![Ariterm GSM A2 Installation And Operating Instrictions Download Page 4](http://html1.mh-extra.com/html/ariterm/gsm-a2/gsm-a2_installation-and-operating-instrictions_2972150004.webp)
ARITERM GSM A2
ARITERM SWEDEN AB
Installation instructions -
2011.11.24 - Page 4/8
To modify the temperature limit:
Send:
Temp?
?
As a response you get: Temp**1,+053, *2,+240, *3,+053, *4,+050, *5,+053, *
Example: We wish to change the temperature limit to +80 degrees.
Send:
Temp!*4,+080,*
(No spaces)
As a response you get: Temp**1,+053, *2,+240, *3,+053, *4,
+080
, *5,+053, *
Relay 1 (REL-1)
Remote input burner or stove (red-black)
Operate with SMS:
Remote
Relay 1 draws for 5 secs.
Relay 2 (REL-2)
Remote input burner or stove (red-black)
Operate with SMS:
Remote2
Relay 2 draws for 5 secs.
To check the system send SMS
Status?
Response:
Status Ariterm:
Supply 12.26 volt
GSM signal: 4
Temp.In026C
Alarm1 (Msg102) Alarm2 (Msg106)
Other
The unit remembers the last status after the power cut.
The system contains two types of initiations:
Ariterm!!
and
Ariterm!!01
Send SMS
Ariterm!!
at following connection:
Input 1 (Ing1 - COM): Alarm or status changes
Alarm relay from the burner to the stove. (grey-brown)
When the burner or stove is started SMS
Started1(Msg100)
is sent.
When the burner or stove is stopped SMS
Stopped1(Msg101)
is sent.
When the burner or stove stops during operational stoppage SMS
Alarm1(Msg102)
is sent.
Input 2 (Ing2 - COM): Alarm or status changes
Alarm relay from the burner to the stove. (grey-brown)
When the burner or stove is started SMS
Started2(Msg104)
is sent.
When the burner or stove is stopped SMS
Stopped2(Msg105)
is sent.
When the burner or stove stops during operational stoppage SMS
Alarm2(Msg106)
is sent.
Input 3 (Ing3 - COM): Level alarm pellet store
Level alarm fuel. 1350 Capacitive sensor.
If the pellets are missing for more than 10 sec. SMS
Storage Alarm (Msg107)
is sent.
Input 4 (Ing4 - COM): Temperature alarm
5292 Tank sensor.
Settable temperature limit (Tmp4). Factory setting 50˚, setting range 10-90˚.
Sends SMS
TempAlarm (Msg108)
) if the temperature has fallen below the temperature
limit (Tmp4) for more than 5 mins.
At first start: The function is deactivated until the temperature rises above the
temperature limit.