1.2 Components
The top (1) lies loose on top of the stove, with two guide lugs or is locked with quick
release locks. The top is lifted to access the cleaning hatch (2). When there is a hatch it
is opened by removing the four screws, one can then sweep the flue (3) and the smoke
tubes (4).
The flue can easily be turned through 90˚, which makes it possible to connect it to the
chimney vertically or horizontally.
The front (5) can be opened. This is how one accesses the soot scrapers (6). These (four
per handle) can be slid forwards and backwards, and scrape off the soot between the
smoke tubes. The door (7) is opened with the handle supplied and can be swung up on its
two adjustable hinges. The burner housing (8) is located in the hearth and is accessible
when the door has been opened. It is installed with four screws on the rear of the stove body.
The burner (9) sits loose in the burner housing. The firing element (10) is located in the
burner housing behind the burner. It is the firing element that gives off the heat required to
ignite the pellets. The flame sensor (11) is beside the ignition unit and indicates if there is
flame in the burner or not. The ash box (12) is inset in the bottom of the hearth under the
burner housing. It can be removed when the door has been opened.
The combustion fan (13) is placed on the rear of the burner housing and provides the burner
with air for combustion. The control circuit board (15) is placed inside the stove and contains
a transformer for 12V-voltage to the electronics and control and supervision. The hot air fan
(16) is located inside the stove and sucks air from the rear of the stove, which is then heated
up in the smoke tubes and expelled through the holes in the front.
The pellet hopper (17) has space for 38 litres of pellets, and is filled through the filler hatches
(18). There is a hatch on each side, so that one can place the stove in a corner if one so
wishes. The pellet feeder (19) is below the pellet hopper and consists of a rotating cylinder
with a spiral spring that slowly turns at the bottom of the hopper and prevents blockages.
The patented design means that pellets cannot stick in the feeder. Safety thermostats (20)
are located on the:
1. fall pipe from the pellet feeder (85˚C),
2. the pellet feeder front wall (85˚C) and
3. the flue (204˚C)
Fig. 1
Control card (15)
Pellet feeder (19)
Pellet hopper (17)
Flue (3)
Top (1)
Cleaning hatch (2)
Front (5)
Soot scraper (6)
Door (7)
Ash box (12)
Burner (9)
Filling hatch (18)
Hot air fan (16)
Combustion fan (13)
Firing element (10)
Flame sensor (11)
Burner housing (8)
Safety thermostats (20)
Smoke tubes (4)
Sound trap
Summary of Contents for MYSINGE
Page 1: ...INSTALLATION and OPERATING INSTRUCTIONS PELLET STOVE MYSINGE ...
Page 2: ......
Page 4: ...PELLET STOVE KMP MYSINGE ARITERM SWEDEN AB Installation Instructions 2010 05 20 4 24 ...
Page 20: ...PELLET STOVE KMP MYSINGE ARITERM SWEDEN AB Installation Instructions 2010 05 20 20 24 ...
Page 22: ......
Page 23: ......