Error codes
Cause
Action
Cause
Action
Error code
Error code
ErrorHI:
The flame sensor has
not detected a flame
during high output.
• Incorrectly adjusted fuel and/or
air amount.
("FeedHI" or "Fan HI")
• The hopper is empty.
• Pellets have jammed in the
feeder.
• The feeder auger does not
rotate.
See Menu.
Fill up the pellets.
Remove pellets from the chute.
Ensure that there are no foreign
objects in the chute.
Check that there are no foreign
objects stuck in the feeder auger.
Check switches and wiring to the
motor.
Replace motor.
ErrorLO:
The flame sensor has
not detected a flame
during low output.
• Incorrectly adjusted fuel and/or
air amount.
("FeedLO" or "Fan LO")
• The hopper is empty.
• Pellets have jammed in the
feeder.
• The feeder auger does not
rotate.
See Menu.
Fill up the pellets.
Remove pellets from the chute.
Ensure that there are no foreign
objects in the chute.
Check that there are no foreign
objects stuck in the feeder auger.
Check switches and wiring to the
motor.
Replace motor.
Powfail.
• Power failure.
Check the electrical connection.
Errign:
The firing element
is not drawing any
power.
• Poor contact to firing element.
• Defective firing element.
Check wiring and connections.
Replace firing element.
ErrSafe:
The flame sensor has
not detected a flame
when the safety coil
has been broken.
• One of the safety thermostats
has deployed.
• One of the hatch switches is
not switched on.
Check the fuel volume, and that
the hot air fan functions. Clean the
convection tubes. Reset by pressing
on the panel.
Ensure that the hatch and door is
properly closed. A weak clicking
noise must be heard when closed.
ErrStart:
The flame sensor has
not detected a flame
during the start-up
phase.
• The hopper is empty.
• Pellets have jammed in the
feeder.
• The feeder auger does not
rotate.
• Incorrectly adjusted starting
dose. (”lgn.dose”)
Fill up the pellets.
Remove pellets from the chute.
Ensure that there are no foreign
objects in the chute.
Check that there are no foreign
objects stuck in the feeder auger.
Check switches and wiring to the
motor.
Replace motor.