products will lead to corrosion marks and scratches on the stainless steel Do not spray the appliance with water ...

Page 13: ... fill up Water filter clogged Clean and or exchange filter Pump conveys water automatically in intervals or continuously Floating valve does not close correctly Control system defective At first turn off water supply then switch off the power supply Contact your local Arjo aftersales service office Water leak from the appliance Drainage or water supply pipe connections and couplings not tighten Tu...

Page 14: ...ely 8 0 litres 14pts adjustable between 3 9 litres Size 600mm H x 450mm W x 570mm D 24in H x 18in W x 22in D Weight approximately 25kg 55lb SYMBOLS Conformity Mark Do not dispose of in domestic refuse Manufacturer This symbol is accompanied by the name and the address of the manufacturer Dangerous voltage Rim flushing ENVIRONMENTAL INFORMATION Room Temperature 5 C to 40 C 41o F to 104o F Air Humid...

Page 15: ...without Rim Flush 2 1 463051000 Front Panel Flat design with Rim Flush 2 1 2 463051001 Front Panel Flat design without Rim Flush 3 1 4510008 Funnel shaped Slop Hopper Basin Stainless 4 4 SPL1019 Speed Nuts 4 1 4 602606 Countersink screw 5 1 602607 Blind Rivet Nut only with for Rim Flush 6 2 AH1021268 Front Panel Screw 7 4 499693900 Plastic Cap 8 2 AH1033176 Connecting screws set ...

Page 16: ... 4670302 Pump connection piece 4 1 4540076 Hand button 5 1 N A Label rim flushing 6 1 N A Plate model 7 1 4550503 Flexible hose 8 1 4670301 Tank 9 1 4670300 Connection rim flushing 10 1 4670299 Drainage tubing 10 1 1 4670299 1 Drainage tubing floor version 11 1 4670298 Slop Hopper Grate 12 1 4640089 Sieve insert 13 1 4540074 Control unit with cable set ...

Page 17: ...17 Table 3 Pump 2 3 1 4 5 Item Qty Part No Description 1 1 4630515 Pump bracket 2 1 4630516 Pump casing 3 1 4530104 Booster pump 4 3 602618 Anti vibration damper 5 3 600201 Locking nut ...

Page 18: ... Cable bushing 4 3 1 2 5 Item Qty Part No Description 1 1 AH1026695 Control unit 2 1 503607100 Conductor plate 3 1 4540077 Contact block 4 1 4540029 Floating switch horizontal 5 1 N A Label Attention high voltage ...

Page 19: ...19 Table 5 Control unit Qty Part No Description 1 4540074 Control unit with cable set ...

Page 20: ...No Description 1 4540076 Hand button 1 2 6 7 4 3 5 Item Qty Part No Description 1 1 4550051 Tank 2 1 4530112 Floating Valve 3 1 4550057 Elbow hose 4 1 4560079 Outlet bend with sealing 5 2 602622 Hose clamp 6 1 600401 Hexagon bolt 7 1 600204 Washer ...

Page 21: ...21 Table 8 Floating valve 1 2 3 Item Qty Part No Description 1 1 4530112 Floating valve 2 1 N A Flow limiter 3 1 N A Mudguard ...

Page 22: ...22 Table 9 Pump connection piece 2 3 2 1 4 Item Qty Part No Description 1 1 4560067 Quick release coupling 2 2 602622 Pipe clamp 3 1 4550505 Hose with cloth 4 1 N A Sealing ...

Page 23: ...10 Connection rim flushing 1 5 4 3 2 Item Qty Part No Description 1 1 4560066 Quick release coupling 2 1 4560048 Elbow union with sealing 3 1 4560149 Pipe union 4 1 4550504 Hose with cloth 5 2 602615 Hose clamp ...

Page 24: ... Part No Description 1 1 4640030 Drainage Tubing for Slop Hopper 1 1 1 4640031 Drainage Tubing for Slop Hopper floor version 2 1 4550046 Rapid Binder Normaconnect 3 1 4640102 Stainless Steel Pipe 1 2 Item Qty Part No Description 1 2 4520016 Grate 2 4 600199 Collar caps ...

Page 25: ...25 Table 13 Sieve insert Item Qty Part No Description 1 1 4640089 Sieve insert ...

Page 26: ...26 Table 14 Cover for Slop Hopper with hinges Item Qty Part No Description 1 1 89110040 Cover for Slop Hopper with hinges ...

Page 27: ...omo arjo com MIDDLE EAST Arjo Middle East FZ LLC Of ce 908 9th Floor HQ Building North Tower Dubai Science Park Al Barsha South P O Box 11488 Dubai United Arab Emirates Direct 971 487 48053 Fax 971 487 48072 Email Info ME arjo com NEDERLAND Arjo BV Biezenwei 21 4004 MB TIEL Postbus 6116 4000 HC TIEL Tel 31 0 344 64 08 00 Fax 31 0 344 64 08 85 E mail info nl arjo com NEW ZEALAND Arjo Ltd 34 Vestey ...

Page 28: ...ure ergonomic patient handling personal hygiene disinfection diagnostics and the effective prevention of pressure ulcers and venous thromboembolism we help professionals across care environments to continually raise WKH VWDQGDUG RI VDIH DQG GLJQL HG FDUH YHU WKLQJ ZH GR ZH GR ZLWK SHRSOH LQ PLQG ArjoHuntleigh AB Hans Michelsensgatan 10 211 20 Malmö Sweden www arjo com ...

Reviews: