INSTALLATION
b Pulse-controlled extinguishing system connected to the water supply system
•
The magnetic valve pipe (5) is connected to the feed auger pipe. The valve is controlled
by the Arimatic automatic control system. The pulse-controlled burn back protector is
adjusted to a temperature of 60 – 70°C, where it operates before the AVTA valve. THE
SETTINGS FOR THE PULSE EXTINGUISHING CAN BE FOUND FROM
THE AUTOMATION SYSTEM
OPERATING INSTRUCTIONS!
.
•
The operation of the magnetic valve during power cuts can be ensured using UPS
equipment.
•
Possible loss of supply pressure can be avoided by installing an expansion tank and pressure
warning gauge (PIA).
•
The sensor of the pulse-controlled burn back system is installed close to the burner head
so that it is tripped first.
•
The pulse-controlled burn back system is no substitute for an AVTA or powder
extinguishing system!