3.4 Sweeping
The chimney must be swept twice a year. The flue and its connection and the area
underneath the cleaning hatch must be cleaned at least once between the chimney
sweep’s visits.
1. Open the top panel.
2. Unscrew the knob that locks the ash box.
3. Lift the ash box vertically by both knobs.
4. Vacuum clean the ash from the ash box.
5. Vacuum the horizontal flue all the way to the chimney.
The hole is 50 mm in diameter, sufficiently large for a normal vacuum cleaner hose.
If the flue Drag is installed, the sweeping can be done from the outside.
6. Make sure that the ash hatch is firmly in place after cleaning and tighten the
knob properly.
The chimney must be checked for blockages if unused for a prolonged period.
3.5 Hot air fan
Vacuum cleaning of the fans with a brush nozzle should be carried out a couple of times
annually after removing the side hatch.
Do not forget to pull the plug out
before the side hatch is removed.
1. Open the top panel.
2. Loosen the screw on the top of the side panel.
3. Snap the back of the side panel from the stove’s back plate by prizing back the top and
bottom corners of the side panel.
4. Unhook the panel, out - forwards.
NOTE! When vacuuming the hot air fan, be careful not to damage the long and
vulnerable fan blades.
The fan bearings can start to whistle after operating for some time in a dusty environment.
Rectify this with a drop of oil on both bearings.
3.6 Operating stoppage
If the stove does not start, check first where the fault is located using the fault-tracing
diagram below. If you consider that you have the necessary expertise, rectify the fault as
suggested. If not, or if the fault cannot be located, contact your dealer.
After an unsuccessful start attempt or operating stoppage, the burner crucible
must always be emptied! If there are unburned pellets in the crucible it must not
be emptied into the ash box.